Spectroscopy Instruments
Filter
Showing 1471–1500 of 2630 results
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | NIRQuest+ |
| Spectral Range | 900 nm – 2500 nm |
| Detector | InGaAs linear array |
| Resolution | 3.13 nm FWHM (typical), 5.47 nm FWHM (typical), 6.25 nm FWHM (typical) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms integration |
| >13,000 | 1 @ 1000 ms integration |
| Dynamic Range | 7.5 × 10⁶ (system) |
| 10,000 | 1 (single acquisition) |
| Slit Width | 25 µm |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6 RMS counts @ 100 ms |
| Fiber Connector | SMA 905 |
| Thermoelectric Cooling | -20 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Model | NIRQuest+ (NIRQuest+1.7 / NIRQuest+2.2 / NIRQuest+2.5) |
| Spectral Range | 900 nm – 2500 nm |
| Detector | InGaAs linear array |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| ≥10,000 | 1 @ 100 ms (multiple configurations) |
| Dynamic Range | 7.5 × 10⁶ (system) |
| 10,000 | 1 (single acquisition) |
| Slit | 25 µm |
| Grating Options | GRATING_#NIR1 / #NIR2 / #NIR3 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Cooling | Thermoelectrically cooled to –20 °C |
| Fiber Connector | SMA 905 |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic |
| Model | NIRQuest+ |
| Instrument Type | Portable |
| Operating Principle | Grating-Based Scanning Spectrometer |
| Wavelength Range | 900 nm – 2500 nm |
| Detector | Thermoelectrically Cooled InGaAs Linear Array |
| Slit Width | 25 µm |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Dynamic Range | 7.5 × 10⁴ (system) |
| 10,000 | 1 (single acquisition) |
| Signal-to-Noise Ratio | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Fiber Connector | SMA 905 |
| Order-Sorting Filter | OF1-RG830 Longpass NIR Filter (optional) |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Brand | Ocean Optics |
|---|---|
| Model | NIRQuest+ |
| Detector | InGaAs linear array |
| Wavelength Range | 900 nm – 2500 nm |
| Optical Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Slit | 25 µm |
| Cooling | Thermoelectric to –20 °C |
| Integration Time | 1 ms – 12 s |
| Dark Noise | 6–24 RMS counts (dependent on integration time) |
| Dynamic Range | 7.5 × 10⁴ (system) |
| 10,000 | 1 (single acquisition) |
| SNR | >15,000:1 @ 100 ms |
| >13,000 | 1 @ 1000 ms |
| Dimensions | 182 × 110 × 47 mm |
| Weight | 1.18 kg (without power supply) |
| Fiber Connector | SMA 905 |
| Order-Sorting Filter | OF1-RG830 long-pass NIR filter (optional) |
| Grating Options | GRATING_#NIR1, GRATING_#NIR2, GRATING_#NIR3 |
| Spectral Configuration Options | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory |
| Optical Principle | Fixed-grating array-detector non-scanning spectrometer |
| Wavelength Ranges | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Detector | InGaAs linear array (TE-cooled) |
| Resolution | 1.7–4.0 nm FWHM (configuration-dependent) |
| Integration Time | 1 ms to 65 s |
| Interface | USB 3.0 or Ethernet (optional) |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (with compliant software stack) |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NIRQuest+ |
| Instrument Type | Laboratory & Process-Ready |
| Optical Principle | Fixed-grating spectrometer with linear array detector (non-scanning) |
| Wavelength Ranges | NIRQuest+1.7 (900–1700 nm), NIRQuest+2.2 (900–2200 nm), NIRQuest+2.5 (900–2500 nm) |
| Detector | InGaAs linear array (TE-cooled) |
| Optical Resolution (FWHM) | 1.7–5.0 nm (configurable by slit and grating) |
| Integration Time | 1 ms to 65 s |
| Signal-to-Noise Ratio | ≥15,000:1 (at full signal, 1 s integration, NIRQuest+2.5) |
| Dynamic Range | >25,000:1 (with 16-bit ADC) |
| Interface | USB 2.0 / USB 3.0 (via optional adapter) |
| Compliance | CE, RoHS, FCC Class B |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | NIRQuest+1.7, NIRQuest+2.2, NIRQuest+2.5 |
| Spectral Range | 900 nm – 2500 nm |
| Detector | InGaAs (TE-cooled) |
| Resolution (FWHM) | 3.13 nm (typ.), 5.47 nm (typ.), 6.25 nm (typ.) |
| Integration Time | 1 ms – 200 ms (NIRQuest+2.5), 1 ms – 1 s (NIRQuest+2.2), 1 ms – 120 s (NIRQuest+1.7) |
| SNR | 13,000:1 (typ., NIRQuest+1.7), 10,000:1 (typ., NIRQuest+2.2) |
| Slit Width | 25 µm |
| Dimensions | 182 × 110 × 47 mm³ |
| Weight | 1.18 kg (instrument only) |
| Cooling | Thermoelectric to –20 °C |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Model | Ocean HDX |
| Spectral Range | 200–925 nm |
| Detector | Back-Illuminated Thin CCD |
| Resolution | 0.61–0.72 nm FWHM (with 10 µm slit) |
| Signal-to-Noise Ratio | 400:1 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.05% (typical, 3 AU at 600 nm) |
| A/D Conversion | 16-bit |
| Integration Time | 6 ms – 10 s |
| Thermal Stability | ±1 pixel over 0–40 °C |
| f/# | f/4 |
| Onboard Memory | Up to 50,000 spectra |
| I/O | 8 programmable digital I/O lines |
| Communication Interfaces | USB 2.0, Gigabit Ethernet, Wi-Fi 802.11n, SPI, RS-232 |
| Operating Temperature | 0–40 °C |
| Dimensions | 88.9 × 63.5 × 52.4 mm |
| Weight | 400 g |
| Brand | Ocean Optics |
|---|---|
| Origin | Imported |
| Model | Ocean HDX |
| Spectral Range | 200–925 nm |
| Detector Type | CCD |
| Optical Resolution (FWHM) | 0.61–0.72 nm (with 10 µm slit) |
| Signal-to-Noise Ratio | 400:1 |
| Dynamic Range | 12,000:1 |
| Stray Light | < 0.3% (typical, at 600 nm with 400 nm cutoff filter) |
| Onboard Storage Capacity | Up to 50,000 spectra |
| Interface Options | USB 3.0, Gigabit Ethernet, Wi-Fi (802.11ac), RS-232 |
| Operating Temperature Stability | ±0.05 nm/°C (wavelength drift) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Ocean HR2 |
| Spectral Range | 190–1150 nm (configurable) |
| Detector Type | CCD |
| Optical Resolution | <1.0 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 380:1 (single-scan @ 10 ms integration time) |
| Dynamic Range | 2.46 × 10⁸ (system-level) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Ocean Optics Ocean HR2 |
| Spectral Range | 190–1150 nm (configurable) |
| Detector Type | CCD |
| Optical Resolution | <1.0 nm FWHM (configuration-dependent) |
| Sensitivity | 380:1 (single-scan @ 10 ms) |
| System Dynamic Range | 2.46 × 10⁸ |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ocean HR4 |
| Price | Upon Request |
| Spectral Range | 220–1050 nm (configurable by grating and slit) |
| Optical Resolution (FWHM) | 0.13–1.16 nm (dependent on optical configuration) |
| Signal-to-Noise Ratio | 3000:1 (in high-speed averaging mode) |
| Dynamic Range | 1300:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ocean HR6 |
| Spectral Range | ~185–1100 nm |
| Optical Resolution | <1.0 nm FWHM (configurable, e.g., with 25 µm slit) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Ocean SR4 |
| Detector Type | 3648-pixel CCD linear array |
| Spectral Range | 190–1100 nm (configurable) |
| Optical Resolution (25 µm slit) | 1.36–1.65 nm (FWHM) |
| Signal-to-Noise Ratio | 3000:1 (per second, High-Speed Averaging Mode) |
| Dynamic Range | 1370:1 (single scan) |
| Integration Time | 3.8 ms – 10 s |
| Stray Light | < 2.3 AU |
| Thermal Wavelength Stability | 0.05 pixels/°C |
| Scan Rate | 74 spectra/s |
| ADC | 16-bit |
| Trigger Modes | External TTL, Software, Hardware Synchronization |
| Interface | USB 3.2 Gen 1 (Type-B connector, TFM-108-02-L-DH compliant) |
| Dimensions | 88.1 × 63.5 × 31.4 mm |
| Weight | 254 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Detector Type | CCD |
| Model | Ocean SR4 |
| Spectral Range | 190–1100 nm (configurable) |
| Optical Resolution (25 µm slit) | 1.36–1.65 nm (FWHM) |
| Signal-to-Noise Ratio | 3000:1 (per second, High-Speed Averaging Mode) |
| Dynamic Range | 1370:1 (single scan) |
| Integration Time | 3.8 ms – 10 s |
| Stray Light | 2.3 AU |
| Scan Rate | 74 scans/s |
| Thermal Wavelength Stability | 0.05 pixels/°C |
| A/D Conversion | 16-bit |
| Trigger Modes | External, Internal, Software, Level, Edge |
| Interface | USB-C (USB 2.0 compliant) |
| Dimensions | 88.1 × 63.5 × 31.4 mm |
| Weight | 254 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Ocean SR6 |
| Detector Type | CCD |
| Spectral Range | ~185–1100 nm (configuration-dependent) |
| Optical Resolution (25 µm slit) | 0.50–2.0 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single-scan) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean SR6 |
| Detector Type | CCD |
| Spectral Range | ~185–1100 nm (configuration-dependent) |
| Optical Resolution (25 µm slit) | 0.50–2.0 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | 3500:1 (on-board averaging mode) |
| Dynamic Range | 12,000:1 (single-scan) |
| Integration Time | 7.2 ms – 5 s |
| Thermal Stability | 0.02 nm/°C |
| Pixel Count | 2048 |
| Interface | USB Type-C, SMA 905, 16-pin Samtec TM, RS-232 |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −30–70 °C |
| Dimensions | 89.0 × 63.5 × 31.3 mm |
| Weight | 275 g |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Ocean ST |
| Spectral Range | 185–650 nm (UV-VIS), 350–810 nm (VIS-NIR), 645–1085 nm (NIR) |
| Optical Resolution | 2.2 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | >250:1 (full-scale, single-scan, typical) |
| Dynamic Range | 1000:1 (single-scan) |
| Stray Light | <0.2% at 600 nm (typical) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean ST |
| Spectral Range | 185–650 nm (UV-Vis) |
| Optical Resolution | 2.2 nm FWHM (configuration-dependent) |
| Signal-to-Noise Ratio | >250:1 (full well, typical) |
| Dynamic Range | 1000:1 (single-scan) |
| Stray Light | <0.2% at 600 nm |
| Detector | Back-thinned CMOS linear array |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | Ocean ST |
| Spectral Range | 185–650 nm (UV-VIS), 350–810 nm (VIS-NIR), 645–1085 nm (NIR) |
| Optical Resolution (FWHM, 25 µm slit) | 2.2 nm |
| Signal-to-Noise Ratio | 190:1 (single scan @ 10 ms), 2250:1 (1 s averaging, no buffer) |
| Dynamic Range | 1000:1 (single scan) |
| Stray Light | < 2.0 AU |
| Integration Time | 3.8 ms – 6 s |
| Scan Rate | 160 Hz (no buffer) |
| A/D Resolution | 14-bit |
| Thermal Stability | 0.05 pixel/°C |
| Interface | USB-C + 16-pin Samtec TFM-108-02-L-DH connector |
| Dimensions | 42.1 × 40.3 × 26.6 mm |
| Weight | 70.4 g |
| Brand | Ocean Optics |
|---|---|
| Model | Ocean-FX |
| Spectral Range | 200–1100 nm |
| Optical Resolution | 0.8 nm (FWHM) |
| Detector | Hamamatsu S11639 CMOS |
| Slit Options | 5, 10, 25, 50, 100, or 200 µm (SMA 905 or FC connector) |
| Signal-to-Noise Ratio (single scan) | ~270:1 |
| Dynamic Range (single scan) | ~6400:1 |
| Integration Time | 10 µs – 10 s |
| Maximum Scan Rate | 3000 scans/s (host-dependent) |
| Stray Light | <0.08% at 600 nm |
| Thermal Drift | 0.11 pixels/°C |
| Onboard Buffer | 50,000 spectra with timestamping |
| Connectivity | Gigabit Ethernet, Wi-Fi 802.11n, USB 3.0 |
| Brand | Ocean Optics |
|---|---|
| Model | Ocean-FX |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.8 nm (with 600 l/mm grating & 5 µm slit) |
| Detector | Hamamatsu S11639 CMOS |
| Slit Options | 5, 10, 50, 100, or 200 µm (SMA 905 or FC connector) |
| Sensitivity | Optimized for 200–1025 nm with 25 µm slit |
| Signal-to-Noise Ratio (single scan) | ~270:1 |
| Dynamic Range (single scan) | ~6400:1 |
| Stray Light | <0.08% at 600 nm |
| Integration Time | 10 µs to 10 s |
| Maximum Scan Rate | 3000 spectra/s (host-dependent) |
| Thermal Drift | 0.11 pixels/°C |
| Onboard Memory | 50,000 spectra with timestamping |
| Connectivity | Gigabit Ethernet, Wi-Fi 802.11ac, USB 3.0 |
| Brand | Ocean Optics |
|---|---|
| Model | Ocean-FX |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.8 nm (with 600 l/mm grating & 5 µm slit) |
| Detector | Hamamatsu S11639 CMOS |
| Sensitivity | Optimized for 200–1025 nm with 25 µm slit |
| Signal-to-Noise Ratio (SNR, single scan) | ~270:1 |
| Dynamic Range (single scan) | ~6400:1 |
| Stray Light | <0.08% at 600 nm |
| Minimum Integration Time | 10 µs |
| Onboard Buffer | 50,000 spectra with timestamping |
| Scan Rate | Up to 4500 scans/s (system-dependent) |
| Slit Options | 5, 10, 50, 100, or 200 µm |
| Input Connector | SMA 905 or FC |
| Thermal Drift | 0.11 pixels/°C |
| Communication Interfaces | Gigabit Ethernet, Wi-Fi 802.11n, USB 3.0 |
| Brand | Ocean Optics |
|---|---|
| Model | QE Pro |
| Detector Type | Back-Illuminated CCD |
| Spectral Range | Configurable from 185–1100 nm |
| Resolution | 18-bit digitization |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (full well) |
| Dynamic Range | 85,000 (typical, single acquisition) |
| Stray Light | <0.08% at 600 nm |
| Onboard Memory Buffer | Yes |
| Optional Integrated Mechanical Shutter | Yes |
| Interchangeable Slit Options | Yes |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE Pro High-Performance Spectrometer |
| Detector Type | Back-Thinned CCD |
| Optical Resolution (FWHM) | Configurable from 0.14 nm to 10 nm (dependent on grating and slit) |
| Wavelength Range | 200–1100 nm (model-dependent configurations) |
| Signal-to-Noise Ratio | Up to 80,000:1 (at full signal, 10 s integration) |
| Dynamic Range | >85,000:1 (with 15,000-spectrum onboard memory buffer) |
| Integration Time | 8 ms – 60 s |
| Thermoelectric Cooling | Down to –15 °C below ambient |
| Interface | USB 3.0 |
| Compliance | CE, RoHS, FDA 21 CFR Part 11 ready (via OceanView software configuration) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Detector Type | Back-Illuminated FFT-CCD |
| Spectral Range | UV-VIS-NIR (configurable from 200–1100 nm) |
| Resolution | 1.2–6.87 nm FWHM (model-dependent) |
| Bit Depth | 18-bit |
| Peak Quantum Efficiency | 90% |
| Signal-to-Noise Ratio | 1000:1 (single acquisition) |
| Dynamic Range | 85,000:1 (typical) |
| Stray Light | <0.08% at 600 nm |
| Integration Time | 8 ms – 3600 s |
| Dark Noise | 2.5 counts RMS |
| Linearity | ±0.5% nonlinearity |
| Operating Temperature | 0–50 °C |
| Dimensions | 182 × 110 × 47 mm³ |
| Weight | 1.15 kg |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | QE Pro Raman+ |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 150 cm⁻¹ – 4000 cm⁻¹ |
| Spectral Resolution | 0.42 nm (FWHM, typical) |
| Detector | TE-cooled 1044 × 64-pixel back-thinned FFT-CCD |
| Quantum Efficiency | 90% (peak) |
| Signal-to-Noise Ratio | 1000:1 (single acquisition) |
| Integration Time | 8 ms – 3600 s |
| Dynamic Range | ~85,000:1 |
| Optical Interface | SMA 905 |
| Onboard Memory | 15,000 spectra |
| Dimensions | 182 mm × 110 mm × 47 mm |
| Weight | 1.15 kg (instrument only) |
| Power Supply | 0.45 kg |
| Operating Temperature | 0 °C – 50 °C |
| Humidity | ≤90% RH (non-condensing) |
| Communication | USB 2.0 (480 Mbps, USB 1.1 compatible), RS-232 |
| Brand | Ocean Optics |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | QE Pro Raman+ |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 150 cm⁻¹ – 4000 cm⁻¹ |
| Spectral Resolution | 0.42 nm (FWHM, typical) |
| Detector | TE-cooled 1044 × 64-pixel back-thinned FFT-CCD |
| Quantum Efficiency | 90% (peak) |
| Signal-to-Noise Ratio | 1000:1 (single acquisition) |
| Integration Time | 8 ms – 3600 s |
| Dynamic Range | ~85,000:1 |
| Optical Interface | SMA 905 |
| Onboard Memory | 15,000 spectra |
| Communication | USB 2.0 (480 Mbps), RS-232 |
| Dimensions | 182 mm × 110 mm × 47 mm |
| Weight | 1.15 kg (instrument only) |
| Power Supply | 0.45 kg |
| Operating Temperature | 0 °C – 50 °C |
| Humidity | ≤90% RH (non-condensing) |
| Slit Options | 25 µm, 50 µm |
| Grating | Custom holographic grating (e.g., GRATING_#H6) |
| Excitation Wavelengths | 532 nm, 638 nm, or 785 nm (preconfigured) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE65 Pro |
| Spectral Range | 200–1100 nm |
| Detector | Back-Illuminated CCD (Hamamatsu FFT-CCD) |
| Optical Resolution (FWHM) | 0.14–7.7 nm |
| Sensitivity | 22 e⁻/count (all λ) |
| Signal-to-Noise Ratio | 1000:1 (full signal) |
| Dynamic Range | 7.5 × 10⁹ |
| Stray Light | <0.08% @ 600 nm |
| Cooling | Two-stage TEC to –15 °C (ΔT = –40 °C below ambient) |
| Integration Time | 8 ms – 15 min |
| Slit | Interchangeable SMA905-compatible slit |
| Grating Options | Including 900 grooves/mm (#H36), blaze 500 nm |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | QE65 Pro Research-Grade Spectrometer |
| Detector | Hamamatsu S7031-1006 back-illuminated CCD |
| Quantum Efficiency | up to 90% |
| Cooling | TEC-controlled, down to −15 °C |
| Spectral Range (configurable) | 200–950 nm or 350–1100 nm |
| Slit Options | Interchangeable SMA905-mount slits |
| Stray Light Rejection | Enhanced via optimized grating and optical design |
| Signal-to-Noise Ratio | 1000:1 (full signal, 1 s integration) |
| Thermal Wavelength Stability | <0.005 nm/°C |
| Trigger Interface | TTL-compatible hardware trigger input/output |