Spectroscopy Instruments
Filter
Showing 1621–1650 of 2629 results
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G2301 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Simultaneous Target Gases | CO₂, CH₄, H₂O |
| Detection Sensitivity | <0.5 ppb (CH₄), <70 ppb (CO₂), <80 ppm (H₂O) |
| Precision (1σ, 5 s) | CO₂ <70 ppb, CH₄ <0.5 ppb, H₂O <80 ppm |
| Precision (1σ, 5 min) | CO₂ <25 ppb, CH₄ <0.22 ppb, H₂O <30 ppm |
| Max Drift (24 h, STP) | CO₂ <120 ppb, CH₄ <1 ppb, H₂O <100 ppm |
| Water Vapor Correction | Automatic dry-mole-fraction reporting |
| Operating Pressure Range | 300–1000 Torr (40–133 kPa) |
| Sample Flow Rate | <0.4 SLM at 760 Torr |
| Temperature Control Stability | ±0.005 °C (cavity) |
| Pressure Control Stability | ±0.0002 atm (cavity) |
| Sample Temp. Range | −10 to +45 °C |
| Ambient Temp. Range (operational) | 10 to 35 °C |
| Data Interfaces | RS-232, Ethernet, USB, analog (0–10 V optional) |
| Dimensions (Analyzer) | 43.2 × 17.8 × 44.5 cm (W×H×D) |
| Weight | 26.9 kg (incl. external pump) |
| Power | 100–240 VAC, 47–63 Hz, <375 W peak |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P200 |
| Optical Design | Single-Beam |
| Light Source | Pulsed Xenon Lamp |
| Detector | 2048-Pixel CCD Array |
| Wavelength Range | 220–950 nm |
| Spectral Bandwidth | 5 nm |
| Wavelength Repeatability | ±1 nm |
| Photometric Linearity | <1% at 546 nm |
| Absorbance Accuracy | ±0.003 A |
| Absorbance Range | –2 to 2 A (extended to –22 A.U. with digital offset compensation) |
| Minimum Sample Volume | 2 µL |
| Pathlength | 1 mm (capillary tip mode) or 10 mm (cuvette mode) |
| Measurement Time | ≤3 seconds per full-spectrum scan |
| Dimensions | 26 × 39 × 10 cm |
| Weight | 4.2 kg |
| Data Interfaces | USB, Bluetooth, SD card |
| Output Options | Onboard thermal printer (optional), PC export via Picodrop Analysis Software |
| DNA Quantification Range | 0.4–1200 ng/µL |
| BSA Quantification Range (Direct UV) | 0.02–25 mg/mL |
| OD₆₀₀ Mode | Enabled |
| Kinetic Assay Support | Yes (time-resolved absorbance series) |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 160-1900 |
| Type | Laboratory-Scale IR Sample Preparation Accessory |
| Material | Hardened Stainless Steel |
| Sample Diameter | 13 mm |
| Vacuum Interface | Standard Negative-Pressure Port |
| Includes | Stainless Steel Base with Vacuum Port, 13 mm Die Cavity, Two Polished Pressure Anvils, Precision-Machined Plunger, Two O-Rings (for Plunger Seal and Base Mounting) |
| Surface Finish | Mirror-Polished Contact Surfaces |
| Compliance | Designed for ASTM E1252 and USP <1119> FTIR Sample Preparation Protocols |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 160-8010 |
| Purity | Spectroscopic Grade |
| Form | Fine Crystalline Powder |
| Packaging | 100 g Bottle |
| Application | FTIR Sample Preparation (Transmission Pellet & DRIFTS Background) |
| Compliance | Meets ASTM E1421 and ISO 18387 specifications for IR-transparent matrix materials |
| Storage | Desiccated, Room Temperature |
| Hygroscopicity | High — Requires Handling in Dry Atmosphere (<10% RH) |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 16x-xxx (Compatible with TL011-1000 configuration) |
| Mounting Interface | Universal FTIR Beam Port |
| Incident Angle | 30° ± 0.5° |
| Sample Holder Options | 3/8", 1/4", and 3/16" diameter sample caps |
| Optical Path | Fixed-angle, non-adjustable specular geometry |
| Compatibility | Bruker Tensor, Thermo Nicolet iS Series, PerkinElmer Frontier, Agilent Cary 630/670, Shimadzu IRTracer, and domestic FTIR systems with standard KBr beam path exit |
| Material | Gold-coated aluminum mirror optics (R > 98% @ 4000–400 cm⁻¹) |
| Weight | 185 g |
| Dimensions (L×W×H) | 82 × 54 × 32 mm |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | P042-1000 |
| Compatibility | Varian, Shimadzu, Bruker, PerkinElmer FTIR spectrometers |
| Mounting | Base-mounted |
| Optical Design | Monolithic mirror construction |
| Adjustment | Micrometer-driven sample cup positioning |
| Performance | Optimized infrared beam path for high throughput and signal-to-noise ratio |
| Optional Variants | Gold-coated, NIR-specific, external large-sample, heated, and automated multi-sample versions |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 16XX-XX |
| Instrument Type | Laboratory FTIR Accessory |
| FTIR Spectral Range | 7800–400 cm⁻¹ |
| Optical Resolution | 0.5 cm⁻¹ |
| Scan Speed | 1 scan/sec |
| Signal-to-Noise Ratio | 15,000:1 |
| Temperature Control Range | Ambient to 200 °C |
| Window Material Options | CaF₂, BaF₂, ZnSe, KBr, CsI (selected per spectral region) |
| Window Dimensions | Ø32 mm × 3 mm thick |
| Clear Aperture | 13 mm diameter |
| Pathlength Options | Fixed via precision-machined metal spacers (e.g., 0.025 mm, 0.1 mm, 0.5 mm, 1.0 mm) |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Configuration | Universal Mounting Interface for FTIR Spectrometers |
| Mirror Coating | Electroless Gold (Au) |
| Incident Angle | 80° ± 0.5° |
| Polarization Capability | Manual Rotatable Polarizer Holder |
| Compatibility | Bruker, Shimadzu, Thermo Fisher Scientific, PerkinElmer, Varian (Agilent) FTIR Platforms |
| Optical Path | Fixed-geometry, Non-Imaging Grazing Incidence Beam Path |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Cell Volume | 38.5 mL |
| Path Length | 100 mm |
| Max Operating Temperature | 260 °C |
| Maximum Pressure Rating | 100 psi |
| Construction | Stainless Steel Body with O-ring Seals |
| Window Mounting | 38 × 6 mm Rectangular Aperture (Windows Not Included) |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Type | Manual or Motorized Polarizer |
| Mounting Format | Standard 2" × 3" Spectroscopy Sample Holder |
| Clear Aperture | Ø20 mm |
| Total Diameter | Ø25 mm |
| Angular Accuracy (Manual) | ±2° |
| Angular Accuracy (Motorized) | ±0.5° |
| Compatibility | Universal with FTIR spectrometers (including Pike ATR, 80° Mirror, Grazing Angle Accessories) |
| Control Interface | Manual rotation or RS-232/USB motorized positioning |
| Software Integration | AutoPRO™ for automated polarization-resolved spectral acquisition |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Optical Path Length Options | Fixed (2.4 m, 10 m, 22 m, 33 m) or Variable (1–16 m) |
| Temperature Control Range | –200 °C to +200 °C (±1.0 °C stability) |
| Window Materials | BaF₂, CaF₂, KBr, KRS-5, NaCl, ZnSe |
| Mirror Coating | Gold-coated stainless steel |
| Compatible FTIR Systems | Thermo Nicolet, Bruker Tensor/Vertex, Shimadzu IRTracer, Varian Excalibur |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Compatibility | Universal for 13 mm KBr pellets and thin films ≤ 0.5 mm thickness |
| Construction | Steel base plate with precision-machined alignment pins + magnetic stainless-steel cover plate |
| Application | FTIR transmission mode only |
| Mounting | Standard 25.4 mm (1") optical post or benchtop fixture |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Optical Path Length | 100 mm |
| Construction | Borosilicate Glass Body with Precision-Machined Aluminum Ring and Mounting Frame |
| Compatible Window Material | 25 mm × 4 mm (Thickness) IR-Transmissive Windows (e.g., KBr, ZnSe, CaF₂) |
| Mounting Interface | Standard FTIR Sample Compartment Compatibility (e.g., Thermo Nicolet, Bruker, PerkinElmer) |
| Brand | Pike Technologies |
|---|---|
| Material Options | KBr, ZnSe, CaF₂ |
| Diameter Options | 13–50 mm (standard increments) |
| Surface Quality | λ/4 @ 633 nm |
| Parallelism | < 10 arcsec |
| Coating | Optional AR coating (3–12 µm broadband) |
| Compliance | ASTM E1421-22 (IR Spectroscopy Calibration Standards), ISO 17025 traceable manufacturing |
| Packaging | Cleanroom-sealed, desiccated blister packs |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 16x-xxx |
| Pricing | Available Upon Request |
| Brand | Pike Technologies |
|---|---|
| Origin | USA |
| Model | TL160-1133 |
| Compatible Cell Type | Gas & Liquid Transmission Cells |
| Window Material | Potassium Bromide (KBr) |
| Dimensions | 25 mm × 4 mm |
| Application | Dry Gas & Anhydrous Liquid IR Analysis |
| Compliance | ASTM E1421, ISO 18387, USP <1119> |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 16x-xxx |
| Pricing | Available Upon Request |
| Brand | PIKE |
|---|---|
| Origin | USA |
| Model | 16x-xxx |
| Angle Range | 30°–80° (continuously adjustable) |
| Mounting | Pin-locating base compatible with Varian, Shimadzu, Bruker, Thermo Fisher, and PerkinElmer FTIR spectrometers |
| Configuration | External sample stage for large-format specimens |
| Optional Upgrade | Motorized angle control with PC interface for automated angular scans |
| Compliance | Designed to meet ISO 17025-aligned measurement practices for reflectance spectroscopy |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PINPOINTER |
| Instrument Type | Portable/Handheld Raman Spectrometer |
| Spectral Range | 200–3300 cm⁻¹ |
| Spectral Resolution | 13 cm⁻¹ @ 1000 cm⁻¹ |
| Spatial Resolution | Lateral 105 µm, Axial 200 µm |
| Minimum Wavenumber Shift | <0.1 nm |
| Spectral Repeatability | 13 cm⁻¹ @ 1000 cm⁻¹ |
| Excitation Wavelength | 785 nm |
| Laser Power | 5–300 mW |
| Wavelength Stability | <1 cm⁻¹ over 12 h |
| Photometric Stability | <4% over 12 h |
| Optical NA | 0.22 |
| Sample Spot Size | 0.1–0.3 mm |
| Power Supply | Rechargeable battery, >4 h runtime per charge |
| Dimensions | 216 × 109 × 64 mm (8.5" × 4.3" × 2.5") |
| Weight | 1.36 kg (3 lbs.) |
| Operating Temperature | −25 °C to +45 °C |
| Brand | PerfectLight |
|---|---|
| Model | PLS-SXE300UV |
| Light Source Type | Xenon Arc Lamp-Based Solar Simulator |
| Optical Architecture | Single-Beam |
| Detector | Photodiode Array |
| Spectral Range | 320–780 nm (extendable to 2500 nm with optional filters) |
| Wavelength Control | Motorized Auto-Scanning |
| Total Output Power | 50 W |
| Beam Divergence | Avg. 6° |
| Illuminated Spot Diameter | 30–60 mm (distance-dependent) |
| Long-Term Irradiance Stability | ≤ ±3% over 8 h |
| Lamp Power Rating | 300 W (adjustable 150–300 W) |
| Lamp Lifetime | >1000 h (under standard photocatalytic operating conditions) |
| Trigger System | Integrated High-Voltage Ignition (dual-stage, no external HV cabling) |
| Current Limit | 21 A |
| Thermal Management | Passive Heatsink (large-area aluminum fin array) |
| EMI Shielding | Enclosed metal lamp housing |
| Control Interface | Microprocessor-based digital power management with programmable operation mode |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | IR4 |
| Instrument Type | Laboratory-Scale Infrared Auxiliary Detector |
| Wavenumber Range | 3500–2500 cm⁻¹ |
| Resolution | 1 cm⁻¹ |
| Scan Speed | 12 scans/sec |
| Signal-to-Noise Ratio | 1000 |
| Flow Cell Volume | 13 µL |
| Maximum Pressure | 50 bar |
| Operating Temperature (Flow Cell & Transfer Line) | Up to 170 °C |
| Detection Modes | Concentration, Reference, Compositional (CH₃/1000C), Carbonyl (C=O/1000C) |
| Sensitivity (Concentration) | >0.3 AU·mL/mg |
| Compositional LOD | 5 CH₃/1000TC |
| Carbonyl LOD | 5 C=O/1000TC |
| Detector Noise | <1×10⁻³ AU |
| Analog Output | Four single-ended, 16-bit, 0–2.5 V / 0–10 V |
| Digital Input | TTL |
| Communication Interface | RS-232 |
| Power Supply | 90–260 VAC, 50–60 Hz |
| Control Unit Dimensions (W×H×D) | 19×6×25 cm, 4 kg |
| Spectral Unit Dimensions (W×H×D) | 15×12×9 cm, 2 kg |
| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | PolyPen Aqua PA210 |
| Spectral Range (UVIS) | 380–790 nm |
| Spectral Range (NIR) | 640–1050 nm |
| Optical Resolution (FWHM) | 8 nm |
| Stray Light | −30 dB |
| Optical Aperture | 7 mm |
| Measurement Chamber Volume | 4 mL |
| Light Source | Pulsed Xenon Lamp |
| OD Wavelengths (UVIS) | 600, 680, 735, 750 nm |
| OD Wavelengths (NIR) | 680, 735, 750 nm |
| Display | 240 × 320 px TFT touchscreen (65,535 colors) |
| Onboard Memory | 16 MB (≥4,000 spectra) |
| ADC | 16-bit |
| Dynamic Range | 1:4,300 (high gain), 1:13,000 (low gain) |
| Scan Time | ~100 ms per spectrum |
| GPS Accuracy | <1.5 m (CE-certified module) |
| Dimensions | 150 × 75 × 40 mm |
| Weight | 300 g |
| Enclosure | IP54-rated splash-resistant housing |
| Battery | Rechargeable 2600 mAh Li-ion (USB charging) |
| Operating Time | Up to 48 h continuous measurement |
| Operating Temp. | 0–55 °C |
| Storage Temp. | −10–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | PoolDirect 9-in-1 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PoolDirect |
| Pricing | Available Upon Request |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 1600 |
| Price | Upon Request |
| Wavelength Range | 325–1100 nm |
| Wavelength Repeatability | ≤1 nm |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 2 nm |
| Stray Light | ≤0.4% T |
| Optical System | Single-Beam with 1200 lines/mm Holographic Grating |
| Display | Large Backlit LCD (Wavelength Resolution: 1 nm) |
| Data Storage | Up to 100 calibration curves and 2000 measurement records |
| Interface | RS-232, USB flash drive support, Bluetooth 4.2 (for data export, mobile app sync, and optional thermal printer) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PPM150 |
| Price Range | USD 2,700 – 6,800 |
| Light Sources | 9 high-stability LEDs |
| Wavelengths | 380, 430, 470, 500, 520, 560, 610, 700, 810 nm |
| Absorbance Range | −0.5 to 4.0 AU |
| Photometric Accuracy | ±1.5% of reading |
| Absorbance Precision | ±0.03 AU |
| Wavelength Accuracy | ±2 nm |
| Sample Cell | 16 mm round cuvette with light-blocking cap |
| Display | 128 × 64 pixel backlit monochrome LCD (60 × 40 mm) |
| Data Storage | 1,000 measurement records (date/time/wavelength/reagent/method/result/test ID) |
| Calibration Curves | Up to 150 preloaded or user-defined methods |
| Communication | IrDA infrared interface |
| Power Supply | 4 × AA rechargeable or alkaline batteries |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Sensor Type | Back-illuminated, fully depleted silicon CCD |
| Pixel Format | 1340 × 100 (HR/LD) or 1340 × 400 (HR/LD) |
| Pixel Size | 20 × 20 µm |
| QE | 75% @ 1000 nm (HR), optimized dark current < 0.0005 e⁻/pix/s (LD) |
| Readout Speed | Up to 32 MHz dual-ADC (HR), 16 MHz (LD) |
| Spectral Acquisition Rate | Up to 1650 spectra/s (continuous), 215 kHz (kinetics mode, HR only) |
| Cooling | ArcTec™ multi-stage thermoelectric cooling |
| Interface | USB 3.0 (5 Gb/s), optional fiber-optic USB extender (50 m) |
| Software | LightField 64-bit with PICAM SDK, IntelliCal wavelength & intensity calibration, LabVIEW/MATLAB/EPICS compatibility |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Model | FER-SCI-BRX, FER-SCI-BX |
| Focal Length | 80.8 mm |
| Aperture | f/4 |
| Spectral Resolution (full focal plane) | 0.20–0.24 nm |
| Wavelength Range | UV-NIR (200–1100 nm) and VIS-NIR (400–1100 nm) |
| Grating Options | 295, 600, 1200 g/mm (interchangeable single-grating turret) |
| Slit Widths | 10–500 µm (laser-cut, height 3.3 mm) |
| CCD Type | Back-illuminated, deep-depletion, frame-transfer architecture with eXcelon and UV coating |
| Sensor Format | 1024 × 256 active + 1024 × 256 storage (total 1024 × 512) |
| Peak Quantum Efficiency | 95% |
| Cooling | Thermoelectric to −60 °C |
| Read Noise | 10 e⁻ rms @ 1 MHz |
| Integration Time | Up to 40 minutes (FER-SCI-BRX), several hours (FER-SCI-BX) |
| Spectral Acquisition Rate | 292 fps (FVB mode, FER-SCI-BRX), 124 fps (FVB mode, FER-SCI-BX) |
| Kinetic Mode Speed | >10,000 spectra/s (10-row binning, FER-SCI-BRX), >5,000 spectra/s (10-row binning, FER-SCI-BX) |
| Wavelength Accuracy | 0.26 nm |
| Repeatability | 0.13 nm |
| Spatial Resolution | 38.5 lp/mm @ 50% contrast (Nyquist-limited, full focal plane) |
| Line Transfer Speed | Adjustable 5.6–35 µs/line (FER-SCI-BRX), 15.2–95 µs/line (FER-SCI-BX) |
| Nonlinearity | <1% @ 1 MHz |
| Gain Options | 1.5 or 3 e⁻/ADU |
| Interface | USB 3.0 (3 m cable included) |
| I/O | Three MCX coaxial ports (2 trigger outputs, 1 trigger input), onboard programmable timing generator |
| Software | 64-bit LightField with real-time processing engine, IntelliCal lamp integration for automated wavelength and intensity calibration |
| Brand | Princeton Instruments (Teledyne) |
|---|---|
| Origin | USA |
| Model | IsoPlane81-BRX/BX-VR, IsoPlane81-BRX-UR |
| Spectral Range | 200–1100 nm |
| Focal Length | 80.0 mm |
| f-number | f/4 |
| Spectral Resolution (FWHM) | 0.1 nm |
| Slit Width | 10–500 µm |
| Sensor Format | 1024 × 256 |
| Cooling | Thermoelectric to –45 °C |
| Peak Quantum Efficiency | >95% (up to >97% with eXcelon™) |
| Interface | USB 3.0 |
| Grating Options | 150–4320 g/mm |
| Optical Coating | Protected silver |
| Brand | Princeton Instruments / Teledyne Princeton Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Models | SP2150, SP2300, SP2500, SP2750 |
| Pricing | Upon Request |