Spectroscopy Instruments
Filter
Showing 151–180 of 1322 results
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1800 |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1800PC |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning | Motorized Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | UV-1900 |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | Onboard memory for 240 calibration curves (240 data points per curve) |
| Data Export | USB 2.0 × 2 (for printer & PC transfer), USB 1.0 for firmware update |
| Software | AOE Basic Spectroscopy Suite (certified under PRC Copyright Registration No. 2021SRxxxxxx) |
| Compliance | ISO 9001:2015, CE Marking, CMC License (PRC Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | UV-1900PC |
| Price Range | USD 2,800–4,200 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Motorized Auto-Scan |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T at 360 nm |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | Onboard memory for 240 calibration curves (240 data points per curve) |
| Data Export | USB 2.0 port for direct U-disk export |
| Printing Interface | PCL-compatible USB printer support (A4 format) |
| Firmware Upgrade | USB-based one-click update via AOE official website (instrument serial number required) |
| Certifications | ISO 9001:2015, CE (EN 61010-1, EN 61326-1), CMC (China Metrology Certification), RoHS Directive 2011/65/EU |
| Software Compliance | Basic Control Software registered with the National Copyright Administration of the People’s Republic of China (Certificate No. 2021SRXXXXXX) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1000 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1020 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | V-1200 |
| Price Range | USD 1,400–2,800 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1020 nm |
| Wavelength Scanning | Motorized Auto-Scan |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.0 nm |
| Stray Light | ≤0.1% T @ 360 nm |
| Display | 128 × 64 Dot-Matrix LCD |
| Data Output | USB Port (U-disk export), RS-232 Serial Print Interface |
| Software | AOE Basic Spectroscopy Suite (Certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE, CMC (China Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1300 |
| Power Supply | Rechargeable Li-ion battery (16–24 V), AC adapter & USB power input supported |
| Operating Time | 3–4 h (standard 10,000 mAh battery) |
| Wavelength Range | 325–1020 nm |
| Light Source | Tungsten-halogen lamp |
| Stray Light | ≤0.1% T at 340 nm (NaNO₂) |
| Photometric Stability | ±0.002 A |
| Display | 128 × 64 dot-matrix LCD |
| Measurement Modes | Absorbance (A), Transmittance (T), Concentration (C), Factor (F) |
| Sample Holder | Single-cuvette compartment (10 mm pathlength) |
| Interface | USB 1.0 (PC connectivity & software control) |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | V-1600 |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±0.4 nm |
| Spectral Bandwidth | 4.0 nm |
| Stray Light | ≤0.04%T |
| Wavelength Scanning Mode | Automatic |
| Display | 480 × 272 TFT Color LCD (65K colors) |
| Data Storage | 240 calibration curves (240 data points per curve) onboard |
| Interface | Dual USB 2.0 ports (data export & printer connectivity), USB 1.0 for PC communication |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1600PC |
| Optical System | Pseudo-Double-Beam (Ratio-Monitoring) |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±0.4 nm |
| Spectral Bandwidth | 4.0 nm |
| Stray Light | ≤0.04% T @ 360 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | 240 calibration curves (240 data points each) onboard |
| Interface | Dual USB 2.0 ports (data export & printer), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Suite (certified under China Copyright Protection Center, Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V-1800 |
| Price Range | USD 1,400–2,800 (FOB) |
| Optical System | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 220 nm & 360 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | V-1800PC |
| Price Range | USD 1,400–2,800 |
| Optical Design | Pseudo-Double-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Scanning | Motorized Auto-Scanning |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Stray Light | ≤0.04% T @ 360 nm and 600 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | V-1900 |
| Price Range | USD 2,800 – 4,200 (FOB Shanghai) |
| Optical Design | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.4 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Stray Light | ≤0.04% T @ 360 nm and 600 nm |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | Onboard memory for 240 calibration curves (240 data points per curve) |
| Data Export | USB 2.0 × 2 (for printer & storage), USB 1.0 for PC connectivity |
| Software | AOE Basic Spectroscopy Software (certified under China Copyright Protection Center, Registration No. 2021SRXXXXXX) |
| Compliance | ISO 9001:2015, CE, CMC (China Metrology Certification), RoHS Directive 2011/65/EU |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | V-1900PC |
| Optical System | Single-Beam with Dual-Beam Ratio Monitoring |
| Detector Type | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.04% T |
| Wavelength Scanning Mode | Automatic |
| Display | 480 × 272 pixel, 65K-color TFT LCD |
| Data Storage | 240 calibration curves (240 data points per curve) onboard |
| Interface | Dual USB 2.0 ports (data export & printer connection), USB 1.0 for PC communication |
| Software | AOE Basic Spectroscopy Software (certified under PRC Copyright Registration No. [redacted for privacy]) |
| Compliance | ISO 9001, CE, CMC, RoHS |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | V110Pro |
| Price Range | USD 700–1,400 |
| Optical Design | Single-Beam |
| Detector Type | Silicon Photocell |
| Wavelength Range | 325–1100 nm |
| Wavelength Scanning Mode | Motorized Automatic |
| Spectral Bandwidth | 4.0 nm |
| Wavelength Accuracy | ±1.5 nm |
| Stray Light | ≤0.1% T at 220 nm and 360 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Baseline Stability | ±0.001 A/h at 500 nm |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | V120Pro |
| Price Range | USD 700–1,400 (FOB) |
| Optical System | Single-Beam with Holographic Grating (1200 lines/mm) |
| Detector | Silicon Photocell |
| Wavelength Range | 320–1100 nm |
| Wavelength Accuracy | ±1.0 nm |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 4.0 nm |
| Stray Light | ≤0.1%T at 220 nm and 360 nm |
| Baseline Stability | ±0.001 A/h at 500 nm |
| Wavelength Scanning Mode | Motorized Auto-Scanning |
| Display | 7-inch TFT LCD Touchscreen |
| Data Output | USB 2.0, RS-232, Optional PC Software |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Model | X-200 / X200S / X-201 |
| Optical System | Pseudo-Double-Beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | 1.0 nm (X-200), 1.8 nm (X-201), 1.0/2.0/3.0/5.0 nm (X200S) |
| Stray Light | ≤0.01%T @ 220 nm & 360 nm |
| Photometric Accuracy | ±0.2%T |
| Photometric Repeatability | ≤0.08%T |
| Baseline Flatness | ±0.0005 Abs |
| Drift | 0.0004 Abs/h @ 500 nm |
| Noise | ±0.00008 Abs |
| Wavelength Scanning Speed | 31,800 nm/min |
| Data Point Resolution | 0.1–10 nm (selectable) |
| Display | 8-inch backlit capacitive touchscreen LCD |
| Operating System | WinCE 6.6 |
| Sample Holder | Standard automatic 6-cell rotating cuvette changer |
| Interface | USB, Ethernet, RS-232, Printer port |
| Connectivity | Wired LAN & optional Wi-Fi module |
| Firmware Update | USB-based one-click upgrade via instrument serial number |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1200 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1301 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1302 |
| Detection Elements | K, Na, Ca |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Optical System | Interference filter-based monochromator with three dedicated channels (K, Na, Ca) |
| Detector | Silicon photovoltaic cell |
| Calibration Modes | Linear, segmented linear, and quadratic polynomial fitting |
| Stability | ≤ 3% RSD over 15 s |
| Linearity Error | K ≤ 0.005 mmol/L |
| Ignition System | One-touch electronic ignition with flame-ionization safety cutoff and auto-alarm (8 s timeout) |
| Interface | RS232 serial port for PC or printer connectivity |
| Dimensions | 440 × 310 × 500 mm |
| Weight | 12.5 kg |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 250 W |
| Operating Environment | 10–35 °C, RH ≤ 85%, vibration-free, non-corrosive, non-explosive atmosphere |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1401 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Detection Limits | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Aspiration Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1402 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.0004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1500 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Aspiration Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1500 GMP Edition |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limits | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | FP640 |
| Price | USD 1,280 (FOB Shanghai) |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Uptake Rate | < 6 mL/min |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 7-inch Color Touchscreen |
| Ignition System | One-Touch Auto-Ignition with Flame Ionization Safety Cut-off |
| Fuel Compatibility | Liquefied Petroleum Gas (LPG), Propane, or Butane |
| Linear Error | K ≤ 0.005 mmol/L |
| Stability | ≤ 3% max variation within 15 s |
| Operating Environment | 10–35 °C, RH ≤ 85%, Stable Horizontal Surface, No Strong EMI/Vibration, Proper Grounding, 220 V ± 10%, 50 Hz ± 1 Hz, 250 W Max |
| Dimensions | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Standard Configuration | Main Unit, Integrated Air Compressor, Calibration Standards, Capillaries, Filters, User Manual, and Safety Accessories |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FP6400A |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 7-inch Color Touchscreen |
| Ignition System | One-Touch Ignition with Flame Ionization Safety Cut-off |
| Fuel Compatibility | Liquefied Petroleum Gas (LPG), Propane, or Butane |
| Linear Error | K ≤ 0.005 mmol/L |
| Stability | ≤ 3% RSD over 15 s |
| Operating Environment | 10–35 °C, RH ≤ 85%, Stable Horizontal Surface, Grounded 220 V ± 10%, 50 Hz ± 1 Hz, 250 W Max |
| Dimensions | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FP650 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | APL / Applied Photonics Ltd |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gemmology |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Wavelength | 266 nm |
| Pulse Energy | >20 mJ per pulse |
| Repetition Rate | Up to 10 Hz |
| Spectral Range (configurable) | 185–1000 nm |
| Number of Spectrometer Channels | Up to 8 |
| Imaging | Dual high-resolution color cameras (top-view + side-view, orthogonal to laser axis) |
| Sample Chamber | Modular — SC-2L manual chamber standard |
| Gas Purge | External inert gas interface (Ar, N₂, He, air) |
| Software | LIBSoft™ v5.x (2-year free upgrade included) |
| Brand | APL/Applied Photonics Ltd |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 150-10 |
| Instrument Type | Benchtop |
| Integration | Integrated |
| Laser Energy | >20 mJ |
| Laser Wavelength | 1064 nm |
| Repetition Rate | 10 Hz (150 mJ) or 20 Hz (120 mJ) |
| Plasma Light Collection Channels | 6 or 8 |
| Spectrometer Support | Up to 8 independent spectrometers |
| Spectral Range | ~182–1016 nm |
| Sample Chamber Options | Modular, motorized multi-axis stage, open-beam configuration |
| Gas Purge | Compatible with Ar, N₂, He, or air supply |
| Optional Imaging Kit | IMG-HR (2.5 MP color imaging) |
| Software | LIBSoft™ (free updates for 2 years) |
| Host Computer | External laptop or desktop required (specifications available upon request) |
| Brand | APL/Applied Photonics Ltd |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | LIBS Probe 60 |
| Instrument Type | Handheld |
| Integration | Integrated Unit |
| Laser Pulse Energy | 50–60 mJ |
| Operating Depth | 10–30 m underwater |
| Laser Source | Air-Cooled, Flashlamp-Pumped Passive Q-Switched Nd:YAG |
| Repetition Rate | Up to 1 Hz |
| Gas Purge Mechanism | Compressed Air Jet for Optical Path Drying |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MS100 |
| Spectral Range | 380–780 nm |
| Spectral Resolution | 1 nm |
| FWHM | ~12 nm |
| Wavelength Repeatability | ±1 nm |
| PPFD Range | 0.1–3,500 µmol/m²/s |
| Illuminance Range | 5–190,000 lx |
| Illuminance Accuracy | ±5 % (Illuminant A, 2856 K, 20,000 lx) |
| Chromaticity Accuracy | ±0.0025 in CIE 1931 x,y |
| CCT Accuracy | ±2 % |
| CRI Accuracy | ±1.5 % |
| Diffuse Rejection | −25 dB |
| Integration Time | 6–1,000 ms |
| Operating Temperature | 0–35 °C (RH ≤70 %, non-condensing) |
| Storage Temperature | −10–40 °C (RH ≤70 %, non-condensing) |
| Display | 0.96″ 128×64 monochrome OLED |
| Battery | 700 mAh / 3.7 V rechargeable Li-ion |
| Weight (with battery) | 70 g ±5 g |
| Dimensions | 90 × 30 × 32.2 mm |
| Data Storage | microSDHC up to 32 GB (supports ≥120,000 Excel files) |
| Connectivity | Mini-USB 2.0, Bluetooth 3.0/4.0 (iOS & Android compatible) |
| Software | Apogee InSight (Windows, macOS, iOS, Android) |