Spectroscopy Instruments
Filter
Showing 181–210 of 1322 results
| Brand | Apogee |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | PS-100 / PS-200 / PS-300 |
| Price | Upon Request |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SS-120 |
| Spectral Range | 635–1100 nm |
| Spectral Sampling Interval | 1.0 nm |
| Spectral Resolution | 3.0 nm |
| Spectral Accuracy | ±0.5 nm |
| Spectral Repeatability | ±0.2 nm |
| A/D Conversion | 14-bit |
| Signal-to-Noise Ratio | 1500:1 |
| Stray Light | ≤0.25% at 850 nm |
| Noise Level | ≤3 counts |
| Integration Time | 10 ms – 10 s |
| Linearity | <1% or 0.5% |
| Quantum Efficiency | >10% (λ < 1030 nm) |
| Radiometric Repeatability | <1% (λ < 1020 nm) |
| Cosine Response Error | ±5% at 75° zenith angle |
| Field of View | 25° or 150° (downward-facing configuration) |
| Operating Temperature | −20 to +70 °C |
| Relative Humidity | 0–100% RH |
| Power Consumption | 1 W (USB-powered) |
| Current Draw | 190 mA |
| Weight | 300 g |
| Dimensions | 89.3 × 50.8 × 38.1 mm (H × W × L) |
| Communication Interface | USB |
| Software Compatibility | Windows XP and later |
| Irradiance Calibration Uncertainty | ±5% |
| Temperature Coefficient | −0.1 ± 0.1 %/°C |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SU-200-SS / SU-202-SS / SU-205-SS |
| Spectral Range | 300–400 nm |
| Output Types | 0–10 mV (SU-200-SS), 0–2.5 V (SU-202-SS), 0–5 V (SU-205-SS) |
| Calibration Unit | W·m⁻² (irradiance) |
| Measurement Range | 0–100 W·m⁻² |
| Spectral Bandwidth | 300–400 nm |
| Wavelength Accuracy | ±5% |
| Stray Light Rejection | ±1% |
| Operating Temperature | −35 to +85 °C |
| Relative Humidity Range | 0–100% RH |
| Housing IP Rating | IP68 |
| Cable Length | 5 m |
| Sensor Diameter × Height | Φ30.5 × 37 mm |
| Weight | 140 g |
| Long-Term Drift | <2% per year |
| Nonlinearity | <1% |
| Directional Response | ±2% at 45°, ±5% at 75° |
| Temperature Coefficient | 0.1% / °C |
| Calibration Uncertainty | ±10% |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Model Designation | Chirascan |
| Compliance | CE, UKCA |
| Optical Path | Dual-beam, photoelastic modulator (PEM)-based |
| Wavelength Range | 170–900 nm |
| Temperature Control Range | −40 °C to +120 °C (with optional cryostat & Peltier units) |
| Data Acquisition Rate | Up to 500 points/sec |
| Signal-to-Noise Ratio | <0.005 mdeg (at 220 nm, 1 nm bandwidth, 1 s time constant) |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chirascan CPL |
| Instrument Type | Circular Dichroism / Circularly Polarized Luminescence Spectrometer |
| Optical Path Configurations | 90° and 180° fluorescence detection modes |
| Excitation Range | 170–900 nm (deep-UV capable with N₂ purge) |
| Monochromator | F/7 double-prism design |
| Polarization Optics | Dual high-fidelity polarization prisms |
| Data Acquisition | Digital signal processing (DSP) architecture with adaptive integration time control |
| Sample Compatibility | Liquids, powders, films, gels, turbid suspensions, and opaque solids |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Circular Dichroism (CD) and Synchronous Fluorescence Spectrometer |
| Model | Chirascan Plus |
| Detection Technology | Large-Area Avalanche Photodiode (LAAPD) Detector |
| Wavelength Range | 170–900 nm (CD), 200–900 nm (Fluorescence) |
| Sensitivity | Enhanced vs. standard Chirascan (LAAPD-enabled) |
| Automation | Optional unattended high-throughput configuration |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Model | Chirascan Q100 CD |
| Detection Range | 170–1700 nm |
| Optical Design | Dual Rochon Prism Monochromator |
| Detector Options | LAAPD (1200 nm), InGaAs (up to 1700 nm) |
| Automation Level | Fully Integrated, Unattended Operation |
| Compliance | Designed for GLP/GMP-aligned biophysical characterization |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | Stopped-Flow Accessory for Chirascan CD Spectrometer |
| Instrument Type | Circular Dichroism (CD) |
| Dead Time | ≤1.5 ms |
| Cuvette Volume | 20 µL (switchable 2 mm / 10 mm pathlength) |
| Compatibility | Fully integrated with Chirascan series CD spectrometers |
| Detection Modes | Stopped-flow CD, absorption, fluorescence, fluorescence polarization, diode array, quench-flow |
| Optional Modules | Multi-channel rapid mixing system, dual fluorescence detection, time-resolved absorption |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Chirascan V100 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Price Range | USD 170,000 – 390,000 (estimated FOB UK) |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SUPR-DSF |
| Photomultiplier Tube Wavelength Range | 160 nm – 1200 nm |
| Atomizer Temperature Control Range | −50 °C to 150 °C |
| Throughput | 384 samples per thermal ramp (60–80 min) |
| Sample Volume | 10–20 µL per well |
| Sample Concentration Range | 0.05–250 mg/mL |
| Temperature Scan Range | 10 °C to 105 °C |
| Detection Method | Full-spectrum fluorescence acquisition with centroid-based analysis |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Stopped-Flow CD/Fluorescence/Absorption Spectrometer |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Software | Pro-Data acquisition and kinetic analysis suite (FDA 21 CFR Part 11 compliant audit trail optional) |
| Detector Options | Photodiode array, dual photomultiplier tubes, fluorescence polarization module, CD-compatible stopped-flow cell |
| Mixing Systems | Single-, double-, or triple-syringe configurations |
| Temperature Control | ±0.1 °C over 5–40 °C range |
| Data Acquisition Rate | Up to 100 kHz (depending on detector configuration) |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Circular Dichroism (CD) Stopped-Flow Spectrometer |
| Detection Principle | Far-UV to Near-UV CD spectroscopy (170–450 nm) |
| Flow Precision | ≤1% RSD per injection |
| Dead Time | <1.0 ms (with optimized cell and drive system) |
| Temperature Control Range | 4–80 °C (±0.1 °C stability) |
| Data Acquisition Rate | Up to 20,000 points/sec (CD signal at single wavelength) |
| Compliance | ASTM E2915, ISO/IEC 17025–compliant operation framework, supports 21 CFR Part 11–ready audit trail via KineticStudio software |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Circular Dichroism (CD) Stopped-Flow Spectrometer |
| Application Domain | Transient Kinetics, Pre-Steady-State Reaction Analysis |
| Compliance Context | ASTM E259, ISO 17025 (for kinetic method validation), GLP/GMP-ready data audit trail support |
| Brand | Applied Photophysics |
|---|---|
| Origin | United Kingdom |
| Model | SX20 |
| Instrument Type | Circular Dichroism (CD) Stopped-Flow Spectrometer |
| Detection Options | Diode Array, Dual Fluorescence, Fluorescence Polarization, Quench-Flow, Multi-Channel Sequential Mixing, CD-Stopped-Flow Module |
| Brand | Applied Spectra |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | J200 |
| Price Range | USD 140,000 – 700,000 |
| Instrument Type | Benchtop |
| Integration | Fully Integrated |
| Laser Energy | 25–100 mJ |
| Wavelength Options | 1064 nm, 266 nm, 213 nm, 343 nm (femtosecond), 1030 nm (femtosecond) |
| Spectrometer Options | EN4, EN6, SHP, IHP, RHP (dual-spectrometer configurations supported) |
| Sample Cell Options | Standard Flex Chamber, Cryo Cell, FlexSeal LA, FlexSeal Chamber, THP Cell – Standard Washout, THP Cell – Fast Washout |
| Brand | Aragon Photonics |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BOSA-500 |
| Optical Band Coverage | O, S, C, and L bands |
| Optical Resolution | 10 MHz @ 1310 nm or 1550 nm (0.08 pm) |
| Wavelength Accuracy | ±0.5 pm @ C/C+L/S+C+L bands |
| Spurious-Free Dynamic Range (SFDR) | >80 dB |
| Core Technology | Stimulated Brillouin Scattering (SBS)-based tunable optical filtering |
| Integrated Tunable Laser Source (TLS) | Yes |
| Polarization-Resolved Spectral Measurement | Supported |
| Phase-Spectral Characterization Capability | Yes (e.g., chirp, eye diagram, constellation analysis) |
| Brand | ARC |
|---|---|
| Origin | Switzerland |
| Model | FT-NIR Rocket |
| Instrument Type | Portable |
| Spectral Range | 900–2600 nm (11000–3800 cm⁻¹) |
| Resolution | 4 cm⁻¹ (≤0.8 nm @ 1100 nm, ≤2 nm @ 1700 nm, ≤5 nm @ 2600 nm) |
| Wavenumber Accuracy | <1 cm⁻¹ @ 4000 cm⁻¹ (25±5°C) |
| Signal-to-Noise Ratio | >10,000:1 (RMS, full spectrum, single scan) |
| Dynamic Range | >3000:1 |
| Scan Speed | 1 spectrum/sec (averaging mode) |
| A/D Conversion | 24-bit |
| Detector | InGaAs photodiode array |
| Reference Laser | Integrated solid-state 850 nm laser |
| Optical Interface | SMA905, fiber input ≥1 mm core, NA = 0.2 |
| Power Supply | 5 V DC via USB 2.0 |
| Operating Temperature | 10–30 °C |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 850 g |
| Compliance | CE, RoHS, USB-IF certified |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Instrument Type | Laboratory FT-IR |
| Spectral Range | 5000–830 cm⁻¹ |
| Resolution | 0.5 cm⁻¹ (standard 4 cm⁻¹, optional down to 0.5 cm⁻¹) |
| Signal-to-Noise Ratio | > 1:40,000 (at 8 cm⁻¹, 60 s acquisition) |
| Detector | Peltier-cooled MCT (4-stage TE), ZnSe beamsplitter |
| Interface | USB 2.0 |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 1.8 kg |
| Operating Temperature | 10–40 °C |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-IR Rocket |
| Detector | Thermoelectrically Cooled HgCdTe (MCT) |
| Interferometer Type | Permanently Aligned Dual Corner-Cube Design |
| Reference Laser | Solid-State Stabilized Laser (PPM-level wavelength stability) |
| Spectral Range | Mid-Infrared (Typical 2–12 µm, configuration-dependent) |
| Optical Interface | Fiber-Coupled or Free-Space Input |
| Resolution | Up to 0.5 cm⁻¹ (configurable) |
| Scan Rate | Up to 10 scans/sec (typical) |
| Weight | < 1.2 kg |
| Dimensions | 120 × 85 × 65 mm |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-IR Rocket |
| Detector | Thermoelectrically Cooled MCT (2-stage or 4-stage) |
| Spectral Range | Mid-IR (typically 2.5–12 µm / 4000–833 cm⁻¹, configuration-dependent) |
| Resolution | 4 cm⁻¹ or 8 cm⁻¹ |
| Coupling Options | Fiber-optic (SMA-905 or FC/PC) and Free-space |
| Light Source | Integrated Broadband IR Emitter |
| Compliance | CE-marked, RoHS-compliant |
| Software Interface | USB 2.0, SDK for LabVIEW, Python, MATLAB |
| Brand | ARCoptix |
|---|---|
| Origin | Switzerland |
| Model | FT-NIR 0.9–2.6 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Spectral Range | 900–2600 nm (3800–11,000 cm⁻¹) |
| Resolution | 4 cm⁻¹ |
| SNR | >200,000:1 (at 4 cm⁻¹, 60 s acquisition) |
| Wavelength Stability | <10 ppm long-term repeatability |
| Baseline Intensity Drift | <2% over 10 h (1100–2500 nm) |
| Detector | Extended-range InGaAs PIN photodiode (thermoelectrically cooled option available) |
| Data Acquisition Rate | 1 spectrum/s (continuous mode) |
| Interface | USB 2.0 (Ethernet optional) |
| A/D | 24-bit |
| Power | 7.5–12 V DC, 1–6 W |
| Operating Temperature | 5–40 °C |
| Dimensions | 180 × 160 × 80 mm |
| Weight | 1.7 kg |
| Brand | Arcoptix |
|---|---|
| Origin | Switzerland |
| Model | FTNIR-L1 |
| Instrument Type | Portable |
| Spectral Range | 11000–3850 cm⁻¹ (0.9–2.6 µm) |
| Resolution | 4 or 8 cm⁻¹ |
| Wavenumber Accuracy | < 2% (1100–2500 nm) over 10 hours |
| Detector | Single-element TE-cooled InGaAs photodiode |
| Input | Fiber-coupled |
| Brand | ARC |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ARCoptix |
| Pricing | Upon Request |
| Spectral Range | 400–1100 nm |
| Spectral Resolution | <5 nm |
| Wavelength Accuracy | <0.5 nm |
| Wavelength Temperature Drift | <0.03 nm/°C |
| Stray Light Suppression | –27 dB (broadband), –35 dB (narrowband) |
| Radiometric Accuracy | <5% |
| Dynamic Range | 5000:1 |
| Integration Time | 0.1–2000 ms |
| Wavelength Repeatability | <0.2 nm |
| Field of View (Relative Radiometry) | 10° |
| Field of View (Absolute Radiometry) | 180° |
| Compliance | IEC 60904-9 (Ed. 2), JIS C 8912, ASTM E927, IEC 60904-3 AM1.5 G spectral classes (50 nm bins) |
| Programmable Trigger Delay | 0–2000 ms (0.1 ms resolution) |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Model | FORO-L-3/5-F10 |
| Spectral Range | 3–5 µm |
| Lens Material | ZnSe |
| Lens Type | Plano-Convex |
| Focal Length | 10 mm |
| Numerical Aperture | 0.35 |
| Outer Diameter | 25 mm |
| Thread | M24×1 |
| Housing | Anodized Aluminum (Black) |
| AR Coating | Optimized for 3–5 µm |
| Compatible Connectors | SMA, FC/PC |
| Weight | ~45 g |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Model | CIR Fiber 1.5–6 µm |
| Spectral Range | 0.18–1.2 µm (UV-VIS) |
| Detector Type | CCD |
| Resolution | 30 |
| Sensitivity | 400 |
| Signal-to-Noise Ratio | 1001 |
| Core Diameter Options | 200–1500 µm |
| Numerical Aperture | 0.22 ± 0.02 (25° full acceptance angle) |
| Operating Temperature | −40 °C to +600 °C (copper-coated variant) |
| Connector Types | HP-SMA, D-80 |
| Cable Lengths | 1.5 m, 3.0 m (custom lengths from 5 cm to 50 m) |
| Cladding Material | Fluorine-doped fused silica |
| Core Material | High-OH⁻ or Low-OH⁻ fused silica |
| Jacketing Options | Nylon, Tefzel, acrylic, aluminum, copper |
| Protective Sheathing | PVC-coated stainless steel coil, silicone-coated stainless steel bend protection |
| Brand | ART Photonics |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PIR Fiber |
| Spectral Range | 3–17 µm |
| Brand | Artemis |
|---|---|
| Model | MARS-IRIS |
| Spectral Range | 400–1700 nm |
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Pricing | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | ArtScanner |
| Pricing | Available Upon Request |
| Brand | ARUN TECHNOLOGY LTD. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | High-Resolution CCD Array |
| Spectral Range | 130–700 nm |
| Optical Design | Paschen–Runge Mount with Dual Optical Chambers |
| Cooling | Thermostatically Controlled Enclosure (±0.1 °C) |
| Purge Medium | Argon |
| Compliance | ISO/IEC 17025-ready architecture, GLP/GMP-supporting data integrity features |
| Brand | Arun Technology Ltd. |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | Scientific-grade CMOS Sensor with Active Cooling |
| Wavelength Range | 130–700 nm |
| Element Analysis Time | ≤10 s per measurement |
| Detection Limit | ≤1 ppm for key metallic elements |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, supports GLP/GMP audit trails and ASTM E415, E1086, E1479 methodologies |