| Key | Brand: SPIP |
|---|---|
| Origin | USA |
| Version | 6.0.14 |
| Licensing Model | Perpetual License with Maintenance |
| Supported Microscopy Modalities | SPM/AFM, SEM, TEM, Optical Microscopy, Confocal Microscopy, Interferometry, White-Light Interferometry (WLI), Focus Variation, 3D Profilometry |
| File Format Compatibility | Standard binary and ASCII formats including Gwyddion (.gwy), Nanoscope (.nsi/.nd2), WSxM (.wsxm), Veeco (.spm), Digital Surf (.sur/.sdf), ISO 5436-2, and vendor-neutral TIFF/RAW stacks |
| Deployment | Windows 10/11 (64-bit) |
| Compliance | Supports GLP/GMP-aligned audit trails (via optional Audit Trail Module), ISO 25178-2 surface texture parameter calculation, ASTM E2923-23 for AFM measurement uncertainty reporting |
| Brand | Image Metrology |
|---|---|
| Model | SPIP 6.0.13 |
| Origin | USA |
| Software Type | Modular SPM/SEM/Interferometry Image Processing Platform |
| Supported Modalities | SPM, SEM, TEM, White-Light Interferometry, Confocal Microscopy, Optical Profilometry, 3D Topography |
| Core Modules | Base Analysis Module + 13 Optional Add-on Modules |
| Compliance | ASTM E2927, ISO 25178-2, ISO/IEC 17025 (data integrity workflows), FDA 21 CFR Part 11-ready audit trail (via optional GLP/GMP module) |
| Licensing | Perpetual node-locked or floating license |
| System Requirements | Windows 10/11 64-bit, ≥16 GB RAM, ≥50 GB SSD storage, OpenGL 4.5-compatible GPU |
| Brand | Starwood |
|---|---|
| Model | SDW-18CS |
| Type | Research-Grade Fully Automated Optical Contact Angle Analyzer |
| Construction Material | Aerospace-Grade Aluminum Alloy |
| Power Supply | 220 V, 50–60 Hz |
| Power Consumption | 10 W |
| Dimensions (W × L × H) | 655 × 180 × 520 mm |
| Weight | ~16 kg |
| Sample Stage Travel (X/Y/Z) | 30/50/30 mm (manual, 0.1 mm resolution) |
| Leveling | Full-system + camera-level XY precision leveling (included professional-grade XY level) |
| Sample Platform Size | 130 × 150 mm (customizable) |
| Max Sample Size | 200 (W) × ∞ (L) × 30 (H) mm |
| Dispensing System Y/Z Travel | 40/35 mm (0.1 mm resolution) |
| Dropping Stroke | 60 mm (0.01 mm resolution) |
| Droplet Volume Precision | 0.01 µL |
| Syringe Capacity | 500 µL (auto liquid-level detection) |
| Standard Needles | 0.5 mm stainless steel (20 pcs), 0.25 mm superhydrophobic needle (20 pcs) |
| Camera | Japan Sony industrial-grade CMOS (Onsemi global shutter), 1/1.8″ progressive scan, 1280 × 1024 resolution |
| Lens Magnification | 0.7×–4.5×, focus adjustment ±2.5 mm |
| Max Frame Rate | 80 fps |
| Light Source | US-sourced industrial white cold LED (400–760 nm), quartz diffuser for uniform illumination, 50,000 h lifetime, PWM + software brightness control |
| Contact Angle Methods | Sessile drop, pendant drop, captive bubble, tilting plate (dynamic) |
| Static CA Fitting Algorithms | Circle, Oblique Circle, Ellipse, Oblique Ellipse, B-Snake, concave/convex surface fitting |
| Dynamic CA Analysis | Advancing, receding, hysteresis angles (batch image & video-based analysis) |
| Baseline Detection | Auto/manual |
| Angular Range | 0° < θ < 180° |
| Angular Accuracy | ±0.1° |
| Angular Resolution | 0.001° |
| Surface Energy Models | Fowkes, OWRK, Zisman, EOS, Acid-Base Theory, Wu Harmonic Mean, Extended Fowkes (37 preloaded liquids |
| Surface Tension Range | 0.1–2000 mN/m |
| Surface Tension Accuracy | ±0.01 mN/m |
| Work of Adhesion / Spreading Coefficient / Adhesion Tension | Auto-calculated, resolution 0.001 mN/m |
| Software | CA V2.0 (static/dynamic CA + surface energy + interfacial tension modules) |
| OS Requirement | Windows 10 (64-bit) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Super-Pig |
| Pricing | Upon Request |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DVS Adventure |
| Temperature Range | 5–85 °C |
| Relative Humidity Range | 0–98% RH |
| Sample Mass Capacity | 1–5000 mg |
| In-situ Heating/Drying Capability | up to 300 °C |
| Humidity Generation Method | Dual-gas mixing (dry carrier gas + saturated vapor) with digital mass flow control |
| Compatibility | Raman spectroscopy (via optical fiber), color video microscopy, NIR spectroscopy |
| Modularity | Upgradable to organic vapor sorption |
| Construction | Anti-static stainless steel |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | T/A |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Spec&Scan 2000 |
| Pricing | Upon Request |
| Brand | Tailin |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HTY-202 |
| Pressure Resolution | 0.005 MPa |
| Maximum Operating Pressure | 0.6 MPa |
| Power Source | Compressed Air or Nitrogen |
| Weight | 5 kg |
| Measurement Principle | Bubble Point Method (Based on H. Bechhold’s Theory) |
| Brand | Teclis Scientific (France) |
|---|---|
| Origin | France |
| Model | FOAMSCAN |
| Gas Flow Range | 20–500 mL/min (mass flow controlled) |
| Stirring Speed | 500–6000 rpm (software-controlled) |
| Temperature Measurement | Pt100 sensor (ambient or optional water bath coupling) |
| Dual-Camera Imaging System | Primary foam height + secondary bubble structure |
| Modular Foaming Methods | Gas injection (via sintered glass frit), Mechanical stirring, External foam introduction |
| Automated Cleaning System | Dual-fluid (water + optional cleaning agent), integrated waste pump |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | FOAMSCAN HTMP |
| Max Operating Temperature | 120 °C |
| Max Operating Pressure | 8 bar |
| Gas Flow Range | 100–5000 mL/min |
| Imaging | USB 2.0 CCD camera (744 × 480 px, 76 fps), dual focal lengths (2.9 mm / 8.2 mm) |
| Sample Cell | triple-walled cylindrical glass tube with integrated Pt100 temperature sensor and conductivity electrodes |
| Cleaning | automated rinse system |
| Compliance | compatible with GLP/GMP workflows |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER HTHP 700 |
| Measurement Range | 0.01–1000 mN/m |
| Resolution | ±0.01 mN/m |
| Accuracy | 0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Pendant Drop or Rising Drop Shape Analysis |
| Maximum Pressure | 700 bar |
| Optical Cell Material | Sapphire Windows with Inconel 625 Housing |
| Imaging System | USB2 CCD Camera (640×480, 60 fps), Telecentric Lens (f = 55 mm), Zoom Ratio 0.5–0.05, Working Distance 98–191 mm |
| Brand | Teclis Scientific (France) |
|---|---|
| Origin | France |
| Model | TRACKER |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | 0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Method | Pendant Drop / Sessile Drop / Rising Bubble / Captive Bubble |
| Camera | Monochrome CCD, 640×480 px, up to 60 fps (optional high-speed: 600 fps) |
| Optical System | Telecentric lens + dual-intensity LED backlight |
| Sample Cell | Jacketed thermostatted cell with integrated magnetic stirrer |
| Temperature Control | Circulating bath (up to 90 °C), embedded Pt100 sensor (±0.2 °C) |
| Software | Young–Laplace fitting, dynamic interfacial rheology (dilatational modulus E', E''), contact angle hysteresis (advancing/receding), CMC determination, batch analysis, audit-trail-ready data logging |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER H |
| Measurement Range | 0.1–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.5 °C |
| Measurement Method | Pendant Drop Method |
| Max Pressure | 200 bar |
| Max Temperature | 200 °C |
| Compatible Gases | Supercritical CO₂, N₂, Ar, air, CO₂ |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° |
| Dynamic Contact Angle Accuracy | ±0.1° |
| Brand | Teclis Scientific |
|---|---|
| Origin | France |
| Model | TRACKER HTHP |
| Measurement Range | 0–1000 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Temperature Range | 0–200 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Pendant Drop Method |
| Maximum Pressure | 700 bar |
| Optical System | Monochrome CCD Camera (640 × 480 px), Telecentric Lens, Up to 60 fps (optional high-speed camera: 600 fps) |
| Pressure Certification | CETIM-certified pressure chamber |
| Origin | Sweden |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Theta-3D |
| Instrument Class | Dynamic Contact Angle Analyzer |
| Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0–180° |
| Angular Resolution | 0.1° |
| Sample Stage Dimensions (L × W × H) | Unlimited × 180 mm × 22 mm |
| Image Resolution | 1280 × 960 pixels |
| Surface & Interfacial Tension Range | 0–1000 mN/m |
| Brand | TIAST |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TI-DZ Series |
| Pricing | Available Upon Request |
| Measurement Current Options | 3 A, 5 A, 15 A (user-configurable) |
| Channel Capacity | Multi-channel, Group-assignable |
| Data Interface | RS232/RS485/Ethernet (protocol provided upon request) |
| Software | Proprietary Windows-based Control & Analysis Suite |
| Environmental Integration | Compatible with climate chambers (temperature/humidity logging, time-scheduled testing, alarm monitoring) |
| Compliance Support | GLP-compliant audit trail (optional), ISO/IEC 17025 traceability-ready |
| Brand | Tohei Industry Co., Ltd. |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MODEL HM410 |
| Price | Upon Request |
| Fiber Diameter Range | Φ5 µm and above |
| Matrix Compatibility | Thermoplastic resins, thermosetting resins, elastomers |
| Test Temperature Range | Ambient to 400 °C |
| Test Atmosphere | Air or N₂ |
| Imaging System | Microscope-integrated CCD camera |
| Tensile Load Capacity | Up to 500 gf (≈4.9 N) |
| Crosshead Speed | 0.06 mm/min adjustable |
| Dimensions (W×D×H) | 770 × 600 × 750 mm |
| Power Supply | AC 100 V, 50/60 Hz, 500 VA |
| Brand | TOPAS |
|---|---|
| Origin | Germany |
| Model | PSM-165 |
| Measurement Principle | Capillary Flow Porometry (CFP) |
| Pore Size Range | 0.25–130 µm |
| Max Test Pressure | 6 bar |
| Operating Fluid | TOPOR® wetting liquid (custom-formulated fluorinated inert fluid) |
| Power Supply | 110–230 V AC |
| Dimensions (W×H×D) | 480 × 390 × 310 mm |
| Weight | 12 kg |
| Compliance | ASTM E1294-89, ASTM F316-03 |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TQC |
| Pricing | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-assembled) |
| Model | TX-500C |
| Price Range | USD 14,000 – 28,500 |
| Surface/Interfacial Tension Range | 1×10⁻⁶ – 100 mN/m |
| Measurement Resolution | 0.001 mm |
| Measurement Accuracy | ±0.1% of reading |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Rotating Drop |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FORM DDI |
| Price Range | USD 68,000 – 136,000 |
| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-1510 |
| Measurement Range | 2–200 mN/m |
| Resolution | 0.01 mN/m |
| Accuracy | ±0.1 mN/m |
| Temperature Display Range | 0–40 °C |
| Temperature Display Precision | ±0.1 °C |
| Measurement Method | Du Noüy Ring Method |
| Repeatability | ≤0.2% RSD |
| Power Consumption | ≤20 W |
| Operating Environment | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 270 × 185 × 360 mm |
| Weight | 7.5 kg |
| Compliance Standard | GB/T 6541 (Petroleum Products — Determination of Interfacial Tension Between Oil and Water — Du Noüy Ring Method) |
| Brand | YDWO |
|---|---|
| Origin | Shanghai, China |
| Model | WBL Series |
| Measurement Principle | Static Volumetric Nitrogen Physisorption at 77 K |
| Adsorption Gas | N₂ (default), He |
| P/P₀ Range | 1×10⁻⁶–0.998 |
| Surface Area Range | ≥0.0005 m²/g |
| Pore Size Analysis Range | 3.5–5000 Å |
| Pressure Sensor | Imported absolute pressure transducer, 0–133 kPa, ±0.12% FS |
| Temperature Sensors | PT-100, ±0.1 °C |
| Vacuum System | Imported dual-stage rotary vane pump, ultimate vacuum ≤1.0×10⁻⁴ Torr |
| Dewar Capacity | 2 L metal cryostat, >80 h hold time |
| Sample Stations | 1–3 independent analysis ports (model-dependent) |
| Data Output | BET, Langmuir, BJH, t-plot, D-A, H-K, NLDFT/GCMC pore size distributions, isotherms, total pore volume/surface area |
| Brand | YDWO (Yidian Woguang) |
|---|---|
| Model | WBL Series |
| Measurement Principle | Static Volumetric Nitrogen Physisorption at 77 K |
| Adsorption Gas | High-Purity N₂ (99.999%), optional He |
| P/P₀ Range | 1×10⁻⁶ to 0.998 |
| Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Size Analysis Range | 0.35–500 nm (3.5–5000 Å) |
| Pressure Sensors | 3–6 × high-accuracy absolute transducers (0–133 kPa, ±0.12% FS) |
| Temperature Sensor | PT-100 (±0.1 °C) |
| Cryostat | 2 L metal Dewar, >80 h hold time |
| Ultimate Vacuum | ≤1.0×10⁻⁴ Torr |
| Vacuum Pump | Imported dual-stage rotary vane pump |
| Sample Capacity | 1–3 stations (model-dependent) |
| Compliance | ISO 9277, ISO 15901, GB/T 119587 |
| Software | Integrated analysis suite for BET, Langmuir, BJH, t-plot, D-A, H-K, NLDFT, GCMC, and true density calculation |
| Output | Printable reports & Excel export (isotherms, surface area, pore volume/area distribution, cumulative metrics) |
| Measurement Range | ±2 kV |
|---|---|
| Test Distance | 5 mm – 25 m |
| Sensing Area Diameter | 25–175 mm |
| Accuracy | ±5% of full scale |
| Resolution | 1 V |
| Operating Temp. | 15–35 °C, RH ≤85% non-condensing |
| Drift | <600 ppm/hour (time), <600 ppm/°C (temp.) |
| Response Time | <25 ms |
| Display | 3.5-digit LCD |
| Dimensions | 31 × 59 × 173 mm |
| Weight | 200 g |
| Power | 9 V battery (8 h continuous operation) |
| Analog Output | Yes |
| Hold Function | Yes |
| Sensor Thickness | Ultra-thin probe design |
| Key | Brand: Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-WD100 |
| Contact Angle Range | 0–180° |
| Measurement Accuracy | ±0.1° |
| Measurement Methods | Sessile Drop, Insertion, Captive Bubble |
| Analysis Algorithms | Automatic Circle Fitting, Ellipse Fitting, Curved Surface Fitting, Height-Width Method, Tangent Method, Dynamic Sequence Analysis |
| Surface Energy Models | Fowkes, OWRK, Zisman, EOS |
| Stage Travel (X/Y/Z) | 100/100/50 mm (sample stage), 150 mm (fixed plate), 80 mm (microscope, ±3 mm fine adjustment) |
| Sample Max Size | 100 mm (W) × 80 mm (D) |
| Microscope | 2× Fixed-Magnification Optical System |
| Imaging | High-Resolution CMOS Camera with Video Capture, Frame-by-Frame Export, Real-Time Playback |
| Lighting | Adjustable Cold LED Backlight |
| Compliance Standards | GB/T 24368–2009, SY/T 5153–2007, ASTM D724–99(2003), ASTM D5946–2004, ISO 15989 |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-600A |
| Measurement Range | 2–500 mN/m |
| Accuracy | ±0.4 mN/m |
| Sensitivity | 0.1 mN/m |
| Detection Method | Du Noüy Ring Method |
| Power Supply | AC 220 V ±5%, 50 Hz ±2.5% |
| Power Consumption | 50 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Temperature Control | PID Auto-Tuning |
| Sample Capacity | 3 positions |
| Display | High-Resolution Color Touchscreen |
| Data Output | Auto-printing & Real-time Dynamic Tension Curve Visualization |
| Calibration | Single-Point Calibration Protocol |
| Brand | ZEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZD-180D Steam Condensation & Fog Removal Unit |
| Instrument Type | Static Vapor Adsorption System |
| Temperature Range | 5–55 °C |
| Humidity Range | 10–99 % RH |
| Humidity Accuracy | ±5 % RH |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Zhengye Smart Warehouse |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Model | ZK2130 |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Accuracy | ±1% at 50 Ω |
| Measurement Length | 0.05–2 m |
| Horizontal Resolution | 0.2 mm |
| Vertical Resolution | 0.05 Ω |
| Bandwidth | 3 GHz |
| Test Modes | Single-Ended & Differential |
| Channel Configurations | 2-channel or 4-channel |
| Compliance | IPC-TM-650, IPC-2141 |
| Data Analysis | Integrated SPC module for statistical process control |
| Operating System | Windows-based GUI |
| Reporting | Automated report generation with waveform export, CSV data logging, and printer support |
| Brand | ZHONGHUAN FURNACE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TA-16B01, TA-Z16B01 |
| Instrument Category | High-Temperature Vacuum Contact Angle Measurement System |
| Instrument Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Accuracy | ±1° |