Surface & Interface Property Testing
Filter
Showing 691–720 of 723 results
| Brand | YDWO (Yidian Woguang) |
|---|---|
| Model | WBL Series |
| Measurement Principle | Static Volumetric Nitrogen Physisorption at 77 K |
| Adsorption Gas | High-Purity N₂ (99.999%), optional He |
| P/P₀ Range | 1×10⁻⁶ to 0.998 |
| Surface Area Range | ≥0.0005 m²/g (no upper limit) |
| Pore Size Analysis Range | 0.35–500 nm (3.5–5000 Å) |
| Pressure Sensors | 3–6 × high-accuracy absolute transducers (0–133 kPa, ±0.12% FS) |
| Temperature Sensor | PT-100 (±0.1 °C) |
| Cryostat | 2 L metal Dewar, >80 h hold time |
| Ultimate Vacuum | ≤1.0×10⁻⁴ Torr |
| Vacuum Pump | Imported dual-stage rotary vane pump |
| Sample Capacity | 1–3 stations (model-dependent) |
| Compliance | ISO 9277, ISO 15901, GB/T 119587 |
| Software | Integrated analysis suite for BET, Langmuir, BJH, t-plot, D-A, H-K, NLDFT, GCMC, and true density calculation |
| Output | Printable reports & Excel export (isotherms, surface area, pore volume/area distribution, cumulative metrics) |
| Measurement Range | ±2 kV |
|---|---|
| Test Distance | 5 mm – 25 m |
| Sensing Area Diameter | 25–175 mm |
| Accuracy | ±5% of full scale |
| Resolution | 1 V |
| Operating Temp. | 15–35 °C, RH ≤85% non-condensing |
| Drift | <600 ppm/hour (time), <600 ppm/°C (temp.) |
| Response Time | <25 ms |
| Display | 3.5-digit LCD |
| Dimensions | 31 × 59 × 173 mm |
| Weight | 200 g |
| Power | 9 V battery (8 h continuous operation) |
| Analog Output | Yes |
| Hold Function | Yes |
| Sensor Thickness | Ultra-thin probe design |
| Key | Brand: Yuelian |
|---|---|
| Origin | Guangdong, China |
| Model | YL-WD100 |
| Contact Angle Range | 0–180° |
| Measurement Accuracy | ±0.1° |
| Measurement Methods | Sessile Drop, Insertion, Captive Bubble |
| Analysis Algorithms | Automatic Circle Fitting, Ellipse Fitting, Curved Surface Fitting, Height-Width Method, Tangent Method, Dynamic Sequence Analysis |
| Surface Energy Models | Fowkes, OWRK, Zisman, EOS |
| Stage Travel (X/Y/Z) | 100/100/50 mm (sample stage), 150 mm (fixed plate), 80 mm (microscope, ±3 mm fine adjustment) |
| Sample Max Size | 100 mm (W) × 80 mm (D) |
| Microscope | 2× Fixed-Magnification Optical System |
| Imaging | High-Resolution CMOS Camera with Video Capture, Frame-by-Frame Export, Real-Time Playback |
| Lighting | Adjustable Cold LED Backlight |
| Compliance Standards | GB/T 24368–2009, SY/T 5153–2007, ASTM D724–99(2003), ASTM D5946–2004, ISO 15989 |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-600A |
| Measurement Range | 2–500 mN/m |
| Accuracy | ±0.4 mN/m |
| Sensitivity | 0.1 mN/m |
| Detection Method | Du Noüy Ring Method |
| Power Supply | AC 220 V ±5%, 50 Hz ±2.5% |
| Power Consumption | 50 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Temperature Control | PID Auto-Tuning |
| Sample Capacity | 3 positions |
| Display | High-Resolution Color Touchscreen |
| Data Output | Auto-printing & Real-time Dynamic Tension Curve Visualization |
| Calibration | Single-Point Calibration Protocol |
| Brand | ZEDO |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZD-180D Steam Condensation & Fog Removal Unit |
| Instrument Type | Static Vapor Adsorption System |
| Temperature Range | 5–55 °C |
| Humidity Range | 10–99 % RH |
| Humidity Accuracy | ±5 % RH |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Zhengye Smart Warehouse |
| Pricing | Available Upon Request |
| Brand | Zhengye |
|---|---|
| Model | ZK2130 |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Impedance Range | 20–150 Ω |
| Accuracy | ±1% at 50 Ω |
| Measurement Length | 0.05–2 m |
| Horizontal Resolution | 0.2 mm |
| Vertical Resolution | 0.05 Ω |
| Bandwidth | 3 GHz |
| Test Modes | Single-Ended & Differential |
| Channel Configurations | 2-channel or 4-channel |
| Compliance | IPC-TM-650, IPC-2141 |
| Data Analysis | Integrated SPC module for statistical process control |
| Operating System | Windows-based GUI |
| Reporting | Automated report generation with waveform export, CSV data logging, and printer support |
| Brand | ZHONGHUAN FURNACE |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | TA-16B01, TA-Z16B01 |
| Instrument Category | High-Temperature Vacuum Contact Angle Measurement System |
| Instrument Form Factor | Benchtop Laboratory System |
| Contact Angle Measurement Accuracy | ±1° |
| Brand | Zhonghuan Furnace |
|---|---|
| Model | TA-Z16B01 |
| Type | Benchtop High-Temperature Vacuum Contact Angle Measurement System |
| Max Operating Temperature | 1600 °C |
| Vacuum Level | ≤1×10⁻³ Pa |
| Atmosphere Control | Oxygen concentration <10⁻² ppm (in controlled inert/vacuum environment) |
| Imaging Speed | ≥30 fps continuous acquisition |
| Contact Angle Measurement Accuracy | ±1° |
| Software | Automated real-time calculation of θ, d, h, v during thermal cycles |
| Compliance | Designed for GLP-compliant lab environments with audit-ready data logging |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | ZK2130 |
| Measurement Range | 20–150 Ω |
| Measurement Length | 0.05–2 m |
| Bandwidth | 3 GHz |
| Accuracy | ±1% at 50 Ω |
| Test Speed | ≤1 s per point |
| Compliance | Designed for IPC-TM-650 2.5.1 and IEC 61189-2 compliant impedance verification |
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | ZK3185 |
| Price | Upon Request |
| Impedance Measurement Range | 20–200 Ω |
| Measurement Length | 0.02–2 m |
| Bandwidth | 0.1–8.5 GHz |
| TDR Accuracy | ±1% @ 50 Ω |
| Measurement Speed | ≤1 s per point |
| S-Parameter Capability | Yes |
| Dynamic Range | >100 dB |
| Calibration | Full user-accessible multi-point calibration |
| Brand | ZKWN |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | GEST-126 |
| Measurement Principle | Four-Probe DC Resistivity Method with Controlled Compaction |
| Compliance Standards | YS/T 587.6–2006, GB/T 24525–2009, GB/T 24521–2009, GB/T 3782–2016 |
| Resistivity Range | 10⁻⁶ – 10⁵ Ω·cm |
| Resolution | 10⁻⁸ Ω·cm |
| Voltage Ranges | 2 mV / 20 mV / 200 mV / 2 V |
| Current Output | 10 μA – 10 A (8 ranges) |
| Electrode Material | High-Purity Copper |
| Inter-Electrode Spacing | 10 mm |
| Powder Compaction Cylinder ID | 16 mm (optional 30 mm) |
| Stroke | 50 mm |
| Loading Capacity | 10 kN |
| Loading Control | Stepper-Motor-Driven Automatic Constant-Load Application |
| Force & Pressure Display | Real-Time Digital Readout |
| Sample Height Measurement | Integrated Linear Encoder |
| Data Output | Volume Resistivity (Ω·cm), Resistance (Ω), Applied Pressure (MPa), Compaction Time (s) |
| Interface | 7-inch Capacitive Touchscreen HMI |
| Data Export | USB Storage |
| Thermal Drift Stability | <0.05% per hour |
| Measurement Repeatability | ±0.3% at fixed density and temperature |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JF99M |
| Measurement Method | Washburn Capillary Rise Method |
| Pressure Range | 0–330 mbar |
| Pressure Resolution | 0.16 mbar |
| Operating Temperature | Ambient |
| Quartz Tube Dimensions | OD 10 mm, ID 8 mm or 6 mm |
| Power Supply | 220 V AC, 20 W |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK15A |
| Price Range | USD 7,000 – 14,000 |
| Surface Tension Range | 0–999.99 mN/m |
| Resolution | <0.05 mN/m |
| Measurement Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Time | 1–5 s (plate), 20–150 s (ring) |
| Interfacial Tension Capability | Yes |
| Mass Measurement Range | 0–120 g (0.1 mg resolution) |
| Power Supply | AC 220 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK2000DM |
| Measurement Range | 0–500 mN/m |
| Resolution | <0.05 mN/m |
| Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Cycle | 1–5 s (Plate), 20–150 s (Ring) |
| Temperature Control | Integrated恒温 Platform (Compatible with External Circulating Bath) |
| Sensor | Imported Japanese High-Precision Force Transducer |
| Compliance | SY/T 5370–1999 |
| Power | AC 220 V ± 22 V, 50 Hz, <150 W |
| Operating Humidity | 30–85% RH |
| Optional Modules | Magnetic Stirring, Dynamic Contact Angle, Fiber Wettability, Density & Powder Wettability Kits |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99BM |
| Measurement Range | 0–500 mN/m |
| Sensitivity | 0.01 mN/m |
| Accuracy | ±0.01 mN/m |
| Resolution | 0.01 mN/m |
| Methods | Du Noüy Ring & Wilhelmy Plate |
| Sample Volume (Ring) | 40–50 mL |
| Sample Volume (Plate) | 20–30 mL |
| Sampling Time (Ring) | 150–200 s |
| Sampling Time (Plate) | 1–5 s |
| Power Supply | AC 220 V ±5%, <150 W |
| Temperature Sensing Accuracy | ±0.1 °C |
| Relative Humidity Range | 30–85% RH |
| Interface | RS-232 Serial Port |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986 |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Model | JK99H4 |
| Surface Tension Range | 0–500 mN/m |
| Resolution | 0.05 mN/m |
| Temperature Control Range | Ambient to 400 °C |
| Temperature Accuracy | ±1 °C |
| Measurement Methods | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | 150–300 s (dual-speed adjustment) |
| Power Supply | AC 220 V ±22 V, 50 Hz |
| Power Consumption | <150 W |
| Operating Humidity | 30–85% RH |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M Series |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Primary Methods | Du Noüy Ring Method & Wilhelmy Plate Method |
| Sampling Interval | 1–5 s (plate), 20–150 s (ring) |
| Vertical Travel | 0–50 mm (standard), up to 110 mm (optional) |
| Positioning Precision | 0.1 µm |
| Data Acquisition Rate | 0.1 Hz (0.02 Hz optional) |
| Mass Measurement Range | 0–210 g (0.1 mg standard, 0.01 mg optional) |
| Temperature Sensing Accuracy | ±0.01 °C |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Method | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | Ring: 20–150 s |
| Plate | 1–5 s |
| Force Sensor | METTLER high-precision electromagnetic balance (0.1 mg / 0.01 mg optional) |
| Vertical Stage Travel | 0–50 mm (up to 110 mm optional) |
| Stage Precision | 0.1 µm |
| Speed Control | 0.1–500 mm/min |
| Temperature Monitoring | ±0.01 °C (external probe or internal liquid sensor optional) |
| Data Acquisition Rate | 0.1 Hz (0.02 Hz optional) |
| Power Supply | AC 220 ±5 V, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JK99M |
| Measurement Range | 0–1999.999 mN/m |
| Resolution & Sensitivity | 0.001 mN/m |
| Accuracy | ±0.001 mN/m |
| Method | Du Noüy Ring & Wilhelmy Plate |
| Sampling Interval | Ring method 20–150 s |
| Vertical Travel | 0–50 mm (optional 0–110 mm) |
| Positioning Precision | 0.1 µm |
| Data Acquisition Rate | 0.1 Hz (optional 0.02 Hz) |
| Temperature Sensing Precision | ±0.01 °C |
| Mass Measurement Range | 0–210 g (optional 0.01 mg resolution) |
| Power Supply | AC 220 V ±5%, <150 W |
| Operating Humidity | 30–85% RH |
| Compliance | SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JML04C1M |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer) |
| Trough Dimensions | 200 mm × 80 mm |
| Compression Ratio | up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Vertical Dipping Speed | 0.22–45 mm/min |
| Dipping Modes | Upward/Downward |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | 150 W |
| Operating Temperature | Ambient (with optional external thermostatic bath) |
| Relative Humidity | 30–85% RH |
| Software Interface | Windows-based GUI with data export, curve fitting, and post-processing capability |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JML04C2M |
| Surface Tension Range | 0–150 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Method | Wilhelmy Plate |
| Trough Material | PTFE (Full Fluoropolymer) |
| Trough Dimensions | 300 mm × 100 mm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upward & Downward |
| Power Supply | AC 220 V ±10%, 50 Hz, 150 W Max |
| Operating Temperature | Ambient (with optional external thermostatic bath) |
| Relative Humidity | 30–85% RH |
| Compliance | ASTM D971, ISO 6295, ISO 1409, USP <721>, GLP-ready data logging |
| Brand | ZYKX |
|---|---|
| Model | JPM2012M |
| Origin | Beijing, China |
| Power Supply | 220 V AC, 300 W |
| Dimensions (W×D×H) | 690 × 310 × 480 mm |
| Gas Flow Range | 0–500 mL/min (±0.5% accuracy, max pressure 0.5 MPa) |
| Foam Height Measurement | 0–280 mm via high-resolution video imaging |
| Minimum Sample Volume | 20 mL |
| Conductivity Sensing | 5-channel electrodes, resolution 0.01 µS/cm |
| Imaging System | 1300K-pixel digital camera, 25 fps, 5 mm macro lens |
| Foam Generator Pore Size (standard) | 1.0–1.6 µm |
| Temperature Control (optional) | ambient to 90 °C via integrated heating rod |
| Data Acquisition & Control | PC-based system with pre-installed proprietary software for real-time parameter configuration, curve visualization, and Excel-exportable reports |
| Optional Add-ons | top-view industrial CCD observation module, mechanical stirring foam generation unit |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | JQ03E PRO |
| Measurement Range | 0–999.999 mN/m |
| Resolution | 0.001 mN/m |
| Accuracy | ±0.01 mN/m |
| Sensitivity | 0.001 mN/m |
| Platinum Plate Method Sampling Time | 1–5 s |
| Platinum Ring Method Sampling Time | 50–200 s |
| CCD Imaging System | USB3.0 monochrome CMOS camera (1.3 MP, 54 fps), 0.7–4.5× continuous zoom, adjustable LED cold light source |
| Temperature Sensing Accuracy | ±0.1 °C (external probe optional) |
| Mass Measurement Range | 0–210 g (0.1 mg standard, 0.01 mg optional) |
| Vertical Stage Travel | 0–25 mm (0.1 mm standard, 1 µm optional) |
| Data Acquisition Rate | 0.1 s (0.02 s optional) |
| Compliance | GB/T 22237–2008, GB/T 5549–2010, GB/T 6541–1986, SY/T 5370–1999 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1100 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 20 × 20 mm |
| Optical Magnification | 55–320 pixel/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1100 °C (long-term), 1700 °C (short-term peak) |
| Vacuum Level | ≤5 × 10⁻⁵ Pa |
| Heating Rate | 3–5 °C/min |
| Temperature Control | 40-segment programmable PID with K/S/B-type thermocouples |
| Cooling System | Water-cooled, 1200 W capacity, 5–35 °C setpoint, 10–20 L/min flow rate |
| Imaging | Industrial color CCD (0.0005 lux sensitivity), 750 TV lines, 30 fps standard (upgradable to 60/100 fps), 300 mm working distance lens with 0.7–5× continuous zoom |
| Software Analysis Methods | Tangent, Circle Fit, Ellipse Fit, Height/Width, Sessile Drop, Automatic Image-Based Analysis |
| Data Output | EXCEL-compatible reports with embedded temperature metadata, curve-fitting results, left/right angle differentiation, and AVI video export |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1400 |
| Instrument Type | Benchtop Laboratory System |
| Contact Angle Measurement Range | 0° < θ < 180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 20 × 20 mm |
| Optical Magnification | 55–320 pixels/mm |
| Surface/Interfacial Tension Range | 0.01–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1400 °C (long-term), 1300 °C under vacuum |
| Base Vacuum Level | ≤5 × 10⁻⁵ Pa |
| Heating Control | 40-segment programmable PID with S-type thermocouple |
| Cooling System | Water-cooled, 1200 W capacity, flow rate 10–20 L/min, pressure 1.0–1.3 bar |
| Imaging System | Industrial color CCD (0.0005 lux sensitivity, 750 TV lines), 300 mm working distance telecentric lens, 0.7–5× continuous zoom |
| Software Analysis Methods | Tangent, Circle Fit, Ellipse Fit, Height Method, Angle Method, Automatic Image Analysis |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-1700 |
| Instrument Type | Benchtop High-Temperature Vacuum Contact Angle Measurement System |
| Contact Angle Range | 0–180° |
| Contact Angle Accuracy | ±0.1° (circle fitting method) |
| Sample Stage Dimensions | 30 × 20 mm |
| Optical Magnification | 0.7–5× |
| Surface/Interfacial Tension Range | 1–1000 mN/m |
| Surface/Interfacial Tension Accuracy | ±0.1 mN/m |
| Maximum Operating Temperature | 1700 °C (long-term: 1650 °C) |
| Ultimate Vacuum | 5 × 10⁻⁵ Pa |
| Heating Rate | 3–5 °C/min |
| Temperature Control Precision | ±1 °C (>1000 °C), ±0.1 °C (<1000 °C) |
| Cooling System | Water-cooled, 1200 W capacity, flow rate 10–20 L/min, pressure 1.0–1.3 bar |
| Imaging | Industrial color CCD, 750 TV lines, minimum illumination 0.0005 lux |
| Light Source | Adjustable cold LED backlight, >20,000 h lifetime |
| Lens | 300 mm working distance telecentric lens with continuous zoom |
| Software Analysis Methods | 6 algorithms (θ/2, tangent, circle fit, ellipse fit, height measurement, automated image analysis) |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SCI-200 |
| Price Range | USD 28,000 – 71,000 |
| Surface Tension Range | 0–500 mN/m |
| Resolution | 0.05 mN/m |
| Measurement Principle | Wilhelmy Plate Method |
| Trough Material | PTFE (Teflon®) |
| Trough Area | 30 cm × 10 cm |
| Compression Ratio | Up to 90% |
| Barrier Speed | 0.48–97 mm/min |
| Deposition Speed | 0.22–45 mm/min |
| Deposition Modes | Upward, Downward, Leftward, Rightward |
| Temperature Control Range | 5–95 °C |
| Laser Source | Adjustable 532 nm Green Laser (20 mW / 50 mW) |
| Objective | Continuous Zoom, Working Distance 90 mm, Magnification Equivalent to 700–110 px/mm, Viewing Angle 45°–60° |
| Power Supply | AC 220 V ±10%, 50 Hz, Max. 150 W |
| Brand | ZYKX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | ZYWNP-L-S01M / ZYWNP-2-0.75 / ZYWNP-3-0.75 / ZYWNP-3-1.5 / ZYWNP-3-2.2 |
| Voltage | 220 V or 380 V |
| Power | 0.25–2.2 kW |
| Flow Rate | 0.2–5.7 m³/h |
| Bubble Size Distribution Peak | 150 ± 30 nm |
| Bubble Concentration | 1×10⁷–1×10⁹ particles/mL |
| Zeta Potential | −30 to −40 mV |
| Dissolved Oxygen Increase | ≥30% vs. feed water |
| Brand | ZYKX |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYWNP-2 |
| Power Supply | 220 V |
| Rated Power | 0.37 kW |
| Average Flow Rate | 1.0 m³/h |
| Bubble Size Distribution Peak | 150 ± 30 nm |
| Bubble Concentration | 10⁷–10⁹ bubbles/mL |
| Zeta Potential | −30 to −40 mV |
| Dissolved Oxygen Increase | ≥30% |
| Operating Principle | Combined Mechanical Dispersion & Pressure-Saturation |