BrandNIUMAG
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelNM21-040H-I
Instrument TypeBenchtop Permanent-Magnet MRI System
Magnetic Field Strength0.5 ± 0.08 T
RF Coil Inner Diameter40 mm
Field of View (FOV)60 × 60 mm²
Maximum Sample Capacity1 animal per scan
Energy ResolutionNot applicable (N/A)
Spatial ResolutionNot specified in source
Scan SpeedNot quantified (system supports multi-sequence acquisition with variable TR/TE)
ComplianceDesigned for preclinical GLP-compliant research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-060H-I-1
Instrument TypeLow-Field Nuclear Magnetic Resonance (LF-NMR) Imaging System
Magnet TypePermanent Magnet
Field Strength1.0 T ± 0.05 T
Homogeneity≤30 ppm over 60 mm DSV
Sample Capacity1–350 g (mice, rats, excised tissues)
Imaging ModesT1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42
Instrument Type1.0 Tesla Permanent-Magnet Benchtop MRI System
Animal Weight Range1–45 g
Maximum Sample Width< 40 mm
Minimum Sample Volume≥ 100 µL
Minimum Slice Thickness0.8 mm
Field HomogeneityOptimized for high SNR and spatial resolution
Anesthesia CompatibilityOptional integrated gas anesthesia module
Shielding RequirementNone — no RF-shielded room required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-NIUMAG
Instrument TypePermanent-Magnet Small Animal Magnetic Resonance Imaging System
Magnetic Field Strength~1.0 T (Permanent Magnet)
Bore Diameter≥40 mm
Maximum Sample Weight45 g
Minimum Sample Volume≥100 µL
Minimum Slice Thickness0.8 mm
Imaging ModesT1-, T2-, PD-weighted, Gradient Echo, Spin Echo, Multi-slice 2D/3D acquisitions
Anesthesia CompatibilityOptional Integrated Gas Anesthesia System
Software ComplianceFDA 21 CFR Part 11–ready audit trail (optional configuration), GLP/GMP-compatible data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-040H-I
Instrument TypeMagnetic Resonance Imaging (MRI) System
Magnetic Field Strength1.0 ± 0.08 T
Magnet TypePermanent Magnet
Field Homogeneity≤20 ppm over Ø40 mm × H40 mm DSV
Imaging FOVØ40 mm × 40 mm (height)
Minimum Slice Thickness0.8 mm
Spatial Resolution (in-plane)0.08 mm
Gradient SystemHigh-Performance Integrated Gradient Set
RF Coil ConfigurationAnimal-Specific Tunable RF Coils
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-
Instrument TypeBenchtop Permanent-Magnet MRI System
Magnetic Field Strength1.0 T
Gradient PerformanceStandard for Small Animal Imaging
Minimum Slice Thickness0.8 mm
Animal Weight Capacity1–45 g
Sample Chamber Diameter≤40 mm
Minimum Sample Volume≥100 µL
Imaging ModalityProton (¹H) MRI
SafetyNon-ionizing, Non-invasive, No Radiation Exposure
Regulatory ComplianceDesigned per ISO 13485-aligned manufacturing practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginIsrael
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelM3
Instrument TypeNuclear Magnetic Resonance (NMR) Imaging System
Magnet TypePermanent Magnet, 1.0 Tesla
Field Homogeneity<10 ppm over 20 mm DSV
Gradient Strength≥200 mT/m
Gradient Slew Rate≥1000 T/m/s
Spatial Resolution≤200 µm isotropic (typical in vivo mouse brain)
Scan Time<10 minutes per standard sequence
CoolingPassive (no cryogens or chiller required)
ShieldingSelf-shielded, zero fringe field beyond instrument footprint
Regulatory ComplianceCE Marked, IEC 61000-6-3/6-4, ISO 13485–certified manufacturing processes
Software PlatformAspect ImageSuite v5.x (FDA 21 CFR Part 11 compliant audit trail optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
ModelNM42-0
Field Strength1.0 T Permanent Magnet
Maximum Sample Width<40 mm
Animal Weight Range1–45 g
Minimum Sample Volume≥100 µL
Minimum Slice Thickness0.8 mm
Imaging ModalityNuclear Magnetic Resonance (NMR)-based Magnetic Resonance Imaging (MRI)
Regulatory ClassificationPreclinical In Vivo Imaging System
Compliance FrameworkDesigned for GLP-compliant preclinical research environments
SoftwareIntegrated MRI acquisition platform with optional advanced image processing module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginIsrael
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelM3-mice
Instrument TypePreclinical Magnetic Resonance Imaging (MRI) System
Magnet TypePermanent Magnet, 1.0 Tesla
Spatial Resolution≤ 235 µm (isotropic, typical in vivo)
Scan TimeAs low as 8–9 minutes per sequence (T1- or T2-weighted)
CoolingPassive (no cryogens or chillers required)
ShieldingSelf-shielded, zero fringe field beyond system footprint
ComplianceDesigned for ISO 13485-aligned manufacturing and GLP-compliant preclinical research environments
Software PlatformAspect ImageSuite™ v5.x (FDA 21 CFR Part 11–ready audit trail, DICOM 3.0 export, multi-sequence reconstruction pipeline)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQMR12-060H-I
Instrument TypeLow-Field Nuclear Magnetic Resonance (NMR) Analyzer
Spatial Resolution0.1 mm
Field of View (FOV)100 mm × 100 mm
Magnet TypePermanent Magnet
ProbeDedicated Body Composition RF Coil
Measurement ModeNon-invasive, Anesthesia-Free, In Vivo
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginIsrael
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelM3
Instrument TypePreclinical Magnetic Resonance Imaging (MRI) System
Magnet TypePermanent Magnet, 1.0 T
Spatial Resolution≤ 235 µm (isotropic)
Scan TimeAs low as 8–9 min per sequence
CoolingPassive (No Cryogens or Chiller Required)
ShieldingSelf-Shielded, Zero Stray Field
Regulatory ComplianceCE Marked, Designed for GLP-Compliant Preclinical Research
Application FocusMouse Phenotyping, Longitudinal In Vivo Imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginIsrael
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelM5-Rat
Instrument TypeNuclear Magnetic Resonance (NMR) Imaging System
Magnet TypePermanent Magnet, 1 Tesla
Spatial Resolution≤100 µm (in-plane, 3D gradient-echo mode)
Imaging ModesT1-weighted, T2-weighted, PD-weighted, 2D/3D spin-echo and gradient-echo sequences
Application FocusIn vivo rodent musculoskeletal phenotyping, arthritis progression monitoring, preclinical OA model validation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginIsrael
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelM5
Instrument TypeNuclear Magnetic Resonance Imaging (MRI) System
Magnet TypePermanent Magnet, 1 Tesla
Weight CapacityUp to 700 g (mouse/rat)
Imaging Modes2D/3D, In Vivo, Ex Vivo, In Vitro
CoolingPassive (No Cryogens or Chiller Required)
ShieldingSelf-Shielded (Zero Stray Field)
Typical Resolution≤ 234 µm (T2-weighted), ≤ 195 µm (T1-weighted)
Acquisition Time~4.8–9.1 min per scan
ComplianceDesigned for ISO 13485-aligned lab environments