| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | NM21-040H-I |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Magnetic Field Strength | 0.5 ± 0.08 T |
| RF Coil Inner Diameter | 40 mm |
| Field of View (FOV) | 60 × 60 mm² |
| Maximum Sample Capacity | 1 animal per scan |
| Energy Resolution | Not applicable (N/A) |
| Spatial Resolution | Not specified in source |
| Scan Speed | Not quantified (system supports multi-sequence acquisition with variable TR/TE) |
| Compliance | Designed for preclinical GLP-compliant research environments |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-060H-I-1 |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (LF-NMR) Imaging System |
| Magnet Type | Permanent Magnet |
| Field Strength | 1.0 T ± 0.05 T |
| Homogeneity | ≤30 ppm over 60 mm DSV |
| Sample Capacity | 1–350 g (mice, rats, excised tissues) |
| Imaging Modes | T1-weighted, T2-weighted, Proton Density-weighted, Water-Fat Suppressed Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42 |
| Instrument Type | 1.0 Tesla Permanent-Magnet Benchtop MRI System |
| Animal Weight Range | 1–45 g |
| Maximum Sample Width | < 40 mm |
| Minimum Sample Volume | ≥ 100 µL |
| Minimum Slice Thickness | 0.8 mm |
| Field Homogeneity | Optimized for high SNR and spatial resolution |
| Anesthesia Compatibility | Optional integrated gas anesthesia module |
| Shielding Requirement | None — no RF-shielded room required |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-NIUMAG |
| Instrument Type | Permanent-Magnet Small Animal Magnetic Resonance Imaging System |
| Magnetic Field Strength | ~1.0 T (Permanent Magnet) |
| Bore Diameter | ≥40 mm |
| Maximum Sample Weight | 45 g |
| Minimum Sample Volume | ≥100 µL |
| Minimum Slice Thickness | 0.8 mm |
| Imaging Modes | T1-, T2-, PD-weighted, Gradient Echo, Spin Echo, Multi-slice 2D/3D acquisitions |
| Anesthesia Compatibility | Optional Integrated Gas Anesthesia System |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail (optional configuration), GLP/GMP-compatible data logging |
| Brand | NIUMAG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42-040H-I |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Magnetic Field Strength | 1.0 ± 0.08 T |
| Magnet Type | Permanent Magnet |
| Field Homogeneity | ≤20 ppm over Ø40 mm × H40 mm DSV |
| Imaging FOV | Ø40 mm × 40 mm (height) |
| Minimum Slice Thickness | 0.8 mm |
| Spatial Resolution (in-plane) | 0.08 mm |
| Gradient System | High-Performance Integrated Gradient Set |
| RF Coil Configuration | Animal-Specific Tunable RF Coils |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NM42- |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Magnetic Field Strength | 1.0 T |
| Gradient Performance | Standard for Small Animal Imaging |
| Minimum Slice Thickness | 0.8 mm |
| Animal Weight Capacity | 1–45 g |
| Sample Chamber Diameter | ≤40 mm |
| Minimum Sample Volume | ≥100 µL |
| Imaging Modality | Proton (¹H) MRI |
| Safety | Non-ionizing, Non-invasive, No Radiation Exposure |
| Regulatory Compliance | Designed per ISO 13485-aligned manufacturing practices |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Magnet Type | Permanent Magnet, 1.0 Tesla |
| Field Homogeneity | <10 ppm over 20 mm DSV |
| Gradient Strength | ≥200 mT/m |
| Gradient Slew Rate | ≥1000 T/m/s |
| Spatial Resolution | ≤200 µm isotropic (typical in vivo mouse brain) |
| Scan Time | <10 minutes per standard sequence |
| Cooling | Passive (no cryogens or chiller required) |
| Shielding | Self-shielded, zero fringe field beyond instrument footprint |
| Regulatory Compliance | CE Marked, IEC 61000-6-3/6-4, ISO 13485–certified manufacturing processes |
| Software Platform | Aspect ImageSuite v5.x (FDA 21 CFR Part 11 compliant audit trail optional) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Model | NM42-0 |
| Field Strength | 1.0 T Permanent Magnet |
| Maximum Sample Width | <40 mm |
| Animal Weight Range | 1–45 g |
| Minimum Sample Volume | ≥100 µL |
| Minimum Slice Thickness | 0.8 mm |
| Imaging Modality | Nuclear Magnetic Resonance (NMR)-based Magnetic Resonance Imaging (MRI) |
| Regulatory Classification | Preclinical In Vivo Imaging System |
| Compliance Framework | Designed for GLP-compliant preclinical research environments |
| Software | Integrated MRI acquisition platform with optional advanced image processing module |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3-mice |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 Tesla |
| Spatial Resolution | ≤ 235 µm (isotropic, typical in vivo) |
| Scan Time | As low as 8–9 minutes per sequence (T1- or T2-weighted) |
| Cooling | Passive (no cryogens or chillers required) |
| Shielding | Self-shielded, zero fringe field beyond system footprint |
| Compliance | Designed for ISO 13485-aligned manufacturing and GLP-compliant preclinical research environments |
| Software Platform | Aspect ImageSuite™ v5.x (FDA 21 CFR Part 11–ready audit trail, DICOM 3.0 export, multi-sequence reconstruction pipeline) |
| Brand | NIUMAG |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QMR12-060H-I |
| Instrument Type | Low-Field Nuclear Magnetic Resonance (NMR) Analyzer |
| Spatial Resolution | 0.1 mm |
| Field of View (FOV) | 100 mm × 100 mm |
| Magnet Type | Permanent Magnet |
| Probe | Dedicated Body Composition RF Coil |
| Measurement Mode | Non-invasive, Anesthesia-Free, In Vivo |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 T |
| Spatial Resolution | ≤ 235 µm (isotropic) |
| Scan Time | As low as 8–9 min per sequence |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded, Zero Stray Field |
| Regulatory Compliance | CE Marked, Designed for GLP-Compliant Preclinical Research |
| Application Focus | Mouse Phenotyping, Longitudinal In Vivo Imaging |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M5-Rat |
| Instrument Type | Nuclear Magnetic Resonance (NMR) Imaging System |
| Magnet Type | Permanent Magnet, 1 Tesla |
| Spatial Resolution | ≤100 µm (in-plane, 3D gradient-echo mode) |
| Imaging Modes | T1-weighted, T2-weighted, PD-weighted, 2D/3D spin-echo and gradient-echo sequences |
| Application Focus | In vivo rodent musculoskeletal phenotyping, arthritis progression monitoring, preclinical OA model validation |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M5 |
| Instrument Type | Nuclear Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1 Tesla |
| Weight Capacity | Up to 700 g (mouse/rat) |
| Imaging Modes | 2D/3D, In Vivo, Ex Vivo, In Vitro |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded (Zero Stray Field) |
| Typical Resolution | ≤ 234 µm (T2-weighted), ≤ 195 µm (T1-weighted) |
| Acquisition Time | ~4.8–9.1 min per scan |
| Compliance | Designed for ISO 13485-aligned lab environments |