Empowering Scientific Discovery

Suzhou Niumai Analytical Instrument Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Region of ManufactureDomestic (China)
ModelQMR
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-060H+
PricingUpon Request
Magnetic Field Strength1.0 ± 0.05 T
Larmor Frequency~42 MHz
Animal RF Coil ID60 mm
Primary ApplicationsIn vivo murine MRI for oncology, obesity, contrast agent development, and longitudinal disease modeling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelQMR06-090H-PRO
Instrument TypeResearch-Grade Small Rodent Analyzer
Sample Capacity800 g
Magnet TypePermanent Magnet
Measurement PrincipleLow-Field Nuclear Magnetic Resonance (LF-NMR)
Species CompatibilityLive Rats, Mice, and Rabbits
Measurement Time≤ 60 s per sample
Measured ParametersFat Mass, Lean Body Mass, Free Water Content
Sample PreparationNon-invasive, No Anesthesia or Euthanasia Required
SoftwareIntegrated LF-NMR Acquisition & Quantification Suite with GLP-Compliant Audit Trail
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQMR Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Magnet TypePermanent Magnet
Field Strength1.0 T
Minimum Slice Thickness0.8 mm
Animal Weight Capacity1–45 g
Sample Diameter Limit< 40 mm
Minimum Sample Volume≥ 100 µL
Scan OrientationArbitrary Angle & Arbitrary Plane
ComplianceDesigned for Preclinical GLP-Compatible Workflow
Optional ModulesGas Anesthesia System, ROI Analysis Software Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQMR06-090H
Instrument TypeResearch-Grade Small Rodent Analyzer (Mouse/Rat)
Magnet TypePermanent Magnet
Measurement Time< 60 s per animal
Sample RequirementLive, conscious, unrestrained
Measured ParametersFat Mass, Lean Body Mass, Free Water Content
Species CompatibilityMus musculus, Rattus norvegicus, Oryctolagus cuniculus
Regulatory ContextDesigned for GLP-compliant preclinical research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQMR1
Instrument TypeResearch-Grade Small Animal (Mouse) Body Composition Analyzer
Measurement PrincipleLow-Field Nuclear Magnetic Resonance (LF-NMR) Relaxometry
Sample StateConscious, Non-Invasive, Anesthesia-Free
Typical Scan Time60–180 s per mouse
Output ParametersFat Mass (g), Lean Mass (g), Total Water Mass (g), %Fat, %Lean, %Water
Magnet SystemPermanent Magnet (0.3–0.5 T typical range)
RF ProbeDedicated Quadrature Mouse-Sized RF Coil
SoftwareNIUMAG Small Animal Body Composition Analysis Suite (v4.x+)
Regulatory ComplianceDesigned for GLP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelQMR Series
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Instrument TypeResearch-Grade Small Animal (Mouse/Rat) Body Composition Analyzer
Sample CapacityLive Mice and Rats
Primary MeasurementFat Mass, Lean Body Mass, Free Water Content
Magnet TypePermanent Magnet
Test Duration≤ 60 s per animal
Sample PreparationNone (Non-invasive, Non-anesthetized, Non-terminal)
Compliance ContextDesigned for GLP-aligned preclinical metabolic phenotyping workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-060H
Instrument TypePreclinical Magnetic Resonance Imaging (MRI) System
Static Field Strength1.0 ± 0.05 T
Larmor Frequency~42 MHz
Bore Diameter60 mm
Application ScopeIn vivo MRI of mice and rats using MR contrast agents
Target ApplicationsSpontaneous tumor detection (brain, subcutaneous, liver), longitudinal tumor growth & therapy response monitoring, obesity phenotyping, MR contrast agent development
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelQMR06-060H-PRO
Instrument TypeResearch-Grade Small Animal (Mouse/Rat) Analyzer
Sample CapacitySingle mouse (up to 50 g) or rat (up to 300 g)
Core FunctionsIn vivo quantification of fat mass, lean body mass, and total body water
Magnet SystemPermanent magnet (low-field, ~0.06 T)
Measurement Time≤ 60 s per scan
Sample PreparationNon-invasive, no anesthesia, no euthanasia required
ComplianceDesigned for GLP-compliant preclinical research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Regional CategoryDomestic (China)
ModelQMR06-090H-PRO
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Magnet TypePermanent Magnet
ApplicationIn Vivo Rodent Metabolism Quantification (Mice, Rats, Rabbits)
Measurement Time1–3 min per scan
Sample StateConscious, Non-Invasive, No Anesthesia or Sacrifice Required
Core Output ParametersFat Mass, Lean Body Mass, Total Body Water (TBW)
Compliance ContextDesigned for GLP-aligned preclinical research workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42+
Instrument TypePreclinical MRI System for Rodent Research (Mouse/Rat)
Resonance Frequency~42 MHz
Static Magnetic Field Strength1.0 ± 0.05 T
Bore Diameter60 mm (Dedicated Animal RF Coil)
Magnet TypePermanent Magnet
Application ScopeIn vivo cell tracking, contrast agent evaluation, tumor modeling, metabolic phenotyping, longitudinal studies in mice and rats
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Magnet TypePermanent Magnet
Animal CompatibilityLive mice, rats, rabbits
Measurement Time< 60 s per subject
Output ParametersFat Mass, Lean Body Mass, Total Body Water
Regulatory ComplianceDesigned for GLP-compliant preclinical research environments
SoftwareProprietary NMR quantification suite with audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic Instrument
ModelQMR06 Series
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Magnet TypePermanent Magnet
Sample TypesLive rats, mice, rabbits
Measurement Time≤ 60 s per scan
Measured ParametersFat mass, lean tissue mass, free water content
SoftwareIntegrated proprietary NMR quantification platform with GLP-compliant audit trail
ComplianceDesigned for ISO/IEC 17025-aligned laboratory environments
Hardware ArchitectureBenchtop low-field NMR system (0.06–0.09 T)
Sample HandlingNon-invasive, non-destructive, no anesthesia or euthanasia required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelQMR06-060H-PRO
PricingAvailable Upon Request
Magnet TypePermanent Magnet
Sample TypesLive rats, mice, rabbits
Measurement Time≤ 60 seconds per animal
Measured ParametersFat mass, lean tissue mass, free water content
Sample PreparationNone required (non-invasive, conscious or lightly restrained animals)
ComplianceDesigned for GLP-compliant preclinical research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelNM42-060H-I
QuotationUpon Request
Magnetic Field Strength1.0 ± 0.05 T
Larmor Frequency~42 MHz
Dedicated Animal RF Coil Diameter60 mm
Species CompatibilityLive mice and rats
Primary ApplicationIn vivo glioma modeling, tumor progression monitoring, therapeutic response assessment, contrast agent evaluation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQMR06-090H
Instrument TypeIn Vivo Small Animal (Rat/Mouse) Body Composition Analyzer
Sample Capacity≤800 g
Core FunctionsFat Mass, Lean Body Mass, Total Body Water Quantification
ConstructionBenchtop Permanent-Magnet NMR System
Magnet TypePermanent Magnet
Measurement Time<60 s per scan
Sample RequirementConscious, Unanesthetized, Non-invasive
Regulatory ComplianceDesigned for GLP-aligned preclinical research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelQMR06-090H
Instrument TypeResearch-Grade Small Animal (Mouse/Rat) Body Composition Analyzer
Sample Capacity60 mm Bore — 10–100 g
Core FunctionsIn vivo quantification of total fat mass, lean tissue mass, and free water content
Magnet SystemPermanent Magnet (Low-Field, ~0.3–0.5 T typical for QMR platforms)
Measurement Time≤ 60 s per subject
Sample PreparationNone — conscious or lightly restrained live animals only
Regulatory ContextDesigned for GLP-compliant preclinical research environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelQMR Series
Instrument TypeResearch-Grade Small Animal (Mouse/Rat) Analyzer
Core MagnetPermanent Magnet
Measurement PrincipleQuantitative Low-Field NMR Relaxometry
SoftwareNIUMAG Proprietary Mouse Body Composition Analysis Suite
ComplianceDesigned for GLP-aligned preclinical metabolic studies
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Magnet TypePermanent Magnet
Sample TypeLive Rodents (Mice, Rats, Rabbits)
Measurement Time< 60 s per sample
Measured ParametersFat Mass, Lean Mass, Free Water Content
SoftwareIntegrated QMR Analysis Suite with GLP-Compliant Audit Trail
Regulatory ComplianceDesigned to support ISO/IEC 17025-aligned workflows and FDA 21 CFR Part 11–ready data integrity architecture
Application ScopePreclinical metabolic phenotyping, longitudinal obesity/diabetes studies, pharmacological intervention monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNIUMAG
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelNM42-060H-I
Magnetic Field Strength1.0 ± 0.05 T
Larmor Frequency~42 MHz
Gradient Coil Bore Diameter60 mm
Magnet TypePermanent Magnet
Application ScopeIn vivo small animal MRI (mouse/rat), contrast agent evaluation, tumor monitoring (brain, subcutaneous, liver), obesity phenotyping, longitudinal therapeutic response assessment
ComplianceDesigned for GLP-aligned preclinical research environments
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0