Temperature & Humidity Detector
Filter
Showing 181–210 of 351 results
| Brand | PST |
|---|---|
| Origin | Switzerland |
| Model Range | HF1 / HF3, CRP5 Series, HF5 / HF5-EX |
| Output Options | Analog (4–20 mA / 0–10 V) and Digital (RS485 Modbus RTU, optional BACnet MS/TP) |
| Enclosure Rating | IP65 (standard), IP67 (HF5-EX variant) |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| Accuracy | ±0.8 %RH (typ. at 23 °C, 30–70 %RH), ±0.15 °C (typ. at 23 °C) |
| Probe Configuration | Interchangeable or Fixed Integrated Sensing Elements |
| Certifications | CE, RoHS, ATEX II 2G Ex db IIB T4 Gb (HF5-EX), UL Listed (pending for HF5 series) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WT |
| Pricing | Available Upon Request |
| Probe Material | Stainless Steel |
| Probe Length | 30 cm |
| Temperature Range | −6 °C to 41 °C |
| Accuracy | ±0.2 °C |
| Response Time (in water) | 5–8 min to thermal equilibrium |
| Maximum Readout Delay Post-Extraction | 20 s |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | V-2156-X |
| Certification | ISO/IEC 17025 (A2LA & UKAS accredited) |
| Traceability | NIST-traceable |
| Application | Calibration reference for black panel temperature sensors in accelerated weathering testers |
| Replacement part type | Field-replaceable sensor assembly |
| Compatibility | QUV accelerated UV weathering testers and Q-SUN xenon arc test chambers |
| Brand | Qilin |
|---|---|
| Model | QL-TS-2 |
| Measurement Range (Fast) | 500–1999 °C |
| Continuous Range | 200–1999 °C |
| Thermocouple Type | S, B, R, WRe3/25 |
| Display | 3.5-digit, 5-inch high-brightness red LED (digit height: 127 mm) |
| Operating Temperature | 0–55 °C |
| Storage Temperature | −40–85 °C |
| Humidity (Operating) | <85% RH |
| Humidity (Storage) | <95% RH |
| Power Supply | AC 220 V / 50 Hz, 20 W |
| Dimensions (Single-Side) | 400 × 300 × 110 mm |
| Dimensions (Dual-Side) | 400 × 300 × 130 mm |
| Wireless Band | 868 MHz ISM |
| Line-of-Sight Transmission Distance | ≤200 m |
| Sampling Interval | 20 ms |
| Data Storage | 200 records |
| Output Interfaces (Configurable) | RS485, RS232, isolated BCD, 4–20 mA analog, DC12V audio alarm, thermal printer port |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41003 |
| Dimensions | 12 cm (D) × 27 cm (H) |
| Weight (net) | 0.7 kg |
| Mounting | U-bolt clamp for masts up to 2 inches (50.8 mm) diameter |
| Sensor compatibility | 41003 — up to 16 mm diameter |
| Radiative error (at 1080 W/m² solar irradiance) | ≤0.4 °C RMS @ 3 m/s wind speed |
| Housing material | UV-stabilized white thermoplastic with high-reflectivity, low-thermal-conductivity disk |
| Compliance | Designed per WMO Guide to Meteorological Instruments and Methods of Observation (CIMO Guide), ISO 4690:2022 (Environmental monitoring — Performance requirements for radiation shields), ASTM D7237-21 (Standard Practice for Evaluation of Radiation Shields for Air Temperature Sensors) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Measurement Range | −50 to +50 °C |
| Accuracy (at 0 °C) | ±0.3 °C (standard), ±0.1 °C (optional) |
| Time Constant | 42 s (with 43408 radiation shield) |
| Sensor Type | 1000 Ω Pt RTD, 4-wire configuration |
| Output Options | Resistance (41342), 0–1 VDC (41342VC), 4–20 mA (41342LC) |
| Calibration | Selectable °C or °F |
| Recommended Radiation Shield | 43502 (aspirated) or 41003P (multi-plate passive) |
| Recommended Cable | 2-pair shielded, 22 AWG (P/N 18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342LC |
| Output Signal | 4–20 mA |
| Measurement Range | −50 to +50 °C |
| Accuracy (at 0 °C) | ±0.3 °C (±0.1 °C optional) |
| Time Constant | 42 s (with Model 43408 radiation shield) |
| Sensor Type | 1000 Ω Pt RTD (IEC 60751 Class B, standard |
| Enclosure | Weatherproof junction box |
| Calibration | Configurable for °C or °F output scaling |
| Recommended Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate passive) |
| Cable Recommendation | 2-pair shielded, 22 AWG (e.g., Part #18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342VC |
| Output Signal | 0–1 VDC |
| Sensor Type | Pt1000 RTD (4-wire) |
| Measurement Range | −50 to +50 °C |
| Accuracy @ 0 °C | ±0.3 °C (standard), ±0.1 °C (optional) |
| Time Constant | 42 s (with Model 43408 radiation shield) |
| Calibration Options | °C or °F |
| Enclosure | Weatherproof terminal housing |
| Recommended Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate passive) |
| Recommended Cable | 2-pair shielded, 22 AWG (e.g., Part #18641) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382LC2 |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C (@ 23 °C) |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH (@ 20 °C) |
| RH Stability | <1 %RH/year |
| RH Response Time | 10 s (unshielded) |
| Temperature Response Time | 10 s (unshielded) |
| Output Signal | 4–20 mA (2-wire loop-powered) |
| Supply Voltage | 12–30 VDC |
| Max Current Draw | 46 mA |
| Sensor Type | Pt100 RTD (temperature), Rotronic Hygromer® (humidity) |
| Enclosure Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Recommended Cable | 2-pair shielded, 22 AWG |
| Optional Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41382VC |
| Temperature Range | -50 to +50 °C |
| Temperature Accuracy | ±0.3 °C @ 23 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±1 %RH @ 20 °C |
| RH Stability | <1 %RH/year |
| Response Time (with radiation shield) | 10 s |
| Output Signal | 0–1 VDC or 0–5 VDC (jumper-selectable) |
| Power Supply | 12–30 VDC |
| Operating Ambient Temperature | -50 to +50 °C |
| Dimensions | Ø64 mm × 176 mm |
| Weight | 200 g |
| Sensor Type (Temp) | Platinum RTD (Pt1000) |
| Sensor Type (RH) | Rotronic Hygromer® capacitive polymer |
| Recommended Cable | 5-conductor shielded (Young P/N 18723) |
| Optional Radiation Shields | 43502 (aspirated), 41003P (multi-layer passive) |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41502 |
| Material | UV-stabilized white thermoplastic housing, anodized aluminum support frame, stainless steel mounting hardware |
| Dimensions | 20 cm (diameter) × 33 cm (height) |
| Net Weight | 1.1 kg |
| Shipping Weight | ~2.7 kg |
| Power Supply | 12–14 VDC @ 500 mA |
| Airflow Rate | 5–11 m/s (16–35 ft/s), dependent on sensor power draw |
| Radiative Error (Temperature) | ≤0.2 °C RMS at 1000 W/m² solar irradiance |
| Delta-T Error | ≤0.05 °C RMS under identical shielding exposure |
| Fan Lifetime | >80,000 hours continuous operation at 25°C |
| Sensor Compatibility | RTD-based temperature probes (e.g., 41342), combined RH/T probes (e.g., 41382) |
| Output Options | 4–20 mA or 0–1 VDC |
| Operating Environment | Outdoor, all-weather, low-wind-speed microclimates |
| Brand | RainWise |
|---|---|
| Origin | USA |
| Model | TWD |
| Temperature Range | 0–50 °C |
| Accuracy | ±0.15 °C |
| Resolution | 0.10 °C |
| Sensor Type | Precision Thermistor |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RS-HW-N01 |
| Instrument Type | Fixed-mount |
| Power Supply | 10–30 V DC |
| Power Consumption | 0.4 W |
| Sensor Type | Dual-element pyroelectric infrared (PIR) sensor |
| Alarm Duration Options | 5 s / 10 s / 30 s (configurable) |
| Delay-on-Alarm | Software-configurable |
| Mounting Method | Ceiling-mounted |
| Installation Height | 2.5–6 m |
| Detection Range | Ø6 m (at 3.6 m mounting height) |
| Detection Pattern | Omnidirectional 360° horizontal coverage |
| Output Interface | RS-485 |
| Communication Protocol | Modbus-RTU |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| RFI Immunity | 20–1000 MHz |
| Microcontroller | 8-bit low-power CMOS |
| Auto Temperature Compensation | Yes |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | RS-WD-*-2 |
| Pricing | Upon Request |
| Power Supply | 10–30 V DC |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Default Accuracy | ±0.5 °C @ 25 °C |
| Operating Ambient Temp | −40 °C to +60 °C |
| Probe Temp Range | −40 °C to +120 °C (varies by probe type) |
| Humidity Range (probe) | 0–99 %RH |
| Long-Term Stability | ≤0.1 °C/year |
| Response Time | ≤10 s (at 1 m/s airflow) |
| Load Capacity | ≤600 Ω (current), ≤250 Ω (voltage) |
| Enclosure Type | IP65-rated wall-mounted “Wangzi” (character-style) housing |
| Mounting | Screw + anchor (included) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | RS-WS-DY |
| Communication | FHSS Radio (868 MHz ISM Band) |
| Display | 2.8" LCD with Real-Time Temp/RH/Time/Address/Storage Status |
| Power Supply | 10–30 V DC (AC/DC Adapter Included for 220 V AC Input) |
| Operating Temperature (Electronics) | −20 °C to +60 °C |
| Operating Humidity (Electronics) | 0–80 %RH |
| Sensor Operating Range (Standard Probe) | −40 °C to +80 °C, 0–99 %RH |
| Sensor Operating Range (Optional −B Wide-Temp Probe) | −40 °C to +120 °C |
| Accuracy (Class A) | ±0.4 °C @ 25 °C, ±2 %RH @ 25 °C (5–95 %RH) |
| Accuracy (Class B, Default) | ±0.5 °C @ 25 °C, ±3 %RH @ 25 °C (5–95 %RH) |
| Resolution | 0.1 °C / 0.1 %RH |
| Long-Term Drift | ≤0.1 °C/year, ≤1 %RH/year |
| Response Time (Standard Probe) | ≤25 s (Temp), ≤8 s (RH) at 1 m/s airflow |
| Response Time (−B Probe) | ≤18 s (Temp), ≤6 s (RH) at 1 m/s airflow |
| Data Storage Capacity | 65,535 records |
| Recording Interval | 1–65,535 minutes (configurable, default 30 min) |
| Storage Duration (at 30-min interval) | ~4 years |
| Storage Mode | Auto-cyclic overwrite |
| Alarm Outputs | 2 programmable relay outputs (NO/NC), 1 internal buzzer (85 dB), optional external sound-light alarm interface |
| Calibration | Password-protected on-device offset calibration for temperature and humidity |
| Compliance | FCC Part 15 Subpart C, CE RED Directive 2014/53/EU, RoHS 2011/65/EU |
| Wireless Protocol | Proprietary FHSS (Frequency-Hopping Spread Spectrum), 868 MHz, 100 kbps data rate |
| Line-of-Sight Range | ≥800 m |
| Wall Penetration | 3–4 reinforced concrete walls |
| Max Nodes per RS-JSQ-W Gateway | 200 units |
| Enclosure Rating | IP65 (housing), IP67 (optional −B and −6 waterproof probe variants) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | RS-YS-GPRS-Y-LY |
| Price | USD 105 (approx.) |
| Brand | RM Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Sensor Type | 1000 Ω Pt RTD (Class A) |
| Output Options | 4-wire Pt RTD / 0–1 VDC (5 mA, 8–24 VDC supply) / 4–20 mA (20 mA, 12–30 VDC supply) |
| Temperature Range | –50 to +50 °C |
| Calibration Accuracy at 0 °C | ±0.3 °C (NIST-traceable certificate included) |
| Optional Enhanced Accuracy | ±0.1 °C |
| Recommended Radiation Shields | Gill 41003P Passive Multi-Plate Shield or 43502 Active Ventilated Shield |
| Compliance | NIST-traceable calibration, ISO/IEC 17025-compliant calibration procedures |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | HC2-S3 |
| Pricing | Available Upon Request |
| Temperature Sensing Element | Pt100 RTD (IEC 60751 Class B, 1/3 tolerance) |
| Temp. Range | −40 to +60 °C |
| Temp. Accuracy | ±0.1 K at 23 °C (standard) |
| Humidity Range | 0–100 % RH |
| RH Accuracy | ±0.8 % RH (3-point calibration: 10, 35, 80 % RH) / ±0.5 % RH (9-point calibration: 10–90 % RH in 10 % steps) |
| Operating Environment | −50 to +100 °C, 0–100 % RH |
| Supply Voltage | 3.2–5 VDC or 12 VDC |
| Output Signal | 0–1 VDC analog voltage |
| Connector | Stainless steel military-grade aviation connector (MIL-C-5015 compliant) |
| Brand | SETA |
|---|---|
| Origin | United Kingdom |
| Model | ASTM Series / IP Series |
| Temperature Range | ASTM: 1 °C to 137 °C |
| IP | 1 °C to 102 °C |
| Compliance | ASTM D129, D86, D95, D126, D4294 |
| Construction | Fully Immersed, Total-Immersion Mercury-in-Glass or Precision Alcohol-Filled Capillary Thermometers |
| Calibration | Individually Certified to NIST-Traceable Standards |
| Accuracy | ±0.1 °C (typical for Class A reference thermometers per ASTM E77 and ISO 17025) |
| Graduation | Fine-etched Scale with 0.1 °C or 0.2 °C Minor Divisions |
| Stem Design | Standard or Partial Immersion, Depending on ASTM/IP Specification Requirement |
| Brand | Biaozhuo |
|---|---|
| Origin | Shanghai, China |
| Model | YCM-T |
| Measurement Range | 0–2000 pS |
| Expanded Uncertainty | ≤1% (k=2) |
| Dimensions (L×W×H) | ≤250 mm × 170 mm × 180 mm |
| Weight | ≤2.5 kg |
| Interface | BNC + Terminal Block |
| Insulation Resistance (between terminals) | ≥1×10¹³ Ω·m |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TMTI 2 |
| Pricing | Available Upon Request |
| Field of View | 20° × 15° |
| Detector Resolution | 160 × 120 uncooled microbolometer |
| Spectral Range | 8–14 µm |
| Thermal Sensitivity (NETD) | ≤0.15 °C at 25 °C |
| Temperature Range | −10 °C to +250 °C |
| Accuracy | ±2 °C or ±2% of reading (whichever is greater) |
| Minimum Focus Distance | 30 cm |
| Focus | Manual |
| Laser Targeting | Integrated Class II laser pointer for center-point indication |
| Display | 3.5″ LCD with LED backlight, 4 color palettes (Iron Red, Rainbow, Grayscale, High-Contrast) |
| Storage | Removable SD card (up to 1 GB), supports ≥1000 thermal images |
| Battery | Rechargeable Li-ion, 4 h continuous operation |
| Power Supply | 12 V AC adapter included |
| Interface | USB Type-B |
| Dimensions | 230 mm × 120 mm × 110 mm |
| Weight | 0.75 kg (with battery) |
| Housing | Shock-resistant engineering plastic |
| Emissivity Adjustment | 0.20–1.00 in 0.01 increments |
| Measurement Tools | Dual movable crosshairs, ΔT (delta-T) calculation |
| Mounting | Handheld or tripod-compatible (1/4″–20 UNC thread) |
| Operating Ambient | −15 °C to +45 °C, 10–90% RH non-condensing |
| Storage Ambient | −20 °C to +70 °C |
| Included Accessories | TMTI 2 imager, rechargeable battery, 12 V AC charger, 128 MB SD card, USB card reader + cable, lens dust cap, power connector, software CD (user manual + PC reporting suite), carrying strap, protective carry case |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2160 |
| Sensor Compatibility | PMA2161, PMA2162, PMA2163, PMA2164 |
| Temperature Range (varies by probe) | −40 to +150°C |
| Accuracy | ±0.35°C (within 0–70°C) |
| Long-term Stability | <0.02°C/year |
| Self-heating Power | <100 µW |
| Resolution | 0.1°C / 0.1°F / 0.1 K |
| Output Units | °C, °F, K |
| Cable Length | 1.2 m (4 ft) |
| Calibration Method | Embedded Steinhart-Hart coefficients |
| Interface Connector | RJ12 |
| Memory | Onboard non-volatile memory storing probe-specific calibration data |
| Brand | SOLY |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | 692 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Online Monitoring System |
| Infrared Resolution | 384 × 288 |
| NETD | <0.04 °C @ 30 °C |
| FOV | 28° × 21° |
| Detector Type | Uncooled Polysilicon FPA, 17 µm pixel pitch, 8–14 µm spectral response |
| Frame Rate | 50 Hz |
| Temperature Range | 20–60 °C |
| Measurement Accuracy | ≤ ±0.3 °C (with optional high-precision blackbody calibrator, ambient 15–35 °C) |
| Repeatability | ≤ ±0.5 °C |
| Thermal Image Modes | Grayscale / Iron Red / Rainbow |
| FFC Correction | Auto & Manual |
| Output Format | Standard JPEG with embedded radiometric temperature data |
| Interface | USB 2.0 |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–50 °C |
| IP Rating | IP54 |
| Power | DC 12 V (220 V AC adapter included) |
| Battery Life | >10 h (standby + continuous operation) |
| Weight | ~560 g |
| Dimensions | 97 × 145 × 93.5 mm |
| Mounting | Standard UNC 1/4"-20 tripod thread |
| Warranty | 1 year |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 800024 |
| Price | Upon Request |
| Channels | 4 independent inputs |
| Sensor Type | K-type thermocouples |
| Temperature Range | −200 °C to +1370 °C |
| Resolution | 0.1 °C |
| Accuracy | ±0.2% of reading + 1 °C (−200 to 200 °C), ±0.5% of reading + 1 °C (200 to 400 °C), ±0.2% of reading + 1 °C (400 to 1370 °C) |
| Data Logging Capacity | 16,000 readings |
| Interface | RS232 serial port |
| Power Supply | 9 V alkaline battery or optional AC adapter |
| Dimensions (L×W×H) | 18.5 × 6.4 × 3.2 cm |
| Standard Accessories | Two K-type thermocouple probes, RS232 cable, data logging software |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DVTH |
| Channel Count | Single-Channel |
| Price | USD 1,280 (FOB) |
| Display | Backlit Graphical LCD |
| Sampling Interval | 1 sec – 18 hr |
| Memory Capacity | 43,344 Data Points |
| Temp Range | −10 °C to +65 °C |
| Temp Resolution | 0.01 °C |
| Temp Accuracy | ±0.5 °C |
| RH Range | 0–99 %RH |
| RH Resolution | 0.01 %RH |
| RH Accuracy | ±2 %RH |
| Dimensions (L×W×H) | 10.2 × 7.6 × 3.8 cm |
| Interface | USB-B |
| Compliance | CE, RoHS, NIST-traceable calibration certificate supplied |
| Brand | T&D |
|---|---|
| Origin | Japan |
| Manufacturer | T&D Corporation |
| Model | 1-5020-31 |
| Channel Count | 1 |
| Temperature Range | -40 to +80 °C |
| Enclosure Rating | IP67 |
| Sensor Coating | FEP (Fluorinated Ethylene Propylene) Resin |
| Cable Length | 0.6 m |
| Interface | USB (PC), Optical Communication (with TR-50U2 base unit) |
| Power Supply | Bus-powered via USB |
| Included Accessories | USB Communication Cable, T&D Logbook Software |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A.B.C.D.E Temperature Indicating Strip |
| Pricing | Available Upon Request |
| Temperature Range | −30 °C to 260 °C |
| Accuracy | ±1 °C |
| Calibration Traceability | ISO/IEC 17025-accredited reference standards |
| Compliance | ISO 9001 certified manufacturing & quality control |
| Format | Adhesive-backed multi-point irreversible thermal indicator strip with 5 discrete temperature bands (A–E), each containing 8 calibrated temperature-sensitive elements |
| Brand | TES |
|---|---|
| Origin | Taiwan |
| Model | TES-1327 |
| Measurement Range | -35 °C to +500 °C (-31 °F to 932 °F) |
| Resolution | 0.1 °C / 0.2 °F |
| Accuracy | ±2% of reading or ±2 °C (whichever is greater) |
| Spectral Response | 6–14 µm |
| Distance-to-Spot Ratio | 12:1 |
| Emissivity Adjustment | 0.17–1.00 |
| Laser Targeting | Class II, <1 mW |
| Memory Capacity | 50 data points |
| Display | Backlit LCD |
| Auto Power-Off | ~15 seconds |
| Battery | 9V alkaline (006P) |
| Operating Environment | 0–50 °C, ≤80% RH |
| Storage | -10–60 °C, ≤70% RH |
| Dimensions | 172 × 118 × 46 mm |
| Weight | 220 g |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TES-PAPER |
| Pricing | Available Upon Request |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0516 1901 |
| Dimensions (L×W×H) | 340 × 265 × 60 mm |
| Weight | 1130 g |
| Housing Material | High-strength plastic |
| Interface | USB |
| Capacity | Simultaneous programming and readout of up to 8 compatible Testo data loggers |
| Software | Not included — sold separately |