| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | MicroPure |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | 1–5 ppb |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate | ≤ 1 L/min |
| Dimensions (W×D×H) | 305 × 300 × 455 mm (without tank) |
| Power Consumption | 0.06 kW |
| Feed Water Requirement | RO/DI/distilled water with conductivity < 5 µS/cm, TOC ≤ 50 ppb, bacteria < 100 CFU/mL, turbidity < 1.0 NTU, temperature 2–35°C, pressure 0.1–6 bar |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | LabTower TII |
| Output Flow Rate | 20 or 40 L/hr |
| Integrated Storage Tank Capacity | 100 L (conical, light-blocking polypropylene) |
| Resistivity | 10–15 MΩ·cm at 25 °C |
| TOC | < 30 ppb |
| Particulates (>0.1 µm) | < 1 particle/mL |
| Compliance | ASTM D1193 Type II, ISO 3696 Grade 2, CLSI-CLRW |
| Temperature Control Accuracy | ±0.1 °C |
| Conductivity Cell Constant | 0.01 cm⁻¹ with automatic temperature compensation |
| Pre-filtration | 5 µm sediment filter + activated carbon cartridge |
| Anti-scaling Cartridge | Integrated scale inhibition for RO membrane protection |
| RO Membrane Rejection | ≥97–99% of inorganic ions, ≥99% of organic compounds, microorganisms, and particulates |
| Final Polishing | Low-TOC, high-capacity mixed-bed ion exchange resin |
| Optional UV Module | 185/254 nm dual-wavelength germicidal lamp (for microbial control) |
| Data Interface | RS-232 with GLP-compliant audit trail and optional thermal printer support |
| User Interface | Backlit 4-line LCD display with password-protected parameter access |
| Operating Modes | Production, Standby (continuous recirculation), Cleaning |
| Tank Drainage | Full emptying via conical bottom geometry |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | LabTower RO |
| Output Flow Rate | 20 L/hr or 40 L/hr |
| Storage Tank Capacity | 100 L (HDPE, light-blocking) |
| Resistivity Monitoring | Yes (electrode constant 0.16 cm⁻¹) |
| Conductivity/Resistivity Display | Backlit LCD with tilt adjustment |
| Operating Modes | Production, Standby, Cleaning |
| Tank Level Indication | % display |
| Data Logging | RS-232 interface with optional printer support |
| GLP Compliance | Yes (audit-trail capable, password-protected parameter settings) |
| Pretreatment | Integrated antiscalant cartridge, 5 µm sediment filter, activated carbon filter |
| RO Membrane Protection | Antiscalant + carbon prefiltration |
| TOC Reduction | ≥99% |
| Particulate Removal (>0.1 µm) | ≥99% |
| Ionic Impurity Removal | ~98% |
| Application Grade | ASTM Type III Reagent Water (per ASTM D1193-20) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Pacific RO |
| Purified Water Grade | ASTM Type III |
| Ion Removal Efficiency | 98% |
| TOC Reduction | 99% |
| Particulate Removal (>0.1 µm) | 99% |
| Pre-filter Configuration | Dual 10-inch (25.4 cm) Cartridges — 5 µm Sediment Filter + Activated Carbon + Anti-scaling Column |
| Resistivity Probe Accuracy | ±0.16 cm⁻¹ |
| Display | Backlit Tilt-adjustable LCD with Real-time Resistivity/Conductivity, Tank Level (%), and Operational Mode Indication |
| Control System | Microprocessor-based with GLP-compliant Event Logging, Password-protected Settings, and RS-232 Data Export (Configurable Interval) |
| Storage Tank | Polyethylene (Pigment-free), Conical-bottom Design for Complete Drainage |
| Footprint | Benchtop or Wall-mountable |
| Flow Rates | 3 / 7 / 12 / 20 / 40 L/hr |
| Data Retention | Up to 4 Weeks of Timestamped System Events and Parameters |
| Compliance | Meets ASTM D1193-20 (Type III Water), Supports GLP/GMP Documentation Requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Ultra-Pure Water System |
| Models | 50129845, 50129688, 50129870, 50129872 |
| Purified Water Grade | ASTM Type I (ISO 3696 Grade 1) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| TOC | 1–5 ppb |
| Microbial Contamination | < 0.001 EU/mL |
| Particulates (>0.1 µm) | < 1 particle/mL |
| UV Lamp & UF Filter | Optional |
| CO₂ Absorber | Optional |
| Integrated Reservoir | 6 L (Smart2Pure 3/6), 30 or 60 L (Smart2Pure 12) |
| Circulation Pump | Integrated |
| Wall-Mountable | Yes |
| Display | Tilt-adjustable LCD |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Smart2Pure Pro UV/UF 16 LPH |
| Pure Water Grade | ASTM Type I |
| Resistivity | 1–10 MΩ·cm |
| Heavy Metals & Soluble Silica | <0.1 ppm |
| Total Organic Carbon (TOC) | 1–5 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | GenPure UV-TOC/UF xCAD |
| Price | Upon Request |
| Feed Water | Distilled / RO / DI Water |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Conductivity | 0.055 µS/cm @ 25 °C |
| TOC | 1–5 ppb |
| Endotoxin | ≤ 0.001 EU/mL |
| RNase | < 0.01 ng/mL |
| DNase | < 4 pg/µL |
| Microbial Count | ≤ 1 CFU/mL |
| Flow Rate | 0–2 L/min (continuously adjustable) |
| Dispense Volume Range | 0.01–65.0 L (programmable) |
| Real-time In-line TOC Monitoring | Yes (full-loop, non-sampling) |
| UV Lamp Intensity Monitoring | Dual-wavelength (185 nm & 254 nm) with real-time energy % display (UV intensity sensor, not timer-based) |
| Temperature Sensor Accuracy | ±0.1 °C |
| System-wide Wetted-Path Sanitization | Yes (including UF, storage loop, and distribution lines) |
| Remote Control | xCAD controller (up to 3 arms, 3 m max distance, 180° rotation, 0.8 m arm extension, max dispense flow 1.2 L/min) |
| Display | 4-line adjustable-angle LCD with auto-diagnostics, maintenance alerts, and alarms |
| Interface | RS232 for PC or dedicated printer connectivity |
| Standard Configuration | Main unit (integrated TOC analyzer, dual conductivity sensors, PT100 temperature probe, UV intensity sensor, UF module, dual-wavelength UV lamp), one integrated purification cartridge, terminal 0.22 µm filter |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Ultra-Pure Water System |
| Model | LabTower EDI |
| Pure Water Grade | ASTM Type I |
| Resistivity | 18.2 MΩ·cm |
| TOC | 1–5 ppb |
| Microbial Content | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| Flow Rate Options | 15 L/h or 30 L/h |
| Integrated Storage Tank | 100 L PE tank with recirculation loop and sterile air filter |
| UV Option | Available |
| CO₂ Absorber | Optional |
| Compliance | ASTM D1193, ISO 3696, USP <645>, GLP-ready, FDA 21 CFR Part 11–compatible data logging |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Nanopure Series |
| Flow Rate | >1.6 L/min |
| Resistivity | >18.2 MΩ·cm |
| Total Organic Carbon (TOC) | <5 ppb |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.2 µm) | <1 particle/mL |
| UV Absorbance (254 nm) | <0.0001 AU |
| Silica | <3 ppb |
| Conductivity Calibration Option | NIST-traceable module available |
| Compliance | ASTM D1193 Type I, NCCLS (now CLSI) EP21-A, CAP guidelines |
| Certifications | CSA, CE |
| Power Input | 90–240 VAC, 47–63 Hz |
| Interface | RS-232 for data logging and printer/computer connectivity |
| Remote Display | Optional wall-mount or under-bench installation supported |
| Real-time TOC monitoring | Standard |
| Brand | Thermo Fisher |
|---|---|
| Origin | Imported |
| Manufacturer | Thermo Fisher Scientific |
| Model | GenPure Pro |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25°C |
| TOC | 1–5 ppb |
| Microbial Count | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | ≤ 0.003 ng/mL |
| DNase | ≤ 0.4 pg/µL |
| UV Wavelength | 185 nm / 254 nm |
| Conductivity Sensor Electrode Constant | 0.01 cm⁻¹ |
| Temperature Accuracy | ±0.1°C |
| Dispensing Accuracy | ±0.5% (0.01–65 L) |
| Data Logging | Last 4 weeks of system errors |
| Compliance | ASTM D1193, ISO 3696, CLSI, USP <645>, GLP |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Imported (Manufactured Outside China) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | 1–5 ppb |
| Microbial Count | < 1 CFU/mL |
| Endotoxin | < 0.001 EU/mL |
| Particles (>0.1 µm) | < 1 particle/mL |
| RNase | ≤ 0.003 ng/mL |
| DNase | ≤ 0.4 pg/µL |
| UV Wavelengths | 185 nm & 254 nm |
| Flow Rate | ≤ 2 L/min (up to 1.2 L/min at point-of-use arm) |
| Dimensions (W×D×H) | 372 × 330 × 615 mm (main unit) |
| Desktop xCAD arm | 260 × 530 × 725 mm |
| Wall-mounted xCAD arm | 260 × 530 × 655 mm |
| Power Consumption | 0.1 kW |
| Inlet Requirements | RO/DI/distilled water, conductivity < 2 µS/cm (xCAD-specific), TOC ≤ 50 ppb, pressure 0.1–6 bar, temp. 2–35 °C |
| Compliance | ASTM D1193, ISO 3696, CLSI CLRW, USP <645>, GLP/GMP-ready with audit trail and password protection |
| Interface | RS-232 with configurable logging interval |
| Data Storage | Error log history for up to 4 weeks |
| Certifications | IQ/OQ documentation available (E5013318 for xCAD series) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Pacific TII |
| Output Flow Rates | 3 / 7 / 12 / 20 / 40 L/hr |
| Resistivity | 10–15 MΩ·cm at 25 °C |
| TOC | <30 ppb |
| Particulates (>0.1 µm) | <1 particle/mL |
| Display | Backlit adjustable-angle LCD with resistivity/conductivity, status mode, tank level (%), and temperature (±0.1 °C per USP <645>) |
| Conductivity Cell Constant | 0.01 cm⁻¹ |
| Compliance | GLP-supporting data logging via RS-232 printer interface |
| Installation | Benchtop or wall-mounted |
| Scalability | Field-upgradable to higher flow capacity |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | Nanopure Life Science Series |
| Pricing | Available Upon Request |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| TOC | 1–5 ppb |
| Endotoxin | <0.001 EU/mL |
| Bacterial Count | <1 CFU/mL |
| Particles (>0.2 µm) | <1 /mL |
| Silica | <1 ppb |
| UV Absorbance @ 254 nm | <0.001 AU |
| Flow Rate | 1.8 L/min |
| Feed Water Requirements | Pre-treated RO, distilled or deionized water |
| Pressure | 100 psi (6.9 bar) |
| Temperature | 4–40 °C |
| Intelligent Dispensing Range | 0.25–60 L |
| Accuracy | ±5% (≥1 L), Repeatability: ±3% |
| Conductivity Cell Constant | 0.1 cm⁻¹ |
| Temp. Sensor Accuracy | ±0.1 °C |
| Dimensions (W×H×D) | 34.3 × 49.5 × 43.2 cm |
| Installation | Benchtop or wall-mounted (included bracket) |
| Service Clearance | Side >22.9 cm, Top >7.6 cm, Front >12.1 cm |
| Power | 90–240 VAC, 100 VA, 47–63 Hz, Single Phase |
| Tubing | Feed line Ø11.43 mm (supplied), Drain line Ø7.62 mm (supplied) |