| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A214, A324 |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Modules | pH/Temp, pH/ISE/Temp, pH/LogR/Temp, Conductivity/Temp, DO/Temp |
| Data Storage | 2000–5000 entries (GLP-compliant) |
| Display | Full-color LCD with multi-parameter overlay |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 (benchtop), IP67 (portable A329) |
| Power Options | AC adapter (90–260 V AC) or 4×AA batteries |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-48 |
| Price | Upon Request |
| Electrode | 9648BNWP Cd²⁺ Composite Electrode |
| Cd²⁺ Measurement Range | 0.01–11,200 ppm |
| pH Range | 2–12 |
| Temp. Range (Continuous) | 0–80°C |
| Temp. Range (Intermittent) | 80–100°C |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm (L) × 13 mm (body Ø) × 16 mm (cap Ø) |
| Cable Length | 1 m |
| Ion Concentration Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temp. Accuracy | ±0.1°C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion2700 |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.002 pH + 1 LSD |
| pH Calibration Points | Up to 6 |
| Buffer Standards | USA, NIST, DIN, User 1, User 2, Custom |
| Ion Concentration Range | 0.001–19999 ppm (±2000.0 mV) |
| Ion Resolution | 2- or 3-digit |
| Ion Accuracy | ±0.5% of full scale (monovalent), ±1.0% of full scale (divalent) |
| Ion Calibration Points | 2–8 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| ORP/mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Compensation | Automatic or Manual (0–100 °C, pH only) |
| GLP Compliance | Yes |
| Slope/Offset Display | Yes |
| Data Storage | 500 records with timestamp |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Input Interfaces | BNC (pH/ORP/ion), Phono (ATC probe), Phono (reference electrode), DC socket |
| Output Interface | RS232C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS, 1.3 A) |
| Operating Temperature | 5–45 °C |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight (unit) | 650 g |
| Packaging Dimensions | 30.8 × 23.5 × 12.4 cm |
| Shipping Weight | 1800 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-02 |
| Electrode | 9502BNWP CO₂ Gas-Sensing Electrode |
| CO₂ Range | 4.4–440 ppm |
| pH Operating Range | 4.8–5.2 |
| Temperature Range | 0–50°C |
| Reproducibility | ±2% |
| Electrode Dimensions | 151 mm (L) × 17 mm (body Ø) × 22 mm (cap Ø) |
| Cable Length | 75 cm |
| Dual Channel Meter | pH/ISE Mode |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ISE Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| ORP Range | ±1999.9 mV |
| Temperature Range | −5 to 105°C |
| Temp Accuracy | ±0.1°C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Interface | Dual RS232 & optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Ion 6+ |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-32 |
| Pricing | Upon Request |
| Electrode System | 9332BNWP Hardness Half-Cell Electrode + 900100 Single-Junction Reference Electrode |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) Detection of Ca²⁺ and Mg²⁺ |
| pH Range | 7–10 |
| Temperature Range | 0–40 °C |
| Repeatability | ±4% |
| Ion Concentration Range | 6 × 10⁻⁶ M to 1 M (as CaCO₃ equivalent) |
| pH Range (Meter) | −2.000 to 19.999 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes (audit trail, password protection, method locking) |
| Connectivity | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Model | F090 |
| Ion Type | Fluoride |
| Measurement Range (F⁻) | 0.02–2000 ppm |
| Resolution | 0.01 ppm (<1 ppm), 0.1 ppm (1.0–199.0 ppm), 1 ppm (>200 ppm) |
| Accuracy | ±0.5% of full scale (monovalent ions) |
| pH Range | 0.00–14.00, ±0.002 pH accuracy |
| ORP Range | ±1999 mV |
| Temperature Range | 0–100 °C, ±0.5 °C accuracy |
| Calibration Points | 2–5 points |
| Data Storage | 100 sets |
| Display | Dual-line LCD (5.6 × 7.5 cm) |
| Power | 9 V DC adapter (100–220 V AC input) |
| Dimensions (instrument) | 17.5 × 15.5 × 6.9 cm |
| Weight (instrument) | 650 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | D10P-29 |
| Price | Upon Request |
| Electrode | 9629BNWP Copper ISE |
| Measurement Range | 6.4×10⁻⁴ – 6354 ppm Cu²⁺ |
| pH Range | 2–12 |
| Temp. Range | 0–80°C continuous / 80–100°C intermittent |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm length, 13 mm body dia., 16 mm cap dia., 1 m cable |
| Instrument Resolution | 1–3 sig. fig. (ion), 0.001 pH |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | D10P-26 |
| Pricing | Available Upon Request |
| Electrode | 9606BNWP Cyanide Ion-Selective Electrode |
| Measuring Range (Cyanide) | 0.2–260 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | Length 110 mm, Body Diameter 13 mm, Cap Diameter 16 mm, Cable Length 1 m |
| Main Unit Ion Concentration Range | 0–19999, Resolution: 1–3 significant digits, Accuracy: ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999, Resolution: 0.1/0.01/0.001, Accuracy: ±0.001 pH |
| ORP Range | ±1999.9 mV, Resolution: 0.1 mV |
| Temperature Measurement | −5 to 105 °C, Accuracy: ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | Dual RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Benchtop Dual-Channel Ion Concentration and pH Meter |
| Model | D10P-20 |
| Ion Measurement Range | 0–19999 (in user-selectable units: ppm, mg/L, M, %, or unitless) |
| Detection Limit | 0.1 ppm Ca²⁺ (as specified with 9720BNWP electrode) |
| Response Time | <30 s (t₉₀, typical for ISE in stirred aqueous samples) |
| Measurement Accuracy | ±0.1 mV or ±0.05% of reading (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Electrode Compatibility | Orion 9720BNWP Calcium ISE, 927007MD ATC probe |
| Compliance | GLP-compliant data logging, CE, CSA, UL, TÜV, FCC Class A, IP54 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-82 |
| Price | Upon Request |
| Electrode | 9682BNWP Lead Ion-Selective Electrode |
| Measurement Range (Electrode) | 0.2–20,700 ppm Pb²⁺ |
| pH Range | 4–7 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Repeatability | ±4% |
| Sample Type | Aqueous solutions |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter |
| Cable Length | 1 m |
| Instrument Resolution (Ion Mode) | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105°C |
| Temp. Accuracy | ±0.1°C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, two reference electrode, two MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 data sets with timestamp |
| GLP Compliance | Yes (audit trail, user ID, calibration history) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | ISE Series |
| Instrument Category | Multi-Ion Analyzers |
| Compliance | ASTM D1129, ISO 10523, USP <798>, EPA Method 300.0, EN ISO 10304-1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-16N |
| Pricing | Upon Request |
| Electrode | 9616BNWP Ag⁺/S²⁻ Combination Electrode |
| Measurement Range (S²⁻) | 0.003–32,100 ppm |
| pH Range | 2–12 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Reproducibility | ±4% for S²⁻, ±2% for Ag⁺ |
| Sample Type | Aqueous solutions |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Dual Channel Capability | pH + ISE simultaneously |
| Ion Measurement Range | 0–19,999 units |
| Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105°C |
| Temperature Accuracy | ±0.1°C (−5 to 99.9°C) |
| Display | Dual-channel LCD |
| Interfaces | Two BNC, two reference electrode ports, two MiniDIN (for ATC probes) |
| Method Storage | 20 user-defined methods |
| Password Protection | Yes |
| Data Storage | 1,000 readings with timestamp |
| GLP Compliance | Yes (audit trail, calibration history, operator ID) |
| Data Transfer | Bidirectional RS232 |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45°C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-17 |
| Instrument Category | Chloride Ion Analyzer |
| Electrode | 9617BNWP Chloride Composite Electrode |
| Measurement Range (Electrode) | 1.8–35,500 ppm Cl⁻ |
| pH Range | 2–12 |
| Temperature Range | 10–100 °C |
| Repeatability | ±2% |
| Minimum Sample Volume | 3 mL |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit | Dual Channel pH/ISE Meter |
| ISE Range | 0–19,999 (ppm, mg/L, M, %, or unitless) |
| ISE Resolution | 1–3 significant digits |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to +19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration Points | 1–6 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% |
| Temperature Range | −5 to +105 °C |
| Temp Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Inputs | Two BNC, two reference electrode ports, two MiniDIN (for ATC probes) |
| Method Storage | 20 user-defined methods |
| Password Protection | Yes |
| Data Storage | 1,000 readings with timestamp |
| GLP Compliance | Yes (audit trail, calibration history, operator ID support) |
| Data Interface | Bidirectional RS232, optional USB cable |
| Enclosure Rating | IP54 |
| Safety Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm (H) × 17.0 cm (W) × 22.4 cm (D) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Dual Star |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| Calibration Points | 1–6 |
| Auto-Buffer Recognition | US, NIST, DIN, and User-Defined |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 Significant Digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Units | ppm, mg/L, M, %, or unitless |
| Measurement Modes | Single or Dual Standard Addition/Standard Subtraction |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Temperature Range | –5 to 105 °C |
| Temp Resolution | 0.1 °C (–5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temp Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Input Interfaces | Two BNC, Two Reference Electrode, Two MiniDIN (for temperature probes) |
| Method Storage | 20 methods |
| Password Protection | Yes |
| Data Storage | 1000 readings |
| GLP Compliance | Yes |
| Data Interface | Bidirectional RS232, optional USB cable |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| Power Supply | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion700 |
| Pricing | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | Star A211 |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | D10P-53 |
| Pricing | Upon Request |
| ISE Electrode | 9653BNWP |
| Iodide Measurement Range | 0.005–127,000 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Reproducibility | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Dual-Channel Meter Resolution | 1–3 significant digits |
| Relative Accuracy (Ion) | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Units | ppm, mg/L, M, %, or unitless |
| Calibration Points | 2–6 |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range | −5 to 105 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-35 |
| Price | Upon Request |
| Electrode | 9635BNWP Bromide Composite Electrode |
| Bromide Range | 0.2–79,900 ppm |
| pH Range | 0–14 |
| Temperature Range | 0–80 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter, 1 m cable |
| Meter Resolution | 1–3 significant digits (ion mode) |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Method Storage | 20 methods |
| Data Storage | 1,000 records with timestamp |
| GLP Compliance | Yes (audit trail, password protection, user-defined methods) |
| Connectivity | Dual RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-06 |
| Instrument Category | Sodium Ion Analyzer |
| Form Factor | Benchtop |
| Measurement Range | 0–19999 (in user-selectable units) |
| Detection Limit | 0.1 ppb (with 8411BNWP electrode and flow cell) |
| Response Time | < 30 s (t₉₀, typical) |
| Accuracy | ±0.1 mV (potential) or ±0.05% of reading (whichever is greater) |
| Temperature Range | −5 to 105 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Line | Orion Star LogR Series |
| Model | LogR pH/ISE |
| Measurement Principle | Potentiometric (Glass Electrode + ISE) with LogR™ Membrane Resistance-Based Temperature Sensing |
| Compliance | ASTM D1293, ISO 10523, USP <791>, EPA Method 150.1, GLP-Ready |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported Instrument |
| Model | D10P-16 |
| Pricing | Upon Request |
| Electrode | 9616BNWP Ag⁺/S²⁻ Combination Electrode |
| Measurement Range (Ag⁺) | 0.003–32,100 ppm |
| pH Range | 2–12 |
| Temperature Range | 0–80°C (continuous), 80–100°C (intermittent) |
| Reproducibility | ±2% for Ag⁺, ±4% for S²⁻ |
| Electrode Dimensions | 110 mm length, 13 mm body diameter, 16 mm cap diameter, 1 m cable |
| Main Unit | Dual-channel pH/Ion Meter with GLP compliance, RS232 & USB connectivity, IP54 rating, 1000-data storage, 20 method memories |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | D10P-19 |
| Instrument Category | Multi-Ion Analyzer |
| Electrode | 9719BNWP Potassium Composite Electrode |
| Measurement Range (K⁺) | 0.04–39,000 ppm |
| pH Compatibility | 2.5–11 |
| Temperature Range | 0–40 °C |
| Repeatability | ±2% |
| Electrode Dimensions | 110 mm length × 13 mm body diameter × 16 mm cap diameter |
| Cable Length | 1 m |
| Main Unit Ion Range | 0–19,999 (units: ppm, mg/L, M, %, or unitless) |
| Ion Resolution | 1–3 significant digits |
| Ion Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| Temperature Range (instrument) | −5 to 105 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Dual-channel LCD |
| Interfaces | Dual BNC, dual reference electrode ports, dual MiniDIN (for ATC probes) |
| Method Storage | 20 methods |
| Data Storage | 1,000 entries with timestamp |
| GLP Compliance | Yes (audit trail, user passwords, method-level access control) |
| Connectivity | RS232 (bidirectional), optional USB cable |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Power | 4×AA batteries or universal AC adapter |
| Dimensions | 9.4 cm H × 17.0 cm W × 22.4 cm D |