- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A214, A324 |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Modules | pH/Temp, pH/ISE/Temp, pH/LogR/Temp, Conductivity/Temp, DO/Temp |
| Data Storage | 2000–5000 entries (GLP-compliant) |
| Display | Full-color LCD with multi-parameter overlay |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 (benchtop), IP67 (portable A329) |
| Power Options | AC adapter (90–260 V AC) or 4×AA batteries |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Portable |
| Measurement Principle | Amperometric Electrochemical Sensor |
| Measurable Parameters | Free Chlorine, Total Chlorine, pH, Chlorine Dioxide, Cyanuric Acid |
| Free Chlorine Range | 0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L) |
| Total Chlorine Range | 0.02–4.0 mg/L (US EPA Validated Range: 0.03–2.0 mg/L) |
| Chlorine Dioxide Range | 0–9 mg/L |
| pH Range | 5.9–8.2 |
| Cyanuric Acid Range | 5–90 mg/L |
| Sample Volume | 10 mL |
| Display | LCD |
| Power | 4×AAA batteries (≥3000 measurements, auto-off) |
| Ingress Protection | IP67 |
| Operating Environment | 0–50 °C, 0–90% RH (non-condensing at 30 °C) |
| Compliance | CE, TÜV, FCC Part 15 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-48 |
| Price | Upon Request |
| Electrode | 9648BNWP Cd²⁺ Composite Electrode |
| Cd²⁺ Measurement Range | 0.01–11,200 ppm |
| pH Range | 2–12 |
| Temp. Range (Continuous) | 0–80°C |
| Temp. Range (Intermittent) | 80–100°C |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm (L) × 13 mm (body Ø) × 16 mm (cap Ø) |
| Cable Length | 1 m |
| Ion Concentration Resolution | 1–3 significant digits |
| Relative Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temp. Accuracy | ±0.1°C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 (bidirectional), optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion2700 |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.002 pH + 1 LSD |
| pH Calibration Points | Up to 6 |
| Buffer Standards | USA, NIST, DIN, User 1, User 2, Custom |
| Ion Concentration Range | 0.001–19999 ppm (±2000.0 mV) |
| Ion Resolution | 2- or 3-digit |
| Ion Accuracy | ±0.5% of full scale (monovalent), ±1.0% of full scale (divalent) |
| Ion Calibration Points | 2–8 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| ORP/mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Compensation | Automatic or Manual (0–100 °C, pH only) |
| GLP Compliance | Yes |
| Slope/Offset Display | Yes |
| Data Storage | 500 records with timestamp |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Input Interfaces | BNC (pH/ORP/ion), Phono (ATC probe), Phono (reference electrode), DC socket |
| Output Interface | RS232C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS, 1.3 A) |
| Operating Temperature | 5–45 °C |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight (unit) | 650 g |
| Packaging Dimensions | 30.8 × 23.5 × 12.4 cm |
| Shipping Weight | 1800 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | C401 |
| Price | Upon Request |
| Chlorine Range | 0–1.99 ppm / 2.0–6.0 ppm |
| Chlorine Resolution | 0.01 ppm / 0.1 ppm |
| Chlorine Accuracy | ±0.02 ppm / ±0.2 ppm |
| pH Range | 5.9–8.2 |
| pH Resolution | 0.1 |
| pH Accuracy | ±0.1 |
| Cyanuric Acid Range | 5–90 ppm |
| Cyanuric Acid Resolution | 1 ppm |
| Cyanuric Acid Accuracy | ±4 ppm |
| Light Source | LED (525 nm) |
| Calibration | Single-point user-selectable per test |
| Operating Temperature | 0–50 °C |
| Power Supply | 4 × 1.5 V AAA batteries |
| Battery Life | >3000 measurements |
| IP Rating | IP67 |
| Dimensions (Instrument) | 15.5 × 6.8 × 4.6 cm |
| Weight (Instrument) | 200 g |
| Packaging Dimensions | 35.5 × 16.5 × 10.5 cm |
| Package Weight | 1170 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Models | 8157BNUMD (Refillable), 8107BNUMD (Low-Maintenance) |
| pH Range | 0–14 |
| pH Accuracy | ±0.03 pH (with ATC) |
| pH Precision | ±0.01 pH |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±1.0 °C |
| Reference System | ROSS™ Double-Junction |
| Internal Reference | ROSS™ Liquid Junction |
| Isopotential Point | pH 7 |
| Fill Solution (Refillable) | 3 M KCl |
| Body Material | Epoxy Resin |
| Electrode Length | 120 mm |
| Diameter | 12 mm |
| Compatible Meters | Orion Star™, Aplus™, and PerpHecT® Series |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-02 |
| Electrode | 9502BNWP CO₂ Gas-Sensing Electrode |
| CO₂ Range | 4.4–440 ppm |
| pH Operating Range | 4.8–5.2 |
| Temperature Range | 0–50°C |
| Reproducibility | ±2% |
| Electrode Dimensions | 151 mm (L) × 17 mm (body Ø) × 22 mm (cap Ø) |
| Cable Length | 75 cm |
| Dual Channel Meter | pH/ISE Mode |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ISE Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| ORP Range | ±1999.9 mV |
| Temperature Range | −5 to 105°C |
| Temp Accuracy | ±0.1°C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Interface | Dual RS232 & optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | Star A215 |
| Price | Upon Request |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, NIST/US, DIN, and user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| DO Range | 0.00–90.0 mg/L (0.0–600% saturation) |
| DO Resolution | 0.01 mg/L / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| DO Calibration | Air-saturated water, water-saturated air, Winkler titration, zero-point |
| Sensor Type | Polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Compensation | Automatic or manual |
| Display | Backlit LCD with icon-driven interface |
| Connectivity | Dual-mode RS232, optional USB cable |
| Input Interfaces | pH (BNC), temperature (miniDIN), stirrer (phono-jack, benchtop only) |
| Data Logging | 750 measurements |
| Calibration History | Last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 independent user profiles |
| Power | 4×AA alkaline batteries (up to 2000 h portable operation) or universal AC adapter (benchtop) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Environmental Rating | Benchtop IP54 (dust- and splash-resistant) |
| Dimensions (Benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (Portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Ion 6+ |
| Price | Upon Request |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech DO2700 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Range Accuracy | ±0.5% of full scale |
| Resolution (DO) | 0.01 mg/L |
| Saturation Range | 0–600% |
| Temperature Range | 0.0–50.0 °C |
| Temp. Accuracy | ±0.3 °C |
| Salinity Compensation | 0–50 ppt |
| Barometric Pressure Compensation | 450–825 mmHg (auto) |
| Data Storage | 500 GLP-compliant records with timestamp |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Interface | RS232 (bidirectional), 8-pin probe connector, DC socket |
| Power | 9 V regulated adapter (100–240 VAC SMPS) |
| Dimensions (unit) | 17.5 × 15.5 × 6.9 cm |
| Weight (unit) | 650 g |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Dual Star |
| Pricing | Available Upon Request |
| Ammonia Electrode | 9512BNWP |
| Measurement Range | 0.01–17,000 ppm (as N) |
| Temperature Range | 0–50 °C |
| Electrode Slope | −54 to −60 mV/decade (at 25 ± 4 °C, ΔT < ±1 °C between solutions) |
| Repeatability | ±2% |
| Ion Concentration Resolution | 1–3 significant digits |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.001 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Communication | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-32 |
| Pricing | Upon Request |
| Electrode System | 9332BNWP Hardness Half-Cell Electrode + 900100 Single-Junction Reference Electrode |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) Detection of Ca²⁺ and Mg²⁺ |
| pH Range | 7–10 |
| Temperature Range | 0–40 °C |
| Repeatability | ±4% |
| Ion Concentration Range | 6 × 10⁻⁶ M to 1 M (as CaCO₃ equivalent) |
| pH Range (Meter) | −2.000 to 19.999 |
| ORP Range | ±1999.9 mV |
| Temperature Accuracy | ±0.1 °C |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes (audit trail, password protection, method locking) |
| Connectivity | RS232 and optional USB |
| Enclosure Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable/HANDHELD Water Quality Analyzer |
| Model | PD650 |
| Measurement Parameters | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen (DO), Temperature |
| IP Rating | IP67 |
| Accuracy (pH) | ±0.002 pH |
| Conductivity Accuracy | ±1% of full scale + 1 LSD |
| DO Range | 0.00–90.00 mg/L |
| Data Storage | 500 GLP-compliant entries |
| Auto-Range Conductivity | 5 ranges up to 500 mS/cm |
| Electrode Recognition | Automatic 2-/4-cell conductivity cell detection |
| Built-in Barometer | Yes |
| Wireless Capability | IrDA & RS232C |
| Battery Life | >200 hours |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Model | F090 |
| Ion Type | Fluoride |
| Measurement Range (F⁻) | 0.02–2000 ppm |
| Resolution | 0.01 ppm (<1 ppm), 0.1 ppm (1.0–199.0 ppm), 1 ppm (>200 ppm) |
| Accuracy | ±0.5% of full scale (monovalent ions) |
| pH Range | 0.00–14.00, ±0.002 pH accuracy |
| ORP Range | ±1999 mV |
| Temperature Range | 0–100 °C, ±0.5 °C accuracy |
| Calibration Points | 2–5 points |
| Data Storage | 100 sets |
| Display | Dual-line LCD (5.6 × 7.5 cm) |
| Power | 9 V DC adapter (100–220 V AC input) |
| Dimensions (instrument) | 17.5 × 15.5 × 6.9 cm |
| Weight (instrument) | 650 g |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BOD AutoEZ |
| Instrument Type | Laboratory BOD Analyzer |
| Measurement Principle | Microbial Electrode Method |
| Sample Capacity | Up to 36 samples per run (3 trays × 12 BOD bottles) |
| Analysis Time | ~15 minutes for full 36-sample batch |
| Electrode Configuration | Patented quad-electrode, 4-channel dissolved oxygen sensing |
| Report Generation | Fully automated BOD calculation and PDF/CSV export |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | VERSA STAR |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ISE (Ion Selective Electrode), Conductivity, Dissolved Oxygen (DO), Temperature |
| Compliance | GLP-Compliant Data Storage (2000 Records) |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 |
| Operating Modules | Up to 4 Simultaneous Modules |
| Stirrer Support | 2 Orion Star Stirrers (Hot-Swappable) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | A216 (Benchtop) / A326 (Portable) |
| Instrument Type | Laboratory |
| pH Range | −2.000 to 20.000 |
| pH Accuracy | ±0.001 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| mV Range | ±2000.0 mV |
| mV Accuracy | ±0.1 mV |
| DO Measurement Principle | Polarographic or Luminescent (RDO) |
| Polarographic DO Range | 0–90 mg/L (±0.2 mg/L accuracy) |
| RDO DO Range | 0–50 mg/L (±0.1 mg/L @ 0–8 mg/L |
| DO Saturation Range | 0–600% (Polarographic) / 0–500% (RDO) |
| DO Saturation Accuracy | ±2% |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Temp Accuracy | ±0.1 °C |
| Data Storage | 2000 entries (A216) / 5000 entries (A326), with timestamp, sample ID, user ID, and calibration metadata |
| Compliance | GLP-compliant data logging, FDA 21 CFR Part 11-ready audit trail support via optional software |
| Enclosure Rating | IP54 (A216), IP67 (A326) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | A213 (Benchtop), A223 (Portable) |
| Measurement Principle | Electrochemical (Galvanic Cell) and Optical (RDO Fluorescence) |
| DO Range | 0–90 mg/L (Galvanic), 0–50 mg/L (RDO) |
| Accuracy | ±0.2 mg/L (Galvanic) |
| Saturation Range | 0–600% (Galvanic), 0–500% (RDO) |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Temperature Range | 0–50 °C |
| Resolution | 0.01/0.1 mg/L |
| Data Storage | 2000 entries (A213), 1000 entries (A223), GLP-compliant |
| Interface | RS232, USB |
| Power | AC adapter (100–240 V AC) or 4 × AA batteries |
| IP Rating | IP54 (A213), IP67 (A223) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Eutech Instruments (a Thermo Fisher brand) |
| Type | Laboratory Water Quality Analyzer |
| Model | PC700 |
| Category | Environmental Monitoring Instrument |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable |
| Measurement Principle | Polarographic & Luminescent (RDO) |
| DO Range | 0–90 mg/L (polarographic), 0–50 mg/L (RDO) |
| Accuracy | ±0.2 mg/L (polarographic), ±0.1–±0.2 mg/L + 10% (RDO) |
| Saturation Range | 0–600% (polarographic), 0–500% (RDO) |
| Temperature Range | 0–50 °C |
| Temp Accuracy | ±0.1 °C |
| Atmospheric Pressure Compensation | 450.0–850.0 mmHg |
| Salinity Correction | 0–45 ppt |
| Data Storage | 2000 datasets (GLP-compliant) |
| IP Rating | IP67 |
| Interface | 9-pin mini-DIN probe port, USB, RS232 |
| Power | 4 × AA batteries or AC adapter |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCD650 |
| Pricing | Upon Request |
| Instrument Type | Laboratory-Grade Portable Water Quality Analyzer |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Eutech DO700 |
| Price | Available Upon Request |
| DO Range | 0–30.0 mg/L |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±0.5% of full scale |
| % Saturation Range | 0–199.9% / up to 300% |
| % Saturation Resolution | 0.1% |
| % Saturation Accuracy | ±0.5% of full scale |
| Salinity Compensation Range | 0–50 ppt |
| Salinity Resolution | 0.1 ppt |
| Barometric Pressure Adjustment Range | 450–825 mmHg |
| Barometric Resolution | 1 mmHg |
| Temperature Range | 0.0–50.0 °C (32.0–122.0 °F) |
| Temperature Resolution | 0.1 °C/°F |
| Temperature Accuracy | ±0.5 °C / ±0.9 °F |
| Data Storage Capacity | 100 measurement records |
| Auto-Stability Indicator | Yes |
| Display | Large backlit LCD |
| Includes | Electrode stand |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A329 |
| Instrument Type | Portable Multiparameter Water Quality Analyzer |
| Compliance | GLP-Compliant Data Logging (5000 Entries) |
| Protection Rating | IP67 |
| Power | 4×AA Batteries or AC Adapter |
| Connectivity | USB & RS232 |
| Software Support | Orion™ Comli Software (FDA 21 CFR Part 11 Ready) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | D10P-29 |
| Price | Upon Request |
| Electrode | 9629BNWP Copper ISE |
| Measurement Range | 6.4×10⁻⁴ – 6354 ppm Cu²⁺ |
| pH Range | 2–12 |
| Temp. Range | 0–80°C continuous / 80–100°C intermittent |
| Reproducibility | ±4% |
| Electrode Dimensions | 110 mm length, 13 mm body dia., 16 mm cap dia., 1 m cable |
| Instrument Resolution | 1–3 sig. fig. (ion), 0.001 pH |
| Accuracy | ±0.001 pH |
| Calibration Points | 2–6 (ion), 1–6 (pH) |
| Data Storage | 1000 entries with timestamp |
| GLP Compliance | Yes |
| Connectivity | RS232, optional USB |
| IP Rating | IP54 |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
Show next