Water Quality Analyzer
Filter
Showing 601–630 of 759 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Aquakem250 |
| Instrument Category | Laboratory Water Quality Analyzer |
| Detection Speed | 250 tests/hour |
| Sample Positions | 84 |
| Refrigerated Reagent Positions | 35 |
| Wavelength Range | 340–880 nm |
| Maximum Reagents per Test | 4 |
| Cadmium Reduction Module | Optional |
| Barcode Reader | Integrated |
| Sample/Reagent Dispensing | Fully Automated with Internal/External Tip Washing |
| Dilution Capability | Auto Primary & Secondary Dilution |
| Stirring | Independent Stir Bars with Dedicated Wash Station |
| Reagent Flexibility | User-Defined Methods and Custom Reagent Preparation Supported |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery |
| Instrument Category | Benchtop Automated Discrete Analyzer |
| Detection Methods | Photometric (275–880 nm, 12 fixed filters), Enzymatic, Electrochemical (ISE-based pH & Conductivity) |
| Throughput | Up to 200 tests/hour |
| Sample Capacity | 9-position rack × 2 = 18 racks (162 samples) |
| reagent capacity | 6 positions × 9 slots = 54 reagent positions |
| Cuvette Format | Disposable 10-cell flexible strip cuvettes |
| Incubation | Temperature-controlled incubation disc, programmable reaction time |
| Automation Features | Integrated barcode reader, auto-dilution (primary & secondary), on-board washing station, refrigerated sample/reagent carousel |
| Power/Water | <1.5 L/h water consumption |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | Finland |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Water Quality Analyzer |
| Model | Gallery Plus |
| Instrument Category | Benchtop Discrete Analyzer |
| Detection Principles | Photometric (Colorimetric), Enzymatic, and Electrochemical (ISE-based) |
| Sample Throughput | Up to 350 tests/hour |
| Wavelength Range | 275–880 nm (12 fixed-position interference filters) |
| Sample Capacity | 54 positions |
| Refrigerated Reagent Capacity | 42 positions |
| Reaction Vessel Format | 10-cell cuvette strips (up to 18 × 2 strips = 360 tests) |
| Incubation | Adjustable temperature incubation block (9 lanes × 10 positions = 90 test slots) |
| Electrochemical Module (ECM) | Integrated ISE-based pH and conductivity measurement |
| Sample Handling | Dual independent probes (sample + reagent), dedicated wash station, barcode reader |
| Dilution Capability | Onboard primary and secondary auto-dilution |
| Power & Utility | <2.5 L/h water consumption |
| Software Compliance | Audit-trail enabled, user-access control, electronic signature support per FDA 21 CFR Part 11 |
| Regulatory Alignment | Designed to support ISO/IEC 17025, ASTM D1293 (pH), ASTM D1125 (conductivity), EPA 365.3 (phosphate), USP <731>, and GLP/GMP workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | 5-Star |
| Price | Upon Request |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.001 |
| pH Calibration | 1–5 points, US/NIST, DIN, or user-defined buffers |
| ORP Range | ±1999.9 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| Ion Concentration Range | 0–19999 |
| Ion Resolution | 1–3 significant digits |
| Ion Units | M, mg/L, %, ppb, or unitless |
| Conductivity Range | 0.000–3000 mS/cm |
| Conductivity Resolution | down to 0.001 µS/cm (4-digit effective) |
| Conductivity Accuracy | ±0.5% ±1 digit or ±0.01 µS/cm (whichever is greater) |
| Resistivity Range | 0.0001–100 MΩ·cm |
| Salinity Range | 0.01–80.0 ppt NaCl |
| TDS Range | 0–19999 mg/L |
| Cell Constant Range | 0.001–199.9 cm⁻¹ |
| Reference Temperatures | 5, 10, 15, 20, or 25 °C |
| Electrode Compatibility | 2-electrode, 4-electrode, and planar conductivity cells |
| Conductivity Calibration | 1–5 points (manual) or 1–3 points (auto) |
| DO Range | 0.00–90.0 mg/L (0.0–600%) |
| DO Resolution | 0.01 mg/L / 0.1% |
| DO Accuracy | ±0.5% ±1 digit |
| Salinity Compensation | 0–45 ppt |
| Barometric Pressure Range | 450–850 mmHg |
| DO Calibration Methods | air-saturated water, water-saturated air, Winkler titration, zero-point |
| DO Sensor Type | polarographic membrane electrode |
| Temperature Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C (−5 to 99.9 °C), 1.0 °C (>99.9 °C) |
| Temperature Accuracy | ±0.1 °C |
| Temp Compensation | automatic or manual |
| Display | backlit LCD with icon-driven interface |
| Input Interfaces | pH–BNC, temperature–miniDIN, stirrer–phono jack (benchtop only) |
| Communication | bidirectional RS232, optional USB cable |
| Data Logging | 500 measurements |
| Calibration History | last 10 calibrations |
| Method Storage | 10 user-defined methods |
| Password Protection | 10 user accounts |
| Power | 4×AA batteries (portable) |
| Certifications | CE, CSA, UL, TÜV, FCC Class A |
| Operating Environment | 5–45 °C, 5–85% RH (non-condensing) |
| IP Rating | benchtop–IP54 |
| Dimensions (benchtop) | 9.4 × 17.0 × 22.4 cm (H×W×L) |
| (portable) | 4.8 × 9.7 × 21.3 cm (H×W×L) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable Benchtop/Field Water Quality Analyzer |
| Model | AQ4000 |
| Wavelengths | 420 nm, 520 nm, 580 nm, 610 nm |
| Wavelength Accuracy | ±2 nm |
| Photometric Linearity | ±0.002 A (0–1 A) |
| Photometric Repeatability | ±0.005 A (0–1 A) |
| Photometric Accuracy | ±0.005 A at 1.0 ABS |
| Stray Light | <1.0% at 400 nm |
| Light Source | LED |
| Detector | Photodiode |
| Bandwidth | 10 ± 2 nm |
| Operating Temperature | 0.0–50.0 °C |
| Relative Humidity | ≤90% at 50.0 °C |
| Ingress Protection | IP67 |
| Power Supply | 4 × AA alkaline batteries (2500 h) or lithium batteries (10,000 h) |
| Data Storage | 100 test records |
| Interface | RS232 |
| Sample Cell Compatibility | 13 mm, 16 mm, 24 mm cuvettes |
| Auto-ID™ Support | 13 mm barcoded vials only |
| Preloaded Methods | 190 |
| User-Defined Methods | 10 |
| Display | LCD with unit support (g/L, mg/L, ppm, %T, Abs) |
| Auto-Zero & Blank Correction | Yes |
| Standby Mode | Yes |
| Firmware Update Capability | Yes |
| Memory Retention on Power Loss | Yes |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AQ4001 |
| Instrument Type | Benchtop/Field-Deployable Water Quality Analyzer |
| Key Components | AQ4000 Multi-Parameter Colorimeter, pH Meter, Conductivity Meter, Turbidimeter, Reagent Kits, Portable Carry Case |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | CD650 |
| Instrument Category | Portable/Handheld Water Quality Analyzer |
| Key Parameters | Conductivity / TDS / Salinity / Resistivity / Dissolved Oxygen (DO) / Temperature |
| IP Rating | IP67 |
| Calibration | Auto 4-point (Conductivity), Manual 5-point (Conductivity), Single- or Multi-point DO |
| Electrode Support | Dual- or Quad-ring conductivity cells (cell constant 0.010–10.000 cm⁻¹) |
| DO Measurement Range | 0.00–90.00 mg/L (ppm) and 0.0–600.0% saturation |
| Conductivity Range | 0–500.0 mS/cm across five auto-ranging scales |
| Temperature Range (Instrument) | −10.0–110.0 °C |
| (DO Sensor) | 0–60.0 °C |
| Resolution | 0.01 μS/cm, 0.001 mS/cm, 0.01 mg/L, 0.1 °C |
| Accuracy | ±1% full scale + 1 LSD (Conductivity/TDS/Salinity/Resistivity), ±0.2 mg/L (DO), ±0.5 °C (Temperature) |
| Data Storage | 500 measurement sets |
| GLP Compliance | Yes |
| Communication | IrDA infrared, RS232C, optional PC connectivity via CyberLink software |
| Power | 4×AAA alkaline batteries (>200 h life) or 9 V regulated adapter |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Industrial-Grade Digital Water Quality Sensor System |
| Model | DataStick |
| Controller Compatibility | AV38 Universal Digital Controller (optional) |
| Max Sensor Nodes per Network | 247 |
| Communication Protocols | USB, RS-232, RS-485, Modbus RTU, Profibus DP, DeviceNet, Ethernet |
| Calibration | Factory-calibrated |
| Software | AquaComm™ Configuration & Diagnostics Suite |
| Compliance | Designed for industrial process monitoring in accordance with ISO 5667 (water sampling), ASTM D1129 (standard terminology relating to water), and compatible with GLP/GMP data integrity requirements (audit trail, user access control, electronic signature support in AquaComm v3.2+) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | CD650 |
| Instrument Category | Portable / Handheld Water Quality Analyzer |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Benchtop Analyzer |
| Model | PCD6500 |
| Measurement Parameters | pH / pH-FET / ORP / Ion Concentration / Conductivity / TDS / Salinity / Resistivity / Dissolved Oxygen (DO) / BOD / OUR / BOUR / Temperature (°C) |
| pH Range | −2.000–20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.1 / ±0.01 / ±0.002 + 1 LSD |
| Ion Range | 1×10⁻⁷–9.99×10¹⁰ ppm |
| Ion Resolution | 4-digit |
| Ion Accuracy | ±0.17 n% |
| Temperature Range | −5.0–105.0 °C (DO: −5.0–46.0 °C) |
| Temp Resolution | 0.1 °C |
| Temp Accuracy | ±0.2 °C |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±0.2 mV |
| Conductivity Ranges | 0–200 μS/cm, 200.0 μS/cm–2.000 mS/cm, 2.000–20.00 mS/cm, 20.00–500.0 mS/cm |
| Cond Resolution | 0.001/0.01/0.1 μS/cm or mS/cm |
| Cond Accuracy | ±0.5% FS + 1 LSD |
| TDS Ranges | 0–200.0 ppm, 200.0–2000 ppm, 2.000–20.00 ppt, 20.00–500.0 ppt |
| TDS Resolution | 0.001/0.01/0.1 ppm or ppt |
| TDS Accuracy | ±0.5% FS + 1 LSD (±1% FS + 1 LSD for select ranges) |
| Salinity Ranges | 0–0.094 ppt, 0.094–1.000 ppt, 1.0–11.50 ppt, 11.50–90.00 ppt |
| Salinity Resolution | 0.1 / 0.01 / 0.001 ppt |
| Salinity Accuracy | ±0.5% FS + 1 LSD |
| Resistivity Range | 0–100.0 MΩ |
| Resistivity Resolution | 0.1/0.01/0.001 kΩ or 0.1/0.01 mΩ |
| Resistivity Accuracy | ±0.5% FS + 1 LSD |
| DO Range | 0–60 mg/L |
| DO Resolution | 0.01 mg/L |
| DO Accuracy | ±0.1 mg/L + 1 digit |
| Calibration Points | up to 5-point for pH and ion |
| Temperature Compensation | Auto/manual for pH (−5–105 °C), conductivity (−5–100 °C), DO (−5–46 °C) |
| GLP Compliance | Yes |
| Data Storage | 1000 entries per user |
| Operating Temperature | 5–45 °C |
| Display | Windows CE–based color touchscreen (11.43 × 15.24 cm) |
| Interfaces | DC phono sockets, DIN, SD card reader, USB, RJ45, BNC, phono |
| Output Options | USB, IrDA, RS232C |
| Power Supply | 9 V regulated, 3.3 A (100–240 VAC, SMPS) |
| Dimensions (H×W×D) | 16.5 × 23.5 × 8.9 cm |
| Weight | 1100 g |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Portable/HANDHELD Water Quality Analyzer |
| Model | PD650 |
| Measurement Parameters | pH, ORP, Ion Concentration, Conductivity, TDS, Salinity, Resistivity, Dissolved Oxygen (DO), Temperature |
| IP Rating | IP67 |
| Accuracy (pH) | ±0.002 pH |
| Conductivity Accuracy | ±1% of full scale + 1 LSD |
| DO Range | 0.00–90.00 mg/L |
| Data Storage | 500 GLP-compliant entries |
| Auto-Range Conductivity | 5 ranges up to 500 mS/cm |
| Electrode Recognition | Automatic 2-/4-cell conductivity cell detection |
| Built-in Barometer | Yes |
| Wireless Capability | IrDA & RS232C |
| Battery Life | >200 hours |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Type | Laboratory Water Quality Analyzer |
| Model | Eutech PC2700 |
| Instrument Category | Benchtop Multiparameter Water Quality Meter |
| Compliance | GLP-compliant data logging |
| Connectivity | RS232 bidirectional interface |
| Electrode Interface | BNC, 8-pin DIN (2- or 4-ring), DC socket |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight | 0.65 kg (unit) |
| Operating Temperature | 0–50 °C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PCSTestr 35 |
| Instrument Category | Portable / Handheld Water Quality Analyzer |
| Key | pH Range 0.00–14.00, Resolution 0.01 pH, Accuracy ±0.01 pH |
| Calibration | Up to 5-point auto pH, 3-point auto/manual conductivity, 3-point manual TDS, 1-point auto salinity >1.00 ppt |
| Auto-Range Selection | Yes |
| Electrode Module | Integrated replaceable 5-in-1 sensor |
| Power | 4 × 1.5 V button cells (>150 h life) |
| Dimensions | 16.5 × 3.8 cm (unit), Weight: 90 g |
| Display | Dual-line LCD (2.1 × 2.7 cm) |
| Auto-Off | 8.5 min (configurable) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Country of Origin | Imported |
| Model | VERSA STAR |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, ISE (Ion Selective Electrode), Conductivity, Dissolved Oxygen (DO), Temperature |
| Compliance | GLP-Compliant Data Storage (2000 Records) |
| Connectivity | Dual USB + RS232 |
| Protection Rating | IP54 |
| Operating Modules | Up to 4 Simultaneous Modules |
| Stirrer Support | 2 Orion Star Stirrers (Hot-Swappable) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | 2117LL |
| Detection Limit | 1.5 ppb Cl⁻ |
| Measurement Principle | Potentiometric Chloride-Selective Electrode (CSE) |
| Calibration | Dynamic 1–3-point calibration with integrated pH adjustment |
| Compliance | Designed for continuous online monitoring in high-purity water systems |
| Application Environment | Semiconductor-grade UPW, boiler feedwater, RO permeate, condensate, seawater-cooled condenser leak detection |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific 3100 VA |
| Instrument Type | Online Water Quality Analyzer |
| Electrode Material | Mercury-Free Working Electrode |
| Measurement Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Compliance | Designed for EPA Method 300.1 / ISO 10566 / ASTM D7282-18 compatibility |
| Software | Embedded OS with bilingual (English/Chinese) interface |
| Maintenance | Low-consumption flow-injection system with self-diagnostic and auto-recovery functions |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific 3100 VA |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Bromate (BrO₃⁻) |
| Detection Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Electrode Material | Mercury-Free Solid-State Working Electrode |
| Sample Throughput | Up to 6 analyses per hour |
| Detection Limit | Sub-µg/L range (typical for bromate in drinking water) |
| Compliance | Designed for compliance with US EPA Method 300.1, ISO 10304-2, and WHO Guideline Values for Bromate |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Scientific 3510VA |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Bromate |
| Detection Principle | Chronopotentiometric Anodic Stripping |
| Electrode Material | Mercury-Free Solid-State Working Electrode |
| Sample Throughput | Up to 6 analyses/hour |
| Detection Limit | Sub-µg/L range (typical for bromate in drinking water) |
| Compliance | Designed for EPA Method 300.1 / ISO 10304-4 / ASTM D808–22 context |
| Software | Embedded Windows CE with GLP-compliant data logging |
| Power | 100–240 VAC, 50/60 Hz |
| Environmental Rating | IP54 enclosure |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific 3510VA |
| Instrument Type | Online Water Quality Analyzer |
| Analyte | Bromate |
| Detection Principle | Chronopotentiometric Anodic Stripping Voltammetry (ASV) |
| Electrode System | Mercury-free, non-plated solid working electrode |
| Sample Throughput | Up to 6 analyses per hour |
| Detection Limit | Sub-µg/L range (typical for bromate in drinking water matrices) |
| Compliance | Designed for EPA Method 300.1 and ISO 10304-3 compatibility |
| Software Interface | Embedded web-based UI with bilingual (English/Chinese) support |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | IP54 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific AquaClear |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Parameter | Turbidity |
| Compliance | Meets and exceeds USEPA Method 180.1 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Thermo Scientific AquaOZ |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Application | Real-time Dissolved Ozone Monitoring in Process Water Streams |
| Electrode Technology | Clark-type Amperometric Three-Electrode Sensor System |
| Controller Platform | AquaPro Multi-Channel Process Controller (up to 4 channels) |
| Data Logging Capacity | 1,000 data points with USB export |
| Firmware Update | USB-port field-upgradable |
| Language Support | 6 languages including English, Chinese, Spanish, French, German, and Portuguese |
| Membrane Assembly | Pre-filled, disposable membrane cap with electrolyte |
| Temperature Compensation | High-accuracy integrated Pt1000 RTD sensor |
| Housing Material Options | PVC, PVDF, 316L SS, and Hastelloy C-276 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | AquaPro |
| Instrument Category | Online Water Quality Analyzer |
| Measurement Flexibility | Configurable Input Channels for Any Parameter |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | AquaTurb / AquaSol |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Turbidity, Suspended Solids (SS) Concentration |
| Optical Method | ISO 7027-compliant Nephelometric & Backscatter Detection |
| Light Source | Infrared LED (850 nm) |
| Detection Angles | 90° and 180° |
| Output | Digital (RS-485, Modbus RTU), Optional 4–20 mA Analog |
| Temperature Compensation | Integrated Pt1000 sensor |
| Enclosure Rating | IP68 |
| Cleaning Option | Optional Automatic Wiper or Air-Pulse Self-Cleaning Module |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 510M-01 (Benchtop), 520M-01 (Portable) |
| Pricing | Upon Request |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A329 |
| Instrument Type | Portable Multiparameter Water Quality Analyzer |
| Compliance | GLP-Compliant Data Logging (5000 Entries) |
| Protection Rating | IP67 |
| Power | 4×AA Batteries or AC Adapter |
| Connectivity | USB & RS232 |
| Software Support | Orion™ Comli Software (FDA 21 CFR Part 11 Ready) |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | Thermo Scientific Water Quality Analyzer |
| Instrument Type | Laboratory Water Quality Analyzer |
| Price Range | USD 70,000 – 98,000 (based on configuration and regional import duties) |
| Key Compliance | ASTM D1293, ISO 7888, ISO 5667-3, USP <643>, EPA Methods 4500-OC, 4500-BOD, 4500-P, 4500-Cl⁻ |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | TP-1117 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH, ORP, Conductivity (4-electrode), Turbidity (fiber-optic), Dissolved Oxygen (fluorescence-based), Temperature, Chlorophyll-a, Oil-in-Water, Ammonia-Nitrogen (optional) |
| Output Interface | RS-485 with MODBUS RTU protocol |
| Sensor Architecture | Digital smart sensors with embedded calibration data |
| Probe Mounting | Waterproof quick-connect interface |
| Maintenance System | Integrated automatic wiper cleaning module |
| Channel Capacity | Up to 6 sensor inputs supporting simultaneous measurement of 7 parameters |
| Compliance | Designed for continuous unattended operation in compliance with ISO 5814, ISO 7888, ISO 7027, ASTM D3370, and EPA Method 180.1 |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer | TimePower Co., Ltd. |
| Model | TP/1117 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Phosphorus, Total Nitrogen, Conductivity, pH, ORP, Dissolved Oxygen (fluorescence-based), Turbidity (fiber-optic), Temperature, Optional: Chlorophyll-a, Oil-in-Water, Ammonia-Nitrogen |
| Sensor Interface | Digital RS485 with MODBUS RTU protocol |
| Max. Simultaneous Probes | 6 (up to 7 parameters) |
| Probe Mounting | Waterproof quick-connect interface |
| Maintenance | Integrated automatic cleaning system |
| Compliance | Designed for continuous operation in accordance with ISO 5667-22, ASTM D3370, and EPA Method 180.1 principles for online water quality monitoring |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TP1117 |
| Instrument Type | Laboratory & Online Water Quality Analyzer |
| Measurable Parameters | Dissolved Oxygen (DO), Electrical Conductivity (EC), Turbidity, pH, Oxidation-Reduction Potential (ORP), Chlorophyll-a, Oil-in-Water, Ammonia-Nitrogen (NH₃-N) |
| Sensor Interface | RS485 with MODBUS RTU protocol |
| Probe Configuration | Up to 6 digital sensor inputs (simultaneous 7-parameter measurement) |
| Calibration Data Storage | Embedded in each smart sensor |
| Environmental Rating | IP68 submersible housing |
| Cleaning System | Integrated automatic mechanical wiper and air-pulse anti-fouling module |
| Compliance | Designed for ASTM D3370, ISO 5814 (DO), ISO 7888 (EC), ISO 7027 (Turbidity), USP <643>, EPA Method 180.1 (pH), GLP-compliant data logging architecture |
| Brand | TimePower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TP 1117 |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Measurable Parameters | pH, Conductivity, Turbidity, Dissolved Oxygen (DO), Temperature, ORP, Chlorophyll-a, Oil-in-Water, Ammonia-Nitrogen |
| Sensor Interface | RS485 with MODBUS RTU protocol |
| Probe Configuration | Up to 6 digital sensor inputs (simultaneous 7-parameter measurement) |
| Calibration Storage | Embedded in each smart sensor |
| Enclosure Rating | IP68 submersible housing |
| Auto-Cleaning System | Integrated mechanical wiper and optional ultrasonic cleaning module |
| Compliance | Designed to support ISO 5814, ASTM D888, ISO 7027, ISO 7888, USP <643>, GLP-compliant data logging |
