Water Quality Analyzer
Filter
Showing 631–660 of 734 results
| Origin | Australia |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UAC Series |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH (single/dual), CO₂, Alkalinity, ORP, Free Available Chlorine (FAC), Conductivity / TDS, Temperature |
| Display | 7-inch Color Touchscreen |
| Input/Output Flexibility | Universal Sensor Inputs, Relay Outputs (Configurable), Timer Functions, Web-Based Remote Access |
| Compliance Support | Designed for GLP-aligned operational logging and configurable audit trails per ISO/IEC 17025-informed practices |
| Software Capability | Trend Logging, Onboard Calibration History, Firmware Upgradability |
| Brand | Wagtech |
|---|---|
| Origin | United Kingdom |
| Model | Potalab |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Capabilities | Microbiological Testing, Physicochemical Parameter Analysis |
| Key Components | Portable Incubator (dual-zone, 20–50 °C), Digital Arsenic Analyzer (2–100 µg/L, arsenical spot method), 7100 Multi-parameter Photometer (≥100 pre-programmed calibration curves, IP67 rated), Portable Turbidimeter (ISO 7027 compliant, 0.01–1000 NTU), pH/Conductivity/TDS Meter (IP67, auto-temp compensation) |
| Brand | Water Doctor |
|---|---|
| Origin | Hunan, China |
| Model | Dr-W112 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Principle | Spectrophotometric (4-AAP Method per HJ 503-2009 / ISO 6439) |
| Primary Target Analyte | Volatile Phenols |
| Measured Parameters | Turbidity (0–20 NTU / 0–200 NTU / 0–1000 NTU), Color, Free Chlorine, Chlorine Dioxide, Total Hardness, Permanganate Index (COD<sub>Mn</sub>), Ammonia Nitrogen, Ozone, Urea, Iron, Manganese |
| Wavelength Range | 330–900 nm |
| Wavelength Accuracy | ±5 nm |
| Photometric Resolution | 0.001 Abs |
| Optical Stability | ≤±0.005 Abs/20 min |
| Repeatability | ≤±2% |
| Accuracy | ≤±5% |
| Light Source | Imported Long-Life Cold LED (≥100,000 h) |
| Sample Cell | 16 mm and 25 mm round cuvettes |
| Display | 5-inch HD color TFT capacitive touchscreen |
| Language Support | English & Chinese |
| Power Supply | Rechargeable Li-ion battery + AC adapter (dual-mode operation) |
| Data Storage | Up to 1,000,000 measurement records |
| Connectivity | USB Type-C (charging + data transfer) |
| Printing | Built-in thermal printer |
| Calibration Modes | Blank, Factor, and Multi-point Curve Calibration |
| Interference Compensation | Integrated chromaticity & optical attenuation correction algorithm |
| Housing Material | Corrosion-resistant ABS with IP67-rated enclosure |
| Compliance | Designed in accordance with HJ 503-2009 (China), ISO 6439:1984, and ASTM D1209/D5810 for phenolic compounds |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | WaterWhisperer WW-COD |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Online COD Analyzer |
| Measured Parameter | Chemical Oxygen Demand (COD) |
| Detection Principle | Spectrophotometric Measurement after Acidic Potassium Permanganate Digestion |
| Communication Interface | RS232, RS485, MODBUS RTU |
| Data Storage | 2000 records |
| Power Recovery | Auto-restart after power outage |
| Operating Environment | 5–40 °C, ≤85% RH non-condensing |
| Installation Options | Wall-mount, benchtop |
| Compliance | Designed to support ISO 15705:2002 (COD by permanganate method), ASTM D1253, and GLP-aligned data integrity practices |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WetChem |
| Price Range | USD 98,000 – 140,000 |
| Instrument Type | Online Water Quality Analyzer |
| Analyte Categories | Inorganic ions (e.g., sulfide, sulfate, ammonia-nitrogen, nitrate, nitrite, phosphate, silicate, chloride, fluoride, alkalinity, Cr(VI)) |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | WetChem300 |
| Price Range | USD 70,000–98,000 (FOB) |
| Instrument Category | Online Water Quality Analyzer |
| Measurable Parameters | Ammonia-N, Nitrate, Nitrite, Orthophosphate, Silicate, Sulfate, Sulfide, Alkalinity, Hexavalent Chromium, Fluoride, Iron, Copper, Zinc, Cadmium, Boron, Hydrazine, Chloride |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WQM |
| Pricing | Available Upon Request |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | FDO |
| Measurement Principle | Fluorescence-based (dynamic quenching) |
| Detection Parameter | Dissolved Oxygen (DO) |
| Instrument Type | Online Water Quality Analyzer |
| Compliance | Designed for continuous monitoring in wastewater treatment and environmental applications |
| Calibration | Factory-calibrated smart sensor with embedded calibration chip (IQMC) |
| Optical System | Dual-path EPRS (Equal Path Reference System) |
| Light Source | Green LED (GLT technology) |
| Sensor Geometry | 45° beveled tip for bubble rejection |
| Operating Environment | Aqueous media, activated sludge, surface water, and effluent streams |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | inoLab® Multi 9310 |
| Measurement Parameters | pH, ORP, Conductivity, Dissolved Oxygen (optical fluorescence), Temperature |
| Sensor Interface | IDS (Intelligent Digital Sensors) |
| Compliance | GLP, AQA |
| Data Storage | 5,000 readings with timestamp, user ID, and sensor serial number |
| Connectivity | Mini USB-B |
| Power Supply | AC adapter or 4 × AA batteries |
| Calibration Memory | Up to 10 calibrations with scheduling (1–999 days) |
| Temperature Compensation | Automatic for all parameters except ORP |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | inoLab Multi 9430 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurable Parameters | pH, mV (ORP), Conductivity, Resistivity, Salinity, Dissolved Oxygen (DO), Turbidity, Ion-Selective Electrode (ISE) Concentration |
| Connectivity | Digital Smart Probe Interface (No Cable Required) |
| Display | Backlit Graphic LCD with Antimicrobial Keypad |
| Probe Management | QSC (Quality Sensor Control) & CMC (Continuous Measurement Control) |
| Data Storage | Up to 10,000 measurement sets |
| Compliance | Designed for ISO/IEC 17025-compliant labs |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 9430 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurement Principle | Electrochemical (pH, ORP, Conductivity, Optical Dissolved Oxygen) |
| Measured Parameters | pH, ORP, Conductivity, Dissolved Oxygen (optical), Temperature |
| Sensor Interface | Digital IDS (Intelligent Digital Sensors) |
| Channels | 3 independent digital sensor inputs |
| Data Storage | 10,000 measurement sets |
| Compliance | GLP/AQA-ready, FDA 21 CFR Part 11–compatible data handling |
| Connectivity | USB-A (host), Mini-USB-B (device), optional external printer support |
| Display | Backlit color graphic LCD |
| Keyboard | Antimicrobial-coated membrane keypad |
| Power Supply | Universal AC adapter |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | IQ Sensor Net |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | pH, ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity, Total Suspended Solids (TSS), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Salinity, Ammonium-N (NH₄⁺-N), Nitrate-N (NO₃⁻-N), Nitrite-N (NO₂⁻-N), Total Organic Carbon (TOC), Spectral Absorption Coefficient (SAC), Phosphate (PO₄³⁻) |
| Enclosure Rating | Transmitter IP66 / Sensors IP68 |
| Communication | RS-485/232, MODBUS RTU, PROFIBUS DP |
| Analog Outputs | ≥6 × 4–20 mA |
| Relay Outputs | ≥6 |
| Digital Signal Transmission Distance | Up to 1000 m over 2-wire shielded cable |
| Power Supply | 24 VDC via signal cable |
| Sensor Auto-Recognition | Yes |
| Max. Connected Sensors | 20 |
| Cleaning Technology | Integrated ultrasonic cleaning (turbidity/TSS sensors) |
| Measurement Principle | Potentiometric (pH/ORP), Optical luminescence (DO), 4-electrode conductivity, 90° scattered light turbidimetry (FNU), UV-VIS absorbance (COD/SAC/NO₃⁻/NH₄⁺/PO₄³⁻), respirometric (BOD), catalytic oxidation (TOC) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | MIQ/TC 2020 3G |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | pH/ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity, Sludge Concentration, COD/BOD/TOC/DOC/SAC/UVT, Ammonia-N, Nitrate-N, Nitrite-N, Sludge Interface, Phosphate |
| Max Sensor Channels | 20 |
| Analog Outputs & Relays | up to 48 |
| Max Total Cable Length | 1000 m |
| Data Storage Capacity | 526,600 records |
| Enclosure Rating | IP66 |
| Communication Protocols | PROFIBUS-DP, MODBUS RTU, Ethernet/IP, MODBUS TCP, PROFINET |
| USB Interface | Data export & password-protected system unlock via USB key |
| Optional Remote Connectivity | GSM/Analog modem, Wireless module |
| Calibration Support | IQ-LabLink intelligent calibration system |
| Surge Protection | Integrated lightning protection |
| Redundancy | Standby controller functionality with automatic failover to MIQ/CM3 display unit |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | MPP 910/930 |
| Detection Principle | Electrochemical & Piezoresistive Pressure Transduction |
| Measured Parameter | Depth (Hydrostatic Pressure) |
| Depth Range | 0.50–100 m |
| Resolution | 0.05 m |
| Accuracy | ±0.25 m |
| Pressure Rating | 10 bar |
| Housing Material | Titanium Alloy (MPP 930), POM + Stainless Steel (MPP 910) |
| IP Rating | IP68 |
| Temperature Compensation | Integrated RTD for density- and air pressure-corrected depth calculation |
| Electrode Channels | 1 (MPP 910) or 3 (MPP 930) |
| Compatible Instrument Platform | WTW Multi 3430 with IDS Digital Interface |
| Cable Length Options | 1.5–100 m (field-replaceable) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | MPP IDS |
| Instrument Type | Portable Multi-Parameter Water Quality Sensor |
| Measurable Parameters | pH / ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity |
| Probe Interface | Digital IDS (Intelligent Digital Sensor) interface supporting up to three simultaneous IDS-compatible probes |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3320 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurement Principle | Electrochemical Sensing |
| Measurable Parameters | pH, ORP, Dissolved Oxygen (DO), Conductivity, Temperature |
| Compliance | GLP-compliant data logging |
| Memory Capacity | 5000 GLP-formatted records |
| Display | Backlit graphical LCD |
| Input Channels | Dual analog inputs (DIN 8-pin) |
| Protection Rating | IP67 |
| Power Supply | 4 × 1.5 V AA alkaline batteries (up to 1000 h operation) |
| Dimensions | 180 × 80 × 55 mm (H × L × W) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3420 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurement Principle | Electrochemical (pH, ORP, Conductivity), Optical (Luminescence-based Dissolved Oxygen), Nephelometric (Turbidity) |
| Measured Parameters | pH, Dissolved Oxygen (DO), Oxidation-Reduction Potential (ORP), Electrical Conductivity, Turbidity |
| Display | High-resolution color TFT screen |
| Data Storage | Up to 10,000 measurement sets with automatic logging |
| Connectivity | Dual USB (standard + mini-USB), U-disk export, PC synchronization |
| Enclosure Rating | IP67 |
| Power Supply | Rechargeable 4×1.2 V NiMH battery (up to 100 h operation) |
| Sensor Interface | Intelligent Digital Sensor (IDS) technology with auto-recognition and embedded calibration memory |
| Compliance | GLP/AQA-compliant data management, supports FDA 21 CFR Part 11 audit trail requirements via software extension |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3510 2FD351 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical Method |
| Measured Parameters | pH, ORP, Dissolved Oxygen (DO), Conductivity, Turbidity |
| Repeatability | <1% |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3510 2FD353 |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Principle | Electrochemical Method |
| Measured Parameters | Dissolved Oxygen, pH, ORP, Conductivity, Turbidity |
| Repeatability | <1% |
| Display | LCD with Graphical Interface |
| Data Storage | Up to 10,000 Sets (Manual & Time-Controlled) |
| Connectivity | Micro-USB-B, Optional Wireless Module |
| Protection Rating | IP67 |
| Power Supply | 4 × AA Alkaline or 4 × 1.2 V NiMH Rechargeable Batteries / USB Bus Power |
| Probe Interface | Digital IDS (Intelligent Digital Sensor) Technology |
| Auto-Sensor Recognition | Yes |
| Calibration Data Storage | Embedded in IDS Probes |
| Electrical Isolation | Yes (Signal Integrity Preservation) |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3510 2FD354 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical Sensing |
| Measured Parameters | Dissolved Oxygen (DO), pH, ORP, Conductivity, Turbidity |
| Display | LCD Graphical Screen |
| Data Storage | Up to 10,000 datasets (manual + automatic) |
| Interface | Micro-USB-B |
| Power Supply | 4×1.5 V AA alkaline or 4×1.2 V NiMH rechargeable batteries |
| Protection Rating | IP67 |
| Probe Recognition | Automatic digital IDS probe identification |
| Electrical Isolation | Yes (prevents signal interference) |
| Compliance | CE marked |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3510 IDS |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical (for DO, pH, ORP, conductivity) & Optical (for turbidity) |
| Measured Parameters | Dissolved Oxygen (DO), pH, ORP, Conductivity, Turbidity |
| Repeatability | <1% |
| Display | Graphical LCD |
| Data Storage | Up to 10,000 datasets (manual + auto) |
| Interface | Micro-USB-B |
| Protection Rating | IP67 |
| Power Supply | 4 × AA alkaline or 4 × 1.2 V NiMH rechargeable batteries (USB charging supported) |
| Probe Communication | Digital IDS (Intelligent Digital Sensor) interface with automatic recognition and embedded calibration memory |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3620 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | pH, ORP, Dissolved Oxygen (DO), Oxygen Saturation, Partial Pressure of Oxygen (pO₂), Conductivity, Resistivity, Salinity, TDS, Turbidity |
| Measurement Range (Dissolved Oxygen) | 0–50 mg/L |
| Display | Graphical LCD |
| Data Storage Capacity | Up to 10,000 datasets (manual + automatic) |
| Protection Rating | IP67 |
| Power Supply | 4×1.5 V AA alkaline or 4×1.2 V NiMH rechargeable batteries, or USB-powered operation |
| Interface | Micro-USB-B, USB-A (for memory card and printer connectivity) |
| Probe Communication | Digital IDS (Intelligent Digital Sensor) interface with wireless-capable probe pairing |
| Sensor Compatibility | MPP 910 IDS (single-parameter), MPP 930 IDS (triple-parameter, including depth measurement up to 100 m with pressure & density compensation for seawater) |
| Depth Resolution | 0.05 m |
| Depth Accuracy | ±0.25 m |
| Housing Material | POM polymer and stainless steel |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3620 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical Sensing (pH, ORP, Conductivity, DO) & Nephelometric Turbidity Measurement |
| Measured Parameters | pH, ORP, Dissolved Oxygen (DO), Conductivity, Turbidity (NTU/FNU) |
| Display | Color Graphic LCD |
| Data Storage | Up to 10,000 datasets (manual + auto logging) |
| Measurement Channels | 2 simultaneous digital IDS probe inputs |
| Communication | USB-B, optional wireless module (Bluetooth® Class 1, up to 10 m range) |
| Protection Rating | IP67 |
| Power Supply | 4 × AA alkaline or 4 × NiMH rechargeable batteries (1.2 V), or USB bus power |
| Compliance | CE-marked, designed per IEC 61000-6-2/-4 for electromagnetic immunity in field environments |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 3630 IDS |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Detection Principle | Electrochemical Sensing (pH, ORP, Conductivity, DO) & Optical Turbidity Measurement (Nephelometry) |
| Measured Parameters | pH, ORP, Dissolved Oxygen (DO), Conductivity, Turbidity |
| Display | Color LCD with Graphical Interface |
| Data Storage | Up to 10,000 datasets (manual & time-controlled logging) |
| Communication | USB-B port, optional wireless module (Bluetooth-compatible IDS interface) |
| Protection Rating | IP67 |
| Power Supply | 4 × AA alkaline / 4 × NiMH rechargeable / USB bus power |
| Measurement Channels | 3 independent digital IDS channels |
| Compliance | CE-marked, designed for GLP-compliant field and laboratory use |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 9310 IDS |
| Instrument Type | Laboratory Water Quality Analyzer |
| Detection Principle | Electrochemical Sensing (pH, ORP, Conductivity, Dissolved Oxygen) |
| Measurable Parameters | pH, ORP, Dissolved Oxygen (DO), Oxygen Saturation (%), Partial Pressure of Oxygen (pO₂), Conductivity, Resistivity, Salinity, TDS, Turbidity (with optional turbidity sensor), Ion Concentration (with ISE adapter) |
| Display | Backlit Graphical LCD |
| Data Storage | Up to 10,000 datasets (manual + automatic logging) |
| Connectivity | Micro-USB-B, USB-A (for printer/storage), Optional Wireless Module (Bluetooth® Class 2) |
| Probe Interface | Digital IDS (Intelligent Digital Sensor) protocol with auto-recognition |
| Smart Diagnostics | QSC (Quality Sensor Check) and CMC (Continuous Measurement Control) |
| Power Supply | 4 × AA alkaline batteries or USB-B powered |
| Protection Rating | IP43 |
| Compliance | Designed for GLP-compliant workflows |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 9620 IDS |
| Instrument Type | Benchtop Laboratory Multi-Parameter Analyzer |
| Measurement Principle | Electrochemical (pH, ORP, Conductivity, DO) + Optical (Turbidity) |
| Parameters | pH, ORP, Dissolved Oxygen (DO), Oxygen Saturation (%), Partial Pressure of Oxygen (pO₂), Conductivity, Resistivity, Salinity, TDS, Turbidity |
| Display | Graphical LCD with Backlight |
| Data Storage | 500 Manual / 10,000 Automatic Records |
| Measurement Channels | 2 Simultaneous |
| Probe Interface | Digital IDS (Intelligent Digital Sensor) Protocol |
| Connectivity | Micro-USB-B, USB-A (for USB flash drive or thermal printer), Optional Wireless Module (via Bluetooth-enabled IDS probes) |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Power Supply | 4 × AA batteries (1.5 V) or USB-B bus power |
| Protection Class | IP43 |
| QSC (Quality Sensor Control) & CMC (Calibration Management Center) | Yes |
| Software Export Format | CSV and Excel-compatible (.xlsx) via USB storage |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Multi 9630 |
| Instrument Type | Portable/Laboratory Multiparameter Water Quality Analyzer |
| Detection Principle | Electrochemical (pH, ORP, Conductivity, DO) + Optical (Turbidity) |
| Measured Parameters | pH, ORP, Dissolved Oxygen (DO), Conductivity, Turbidity |
| Display | Backlit Graphic LCD |
| Data Storage | 10,000 automatic / 500 manual entries |
| Measurement Channels | 3 simultaneous IDS probe inputs |
| Connectivity | USB-B, USB-A (for printer/storage), optional wireless module |
| Compliance | QSC (Quality Sensor Control), CMC (Continuous Measurement Control), IP43 enclosure |
| Power | 4 × 1.5 V AA batteries or USB-B powered |
| Probe Interface | Digital IDS (Intelligent Digital Sensor) with auto-recognition and embedded calibration memory |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Multi350i |
| Pricing | Available Upon Request |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Pro40 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurement Principle | Electrochemical Sensing (pH, ORP, Conductivity, Dissolved Oxygen) + Optical Turbidimetry |
| Measurable Parameters | pH, ORP, mV, Conductivity, Dissolved Oxygen (DO), Turbidity, ISE (upcoming) |
| Channels | 4 Electrically Isolated Input Channels |
| Display | 7-inch High-Brightness Capacitive Touchscreen with Sanitary Glass Overlay |
| Sensor Interface | IDS Digital Smart Sensor Protocol |
| Wireless Capability | Compatible with IDS Wireless Module (optional) |
| Compliance | Designed for GxP environments |
| Data Export Formats | PDF/A, JSON, CSV |
| Operating Modes | Standard Mode & GxP Mode (with configurable trial period) |
| Environmental Rating | IP65-rated enclosure (front panel) |
| Certifications | CE, RoHS, ISO/IEC 17025–supportive calibration traceability |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Model | Pro20 |
| Instrument Type | Laboratory Water Quality Analyzer |
| Measurement Principle | Electrochemical Methods |
| Measurable Parameters | pH, ORP, Conductivity, Dissolved Oxygen (DO), Turbidity, mV |
| Channel Configuration | Dual electrically isolated measurement channels |
| Display | 7-inch high-brightness color touchscreen with chemically strengthened sanitary glass |
| Sensor Interface | IDS (Intelligent Digital Sensors) compatible, supports optional wireless module |
| Compliance | Designed for GxP environments |
| Data Export Formats | PDF/A, JSON, CSV |
| Software Features | QSC (Quality Sensor Check), AutoRead, customizable calibration buffers & methods, LIMS integration support |
| Operating Environment | Suitable for fume hoods, biosafety cabinets, and cleanroom-grade labs |
| Glove-Compatible Touchscreen | Yes, resistant to ethanol and common disinfectants |
| ISE Compatibility | Planned future expansion (not yet available) |