Water Vapor Transmission Rate Tester
Filter
Showing 31–60 of 131 results
| Brand | GBPI |
|---|---|
| Model | W403-G |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 1–9,999 |
| Testing Range | 0.001–100 g/m²·24h (films & sheets) |
| Test Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 0%RH (dry), 30–90%RH, 100%RH |
| Humidity Stability | ±1%RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Specimen Thickness | ≤2 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tube |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W403A |
| Moisture Permeation Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) (for films & sheets) |
| Temperature Control Range | 15–45°C (optional 5–55°C) |
| Temperature Accuracy | ±0.1°C |
| Humidity Control Range | 0% RH, 30–90% RH, 100% RH |
| Humidity Accuracy | ±1% RH |
| Specimen Quantity | 3 |
| Sensors | 3 infrared moisture sensors |
| Specimen Size | Φ100 mm (test area: 50.24 cm²) |
| Max. Specimen Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa pressure |
| Gas Flow Rate | 0–100 mL/min |
| Interface | 1/8″ stainless-steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power | 220 V, 50 Hz (110 V optional) |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | W403B |
| Measurement Principle | Infrared Sensor Method |
| Standards Compliance | ISO 15106-2, ASTM F1249, TAPPI T557, JIS K7129, GB/T 26253 |
| WVTR Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) (for films & sheets) |
| Temperature Control Range | 15–45 °C (optional 5–55 °C) |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0 %RH, 30–90 %RH, 100 %RH |
| Humidity Accuracy | ±1 %RH |
| Sample Capacity | 3 test positions |
| Sensor Count | 3 infrared hygrometric sensors |
| Specimen Size | Ø100 mm (effective area: 50.24 cm²) |
| Max. Sample Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity nitrogen (≥99.999 %), inlet pressure ≥0.1 MPa |
| Gas Flow Rate | 0–100 mL/min |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power Supply | 220 V, 50 Hz (110 V optional) |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | W405 |
| Test Range | 0.0005–500 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH, 100 %RH |
| RH Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999 % N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Interface | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | W405 |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Detection of Moisture |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| RH Accuracy | ±1 %RH |
| Permeation Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity N₂ (99.999%, user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–100 mL/min |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Model | W405-A |
| Measurement Principle | Infrared Detection of Water Vapor |
| Test Range | 0.005–500 g/(m²·24h) |
| Accuracy | ±0.001 g/(m²·24h) |
| Temperature Control | 15–45°C (optional up to 60°C), ±0.1°C |
| Humidity Control | 0%, 30–90%, or 100% RH, ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Sample Size | Ø100 mm, ≤3 mm thickness |
| Sample Capacity | 1–3 specimens per run |
| Carrier Gas | High-purity nitrogen (99.999%), 5–120 mL/min, ≥0.1 MPa |
| Power | AC 220 V, 50 Hz, 1000 W |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405-LP |
| Price Range | USD 42,000 – 70,000 |
| Test Range | 0.005–500 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 0% RH (dry N₂), 30–90% RH, 100% RH |
| Humidity Stability | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixture) |
| Specimen Size | Ø100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Interface | 1/8″ metal tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405A |
| Test Range | 0.0005–500 g/(m²·24h) |
| Measurement Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH (and 100 %RH) |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (reducible to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405B |
| Test Range | 0.0005–500 g/(m²·24h) (films & sheets) |
| Measurement Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH (and 100 %RH) |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999 % N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | W405C |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Standard Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Carrier Gas | High-purity N₂ (≥99.999%, 0.1–0.6 MPa, 5–100 mL/min) |
| Power Supply | AC 220 V, 50 Hz, 750 W |
| Sample Capacity | 3 positions |
| Data Integrity | Audit trail, electronic signatures, 21 CFR Part 11–compliant software architecture |
| Key | Brand: GBPI |
|---|---|
| Model | W405D |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Test Range | 0.0005–500 g/(m²·24h) |
| Accuracy | ±0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Range | 30–90 %RH (including 100 %RH) |
| RH Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂, 0.1 MPa min. pressure, 5–120 mL/min flow |
| Interface | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405G |
| Price Range | USD 14,000–28,000 |
| Test Range | 0.005–500 g/(m²·24h) |
| Measurement Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 30–90% RH (up to 100% RH optional) |
| Humidity Stability | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | Ultra-high-purity N₂ (≥99.999%), inlet pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Fitting | 1/8″ stainless steel compression fitting |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | W405I |
| Pricing | Upon Request |
| Test Range | 0.005–500 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C |
| Humidity Control | 0% RH (dry), 30–90% RH, 100% RH, ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V / 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | W405WE |
| Price Range | USD 42,000 – 70,000 |
| Test Range | 0.005–500 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 0% RH (dry N₂), 30–90% RH, 100% RH |
| Humidity Stability | ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixture) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent test chambers |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Interface | 1/8″ stainless steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V, 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W413 2.0 |
| Price | ¥368,000 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | W413 2.0M |
| Price Range | USD 42,000 – 70,000 |
| Measurement Principle | Infrared Detection of Water Vapor |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| RH Accuracy | ±1 %RH |
| Permeation Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 positions |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0 |
| Quotation | Upon Request |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0B |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GBPI W413 2.0C |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | W413 2.0K |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| N₂ Pressure | ≥0.1 MPa |
| N₂ Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | W413 2.0L |
| Price Range | USD 42,000–70,000 |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0%RH (dry), 30–90%RH, 100%RH |
| RH Accuracy | ±1%RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per run |
| Carrier Gas | ≥99.999% N₂ |
| Gas Pressure | ≥0.1 MPa |
| Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | W413 2.0R |
| Price Range | USD 42,000–70,000 |
| Measurement Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | 3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | ≥99.999% N₂, 5–100 mL/min, ≥0.1 MPa pressure |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | W413 2.0S |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0% (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | Ultra-high-purity N₂ (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W413 2.0U |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, YBB 00092003-2015, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 positions |
| Carrier Gas | ≥99.999% N₂ |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W413D |
| Pricing | Upon Request |
| Test Range | 0.002–1000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control | 15–45°C (optional up to 60°C), ±0.1°C |
| Humidity Control | 0%, 30–90%, or 100% RH, ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Sample Diameter | Φ100 mm |
| Max Sample Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Power Supply | AC 220 V, 50 Hz (110 V optional) |
| Dimensions | 610 × 550 × 300 mm |
| Weight | 57.1 kg |
| Power Consumption | 1000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W413Q |
| Test Range | 0.002–1000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow 5–120 mL/min |
| Interface | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W413T |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 26253-2010, YBB 00092003-2015, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Carrier Gas Pressure | ≥0.1 MPa |
| Carrier Gas Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Input Power | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W413U |
| Price Range | USD 42,000–70,000 |
| Test Range | 0.002–1000 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 30–90% RH |
| Humidity Control Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Carrier Gas Pressure | ≥0.1 MPa |
| Carrier Gas Flow Rate | 5–120 mL/min |
| Gas Inlet Port | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W413Z |
| Price Range | USD 42,000 – 70,000 |
| Test Range | 0.002–1000 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Control Accuracy | ±0.1°C |
| Humidity Control Range | 30–90% RH |
| Humidity Control Accuracy | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Voltage | AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W501 |
| Pricing | Upon Request |
| Measurement Principle | Gravimetric (Weight Gain) Method |
| Standards Compliance | GB/T 1037–1988, GB/T 16928–1997, ASTM E96/E96M–2016, ASTM D1653–2013, TAPPI T464, ISO 2528–1995, DIN 53122–1, JIS Z0208–1976, YBB00092003–2015 |
| Test Range | 0.1–10,000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Weight Resolution | 0.1 mg |
| Temperature Control Range | 15–55 °C |
| Temp Stability | ±0.1 °C |
| Humidity Control Range | 30–90% RH and 100% RH |
| RH Accuracy | ±1% RH |
| Test Area | 86.54 cm² |
| Specimen Diameter | Φ125 mm |
| Max Thickness | ≤5 mm |
| Purge Air Velocity | 0.5–2.5 m/s |
| Interface | Φ4 mm polyurethane tubing |
| Air Supply Pressure | ≥0.2 MPa |
| Dimensions | 680 × 550 × 375 mm |
| Weight | 50 kg |
| Power | 500 W |
| Voltage/Frequency | AC 220 V, 50 Hz |