Water Vapor Transmission Rate Tester
Filter
Showing 91–120 of 131 results
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Model | C360M |
| Test Principle | Gravimetric (ASTM E96 / GB 1037 compliant) |
| Test Modes | Gain-Weight & Loss-Weight |
| Test Stations | 6 independent chambers |
| Temperature Range | 15–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max Thickness | ≤3 mm |
| Effective Test Area | 33 cm² |
| WVTR Range (Loss-Weight) | up to 10,000/n g/(m²·day) (n = 1–6) |
| WVTR Range (Gain-Weight) | up to 1200 g/(m²·day) per station |
| Carrier Gas | Compressed air (≥0.6 MPa) |
| Drying System | Core-free, 20,000-hour service life |
| Humidification | Fog-free internal humidifier |
| Control | 12″ Windows 10 touchscreen interface |
| Data Management | DataShield™ audit-trail-enabled software |
| Optional Compliance | 21 CFR Part 11, GMP computer system validation |
| Brand | Labthink |
|---|---|
| Model | C360M |
| Principle | Gravimetric (Weight Gain/Loss Method) |
| Standards | ASTM E96, GB 1037, GB/T 16928, ISO 2528, YBB00092003-2015 |
| Test Stations | 6 |
| Temperature Range | 15–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max Thickness | ≤3 mm |
| Test Area | 33 cm² |
| WVTR Range (Loss Mode) | up to 10,000/n g/(m²·day) (n = 1–6) |
| WVTR Range (Gain Mode) | up to 1200 g/(m²·day) per station |
| Carrier Gas | Compressed Air (≥0.6 MPa) |
| Drying System | Coreless Long-Life Desiccant Module (20,000 h operational life) |
| Humidification | Internal Fog-Free Steam Generator |
| Data Compliance | Optional 21 CFR Part 11 & GMP Audit Trail Support |
| OS | Windows 10 Embedded on 12″ Touchscreen Tablet |
| Software | DataShield™ Secure Data Management Platform |
| Brand | Labthink |
|---|---|
| Model | C390H |
| Measurement Principle | Infrared Absorption Spectroscopy (ASTM F1249, ISO 15106-2) |
| Test Chambers | 3 independent, integrated cavities |
| Standard Test Area | 50 cm² |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| WVTR Range | 0.005–40 g/(m²·day) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% (whichever is greater) |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH |
| Carrier Gas | Ultra-high-purity N₂ (≥99.999%), inlet pressure ≥0.28 MPa |
| Gas Interface | 1/8″ stainless steel tubing |
| Packaging Test Capability | Up to 3 L containers (optional) |
| Compliance Options | FDA 21 CFR Part 11, GMP-compliant computer system, DataShield™ audit-trail data management (optional) |
| Brand | Labthink |
|---|---|
| Model | C390H |
| Measurement Principle | Infrared Detection of Water Vapor |
| Standards Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Test Range | 0.005–40 g/(m²·day) (film) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% (whichever is greater) |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90% RH (±1% RH), up to 100% RH |
| Test Chambers | 3 independent, integrated cavities |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Container Capacity | Up to 3 L |
| Carrier Gas | Ultra-high-purity N₂ (≥99.999%), inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail compliant software |
| Regulatory Options | CFR 21 Part 11, GMP-compliant computer system, GLP/GMP validation support |
| Brand | Labthink |
|---|---|
| Model | PERME W3/031 |
| Principle | Gravimetric Cup Method |
| Standards | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Test Range | 0.1–10,000 g/m²·24h |
| Resolution | 0.0001 g |
| Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Sample Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Cup Quantity | 3 independent cups |
| Air Flow Velocity | 0.5–2.5 m/s |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | PERME W3/031 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 14,000–57,000 |
| Test Principle | Gravimetric Cup Method (ASTM E96, GB/T 1037) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Measurement Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm PU tubing |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Net Weight | 83 kg |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Brand | Labthink |
|---|---|
| Model | PERME W3/062 |
| Principle | Gravimetric Cup Method (ASTM E96, ISO 2528, GB 1037) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 independent specimens per run |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | PERME-W3/031 |
| Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Resolution | 0.0001 g |
| Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Sample Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Cup Capacity | 3 independent test cups |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 57,000 |
| Test Principle | Gravimetric Cup Method (ASTM E96, ISO 2528, GB 1037 compliant) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C, ±0.1 °C |
| Humidity Control | 10–98% RH, ±1% RH |
| Test Area | 33 cm² |
| Sample Thickness Limit | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Purge Air Velocity | 0.5–2.5 m/s |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Measurement Principle | Gravimetric cup method (ASTM E96, ISO 2528, GB 1037 compliant) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Specimen Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Category | Packaging Industry–Specific WVTR Tester |
| Test Principle | Gravimetric Cup Method (ASTM E96 Desiccant Method) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g |
| Temperature Control | 15–55 °C, ±0.1 °C |
| Humidity Control | 10–98% RH, ±1% RH |
| Test Area | 33 cm² |
| Sample Thickness Limit | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | AC 85–264 V, 47–63 Hz |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Net Weight | 83 kg |
| Compliance | GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 72,000 (based on configuration and regional duties) |
| Test Principle | Gravimetric cup method (weight gain/loss measurement) |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Quantity | 1–3 independent cups |
| Test Accuracy | ±0.01 g/m²·24h |
| System Resolution | 0.0001 g |
| Temperature Control Range | 15–55 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 10–98 %RH (standard 90 %RH) |
| RH Stability | ±1 %RH |
| Sweep Air Velocity | 0.5–2.5 m/s (optional) |
| Test Area | 33 cm² |
| Max. Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions (L×W×H) | 580×680×470 mm |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Type | Gravimetric Cup Method WVTR Tester |
| Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Airflow Velocity | 0.5–2.5 m/s |
| Chamber Volume | 27 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Region | Domestic (China) |
| Model | W3/031 |
| Price Range | USD 28,000 – 56,000 |
| Test Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Resolution | 0.01 g/m²·24h |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Specimen Size | Φ74 mm |
| Number of Test Stations | 3 independent cups |
| Chamber Volume | 27 L |
| Purge Air Velocity | 0.5–2.5 m/s |
| Power Supply | AC 85–264 V, 47–63 Hz |
| Power Consumption | 600 W |
| Net Weight | 83 kg |
| Dimensions (L×W×H) | 580×680×470 mm |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Resolution | 0.0001 g |
| Accuracy | ±0.01 g/m²·24h |
| Temperature Control | 15–55°C (±0.1°C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Cup Capacity | 3 independent cups |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Dimensions | 580 × 680 × 470 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/031 |
| Principle | Gravimetric Cup Method |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Weight Accuracy | ±0.0001 g |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Purge Air Velocity | 0.5–2.5 m/s |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Brand | Labthink |
|---|---|
| Model | W3/031-PERME |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Type | Gravimetric Cup Method WVTR Tester |
| Test Range | 0.1–10,000 g/m²·24h |
| Sample Capacity | 1–3 independent cups |
| Resolution | 0.0001 g |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Sample Thickness | ≤3 mm |
| Sample Diameter | Φ74 mm |
| Chamber Volume | 27 L |
| Air Supply | 0.6 MPa, Φ4 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 83 kg |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W3/062 |
| Test Principle | Gravimetric Cup Method (Weight Loss/Gain) |
| Measurement Range | 0.1–10,000 g/m²·24h (weight loss mode) |
| Sample Capacity | 1–6 independent specimens per test cycle |
| Temperature Control | 15–55 °C (±0.1 °C accuracy) |
| Humidity Control | 10–98% RH (±1% RH accuracy) |
| Test Area | 33 cm² |
| Specimen Thickness Limit | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance Standards | GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Measurement Principle | Gravimetric Cup Method (Weight Change) |
| Test Range | 0.1–10,000 g/m²·24h (Loss Mode), 0.1–2,500 g/m²·24h (Gain Mode) |
| Sample Capacity | 1–6 independent specimens per run |
| Temperature Control | 15–55°C ±0.1°C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance | GB/T 17146, GB 1037, GB/T 16928, ASTM E96, ASTM D1653, ISO 2528, DIN 53122-1, JIS Z0208, TAPPI T464, YBB00092003 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Labthink International Co., Ltd. |
| Model | W3/062 |
| Test Principle | Gravimetric Cup Method (ASTM E96, ISO 2528, GB 1037) |
| Measurement Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 independent specimens per test cycle |
| Temperature Control | 15–55 °C ±0.1 °C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Thickness Limit | ≤3 mm |
| Weight Resolution | 0.001 g |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Principle | Gravimetric Cup Method (Weight Gain/Loss) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 specimens simultaneously |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98 %RH (±1 %RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Chamber Volume | 45 L |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | Labthink |
|---|---|
| Model | W3/062 |
| Measurement Principle | Gravimetric Cup Method (ASTM E96 / ISO 2528) |
| Test Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 independent specimens |
| Temperature Control | 15–55 °C (±0.1 °C) |
| Humidity Control | 10–98% RH (±1% RH) |
| Test Area | 33 cm² |
| Specimen Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | Labthink |
|---|---|
| Model | W3/062-PERME |
| Origin | Shandong, China |
| Manufacturer | Labthink Instruments Co., Ltd. |
| Application Category | Packaging & Medical Film Barrier Testing |
| Test Principle | Gravimetric Cup Method (ASTM E96, GB 1037, ISO 2528) |
| Measurement Range | 0.1–10,000 g/m²·24h (loss mode) |
| Sample Capacity | 1–6 specimens per test cycle (independent channels) |
| Temperature Control | 15–55 °C ±0.1 °C |
| Humidity Control | 10–98% RH ±1% RH |
| Test Area | 33 cm² |
| Specimen Diameter | Φ74 mm |
| Max Thickness | ≤3 mm |
| Weight Resolution | 0.001 g |
| WVTR Resolution | 0.01 g/m²·24h |
| Air Supply | 0.6 MPa, Φ6 mm polyurethane tubing |
| Power | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 80 kg |
| Dimensions | 660 × 580 × 580 mm (L×W×H) |
| Brand | MOCON |
|---|---|
| Origin | Germany |
| Model | AQUATRAN 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Temperature Control Range | 20–40 °C ± 0.2 °C |
| RH Control | 50–90% RH ± 3% RH & 100% RH |
| Test Area (Standard) | 50 cm² |
| Unshielded WVTR Range | 0.05–100 g/(m²·day) |
| Shielded WVTR Range | 0.5–1000 g/(m²·day) |
| Resolution | 0.02 g/(m²·day) |
| Repeatability | ±0.05 g/(m²·day) or ±2%, whichever is greater |
| Dimensions | 39.4 × 30.4 × 58.0 cm |
| Weight | 43.1 kg |
| Power | 100–240 VAC, 50/60 Hz, ≤700 VA |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W 3/38 H |
| Application | PV Backsheet & Encapsulant Barrier Testing |
| Compliance | ASTM F1249 |
| Detection Range | 0.05–200 g/(m²·day) |
| Sensor Type | Patented Modulated Infrared Detector |
| Chamber Configuration | Dual removable test cells (4 samples per run) |
| Control System | Fully automated temperature, RH, and carrier gas flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Measurement Principle | Modulated IR detection of water vapor in carrier gas stream |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/38 H |
| Detection Limit | 0.05 g/(m²·day) |
| Measurement Range | 0.05–200 g/(m²·day) |
| Test Chambers | 4 independent horizontal dual-membrane chambers |
| Compliance | ASTM F1249 |
| Sensor Type | Modulated Infrared (Patented MOCON) |
| Environmental Control | Automated temperature, RH, and N₂ flow |
| Sealing Technology | TruSeal nitrogen purge ring |
| Software Interface | Local PC GUI or optional touchscreen HMI |
| Test Mode Options | QC pass/fail mode, reference film validation, triplicate testing |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN-W® 3/40 |
| Detection Limit | 0.000025 g/(pkg·day) |
| Test Chambers | 4 independent |
| Temperature Range | 10–50 °C |
| RH Range | 30–90 % RH |
| Sensor Type | Modulated Infrared (ASTM F1249 compliant) |
| Automation | Fully automated T/RH/flow control, motorized test cartridge exchange, integrated conditioning & purge |
| Interface | Touchscreen HMI with real-time parameter monitoring |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | AQUATRAN® Model 3 |
| Test Range (Film) | 0.00005–5 g/m²·day |
| Test Range (Container) | 0.00000025–0.025 g/pkg·day |
| Resolution | 0.00001 g/m²·day |
| Repeatability | ±0.00005 g/m²·day |
| Temperature Range | 5–50 °C (±0.2 °C at 100% RH) |
| Humidity Range (Detector Gas) | 5–90% RH & 100% RH |
| (Carrier Gas) | Dry |
| Test Chamber Options | Dual 50 cm² chambers |
| Compliance | ASTM F3299, ISO 15106-3, GB/T 21529-2008, YBB00092003-2015 |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Model | PERMATRAN-W® 1/50 |
| Test Range | 0.1–100 cm³/m²·day |
| Temperature Range | 5–50 °C (W-type configuration) |
| Humidity Range | 35–90 %RH (standard), up to 100 %RH (W-type) |
| Test Area | 2 chambers × 50 cm² |
| Repeatability | ±0.05 g/m²·day or ±3 % of reading (whichever is greater) |
| RH Sensor Accuracy | ±3 %RH |
| Carrier Gas | Dry nitrogen or oil-free compressed air |
| Compliance | ASTM E398, ISO 15106-1, GB/T 30412–2013 |
| Brand | MOCON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PERMATRAN-W® Model 101K |
| Quotation | Upon Request |
| Test Range | 500–100,000 g/m²·day |
| Test Temperature | 20–50 °C with Automatic Temperature Control |
| Atmospheric Pressure Compensation | Standard |
| Flow Rate Compensation | Standard |
| Number of Test Cells | 6 |
| Cell Area | 10 cm² per cell |
| Compliance | ASTM D6701, WSP 001.0.R3 (12) (EDANA & INDA) |