Water Vapor Transmission Rate Tester
Filter
Showing 61–90 of 131 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W533 |
| Measurement Principle | Gravimetric (Cup Method) |
| Test Range | 0.1–10,000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Weight Resolution | 0.1 mg |
| Temperature Control Range | 15–55 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90% RH and 100% RH |
| Humidity Stability | ±1% RH |
| Test Area | 86.54 cm² |
| Specimen Diameter | Φ125 mm |
| Max. Specimen Thickness | ≤5 mm |
| Purge Air Velocity | 0.5–2.5 m/s |
| Interface | Φ4 mm polyurethane tubing |
| Supply Pressure | ≥0.2 MPa |
| Capacity | 3 test stations (expandable to 10) |
| Dimensions | 1680 × 500 × 375 mm |
| Weight | 160 kg |
| Power | 1000 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | W812 |
| Price | USD 55,000 (FOB Guangzhou) |
| Testing Principle | Gravimetric Cup Method (ASTM E96 / GB/T 1037) |
| Test Range | 0.05–10,000 g/(m²·24h) |
| Resolution | 0.0001 g/(m²·24h) |
| Test Stations | 12 |
| Balance Capacity | 220 g |
| Balance Readability | 0.1 mg (optional 0.01 mg) |
| Temperature Control Range | 10–50 °C ±0.1 °C |
| Humidity Control Range | 5–90 %RH ±2 %RH |
| Air Velocity | 0.3–2.5 m/s (optional low-flow 0.03–0.5 m/s) |
| Test Area | 33 cm² |
| Specimen Diameter | Φ74 mm |
| Max. Specimen Thickness | ≤3 mm |
| Test Modes | Gravimetric Gain & Loss Methods |
| Carrier Gas | Compressed Air ≥0.6 MPa |
| Dimensions | 830 × 670 × 440 mm |
| Weight | 75 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | ChP 2025 <4010>, ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, GB/T 17146, GB/T 12704, GB/T 19082, GB/T 21332, TAPPI T464, DIN 53122-1, YBB00092003 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | W900 |
| Price Range | USD 70,000 – 140,000 |
| Measurement Principle | Gravimetric Cup Method (ASTM E96 / GB/T 1037) |
| Test Modes | Gain-Weight & Loss-Weight |
| Test Stations | 9 |
| WVTR Range (Film) | 0.05–10,000 g/m²·24h |
| WVTR Range (Container) | 0.0002–30 g/pkg·24h |
| Mass Resolution | 0.1 mg |
| Temperature Control | 10–50 ±0.1 °C |
| Humidity Control | 5–95% RH, up to 100% RH |
| Airflow Velocity | 0.5–2.5 m/s (optional low-flow: 0.03–0.5 m/s) |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 33 cm² |
| Carrier Gas | Compressed air (≥0.6 MPa), Φ6 mm polyurethane tubing |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W900 |
| Price Range | USD 42,000 – 70,000 |
| Measurement Range (Film) | 0.05–10,000 g/(m²·24h) |
| Measurement Range (Container) | 0.0002–30 g/(pkg·24h) |
| Test Accuracy (Film) | ±0.05 g/(m²·24h) |
| Test Accuracy (Container) | ±0.0002 g/(pkg·24h) |
| Test Stations | 9 |
| Balance Capacity | 210 g |
| Balance Resolution | 0.1 mg |
| Temperature Range | 10–50 ±0.1 °C |
| Humidity Range | 5–95 %RH |
| Air Velocity | 0.5–2.5 m/s (optional low-flow mode: 0.03–0.5 m/s) |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 33 cm² |
| Carrier Gas | Compressed air (≥0.6 MPa) |
| Tubing Interface | Φ6 mm polyurethane |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W900e |
| Price | ¥900,000 |
| Key | Origin: Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | W402 |
| Pricing | Upon Request |
| Test Principle | Infrared Sensor Method (ISO 15106-2, ASTM F1249 compliant) |
| Measurement Range | 0.001–100 g/m²·24h (film) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Humidity Control | 0%RH, 30–90%RH ±1%RH |
| Test Area | 50 cm² |
| Sample Size | 108 mm × 108 mm |
| Max Thickness | ≤3 mm |
| Carrier Gas | High-Purity N₂ (≥99.999%), 0.28 MPa, 0–200 mL/min |
| Touchscreen Interface | 240,000-color 7″ TFT LCD |
| Data Output | Real-time curves (WVTR, T, RH, H₂O concentration), CSV/PDF export via USB or PC software |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2 compliant) |
| Test Range | Standard WVTR range for high-to-medium barrier films |
| Sample Types | Flexible packaging films, laminates, coated papers, pharmaceutical blister foils, PV encapsulation films |
| Compliance | GB/T 26253, ASTM F1249, ISO 15106-2, ISO 2528 |
| Data Output | Real-time WVTR (g/m²·day), permeability coefficient, temperature & RH control logging |
| Environmental Control | Dual-zone temperature and relative humidity regulation |
| Sensor Type | High-stability infrared moisture sensor with auto-zero calibration |
| Throughput | Up to 3 simultaneous test stations (configurable) |
| Interface | Ethernet + USB |
| Software | Labthink TRS v4.2 with 21 CFR Part 11 compliance mode, audit trail, user permission levels |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 98,000 |
| Test Principle | Infrared Detection per ASTM F1249 & ISO 15106-2 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| WVTR Range | 0.02–40 g/(m²·day) (50 cm²), 0.2–400 g/(m²·day) (5 cm²), 1–2000 g/(m²·day) (1 cm²) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (custom) |
| Temp Stability | ±0.05 °C |
| RH Range | 5–90 %RH ±2 %RH |
| Chamber Configuration | Triple independent test chambers |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Inlet | 1/8″ stainless steel tube |
| Power | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Measurement Principle | Infrared Detection (ASTM F1249 / ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (±0.05 °C stability) |
| RH Control | 5–90 %RH (±2 %RH) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied, ≥280 kPa) |
| Power | 120/220 VAC, 50/60 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2 compliant) |
| Test Range | 0.005–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (±0.05 °C stability) |
| RH Control | 5–90 %RH (±1 %RH) |
| Test Chambers | 3 independent chambers (50 cm² standard area each) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied, ≥280 kPa) |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C303H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Range | 0.005–40 g/(m²·day) (50 cm²), 0.005–100 g/(m²·day) (50 cm²), 0.05–400 g/(m²·day) (5 cm² mask), 0.25–2000 g/(m²·day) (1 cm² mask) |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), optional 5–60 °C |
| Temp. Stability | ±0.05 °C |
| RH Range | 5–90 %RH ±1 %RH |
| Test Area | 50 cm² (standard), 5 cm² / 1 cm² (optional masks) |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 500 × 700 mm |
| Weight | 100 kg |
| Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Detection (ASTM F1249, ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 15–50 °C (optional: 5–60 °C), stability ±0.15 °C |
| RH Control | 5–90 %RH ±2% |
| Test Chambers | 6 independent chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max Sample Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥280 kPa |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions (W×D×H) | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Absorption Spectroscopy (ASTM F1249 / ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (optional: 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| RH Range | 5–90 %RH ±2% (at standard temp.) / 100 %RH |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASKs |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Thickness | 3 mm |
| Carrier Gas | ≥99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% 60 Hz or 220 VAC ±10% 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Measurement Principle | Infrared Detection of Water Vapor |
| Standards Compliance | ASTM F1249, ISO 15106-2, GB/T 26253, JIS K7129, YBB00092003-2015 |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| WVTR Range | 0.02–40 g/(m²·day) [50 cm²], 0.2–400 g/(m²·day) [5 cm²], 1–2000 g/(m²·day) [1 cm²] |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (standard), 5–60 °C (optional) |
| Temp. Stability | ±0.15 °C |
| Humidity Range | 100% RH, or 5–90% RH ±2% RH |
| Test Chambers | 6 independent |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂, ≥280 kPa inlet pressure |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000 – 57,000 |
| Test Principle | Infrared Detection (ASTM F1249, ISO 15106-2) |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Repeatability | ±0.02 g/(m²·day) or ±2%, whichever is greater |
| Temperature Range | 15–50 °C (optional: 5–60 °C) |
| Temp. Stability | ±0.15 °C |
| RH Range | 5–90 %RH ±2% (at standard temp.) / 100 %RH |
| Chamber Count | 6 independent test chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 11.2 cm × 11.2 cm |
| Max. Sample Thickness | 3 mm |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Inlet Pressure | ≥280 kPa |
| Power Supply | 120 VAC ±10% 60 Hz / 220 VAC ±10% 50 Hz |
| Dimensions (W×D×H) | 600 mm × 490 mm × 660 mm |
| Net Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C306H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Range | 0.02–40 g/(m²·day) @ 50 cm² |
| Resolution | 0.0001 g/(m²·day) |
| Temperature Range | 15–50 °C (±0.15 °C stability) |
| Humidity Range | 5–90 %RH (±2 %RH) |
| Test Area | 50 cm² (standard), optional 5 cm² or 1 cm² MASK fixtures |
| Chamber Configuration | 6 independent test cells |
| Carrier Gas | 99.999% N₂ |
| Power Supply | 120 VAC ±10% / 60 Hz or 220 VAC ±10% / 50 Hz |
| Dimensions | 600 × 490 × 660 mm |
| Weight | 100 kg |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90% RH ±1% RH (with optional 100% RH capability) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L (optional) |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003–2015 |
| Optional Features | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Module, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90% RH (±1% RH), optional 100% RH |
| Test Chambers | 3 independent chambers |
| Standard Test Area | 50 cm² |
| Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | 3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer | Labthink Co., Ltd. |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| RH Control | 5–90% RH (±1% RH), optional 100% RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Package Volume | 3 L |
| Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Carrier Gas | ≥99.999% N₂, ≥0.28 MPa (40.6 psi) |
| Interface | 1/8″ stainless steel tubing |
| Optional Compliance | 21 CFR Part 11, GMP Data Integrity, DataShield™ Audit-Trail System |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Coulometric Electrolytic Sensor (ISO 15106-3) |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Packaging Test Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Compliance Modules | DataShield™ Data Integrity System, 21 CFR Part 11 Audit Trail, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Thickness | ≤3 mm |
| Sample Size | 108 mm × 108 mm |
| Packaging Test Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa |
| Gas Inlet Port | 1/8″ stainless steel tubing |
| Data Compliance | Optional CFR 21 Part 11, GMP-compliant audit trail, DataShield™ secure data management |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Price Range | USD 28,000 – 70,000 |
| Test Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH (100 %RH optional) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, min. pressure 0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Optional Compliance Modules | DataShield™ Data Integrity System, 21 CFR Part 11 compliance package, GMP-compliant computer system validation support |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90 %RH ±1 %RH (up to 100 %RH optional) |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Sample Thickness | 3 mm |
| Packaging Test Capacity | up to 3 L (optional) |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa |
| Gas Inlet Fitting | 1/8″ stainless steel tubing |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Data Integrity Options | CFR 21 Part 11-compliant audit trail, DataShield™ secure data management (optional) |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Testing Principle | Electrolytic (Coulometric) Moisture Detection |
| Standards Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2%, whichever is greater |
| Temperature Control | 10–55 °C (±0.2 °C) |
| Humidity Control | 5–90 %RH (±1 %RH), optional 100 %RH |
| Test Chambers | 3 independent |
| Sample Area | 50 cm² |
| Max Sample Size | 108 mm × 108 mm |
| Max Thickness | ≤3 mm |
| Packaging Test Capacity | up to 3 L (optional) |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Inlet Pressure | ≥0.28 MPa (40.6 psi) |
| Gas Interface | 1/8″ stainless steel tubing |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Support | Optional 21 CFR Part 11 compliance package |
| GMP Computer System Validation Support | Optional |
| Brand | Labthink |
|---|---|
| Model | C330H |
| Measurement Principle | Electrolytic (Coulometric) Moisture Sensor per ISO 15106-3 |
| Test Range | 0.005–50 g/(m²·day) |
| Resolution | 0.001 g/(m²·day) |
| Repeatability | ±0.005 g/(m²·day) or ±2% (whichever is greater) |
| Temperature Control | 10–55 °C ±0.2 °C |
| Humidity Control | 5–90% RH ±1% RH (with optional 100% RH capability) |
| Test Chambers | 3 independent, simultaneous |
| Sample Area | 50 cm² (standard) |
| Max. Sample Size | 108 mm × 108 mm |
| Max. Sample Thickness | ≤3 mm |
| Package Testing Capacity | up to 3 L |
| Carrier Gas | ≥99.999% N₂, inlet pressure ≥0.28 MPa (40.6 psi), 1/8″ metal tubing interface |
| Compliance | ISO 15106-3, ASTM F3299, GB/T 21529, YBB 00092003-2015 |
| Optional Modules | DataShield™ Data Integrity System, CFR 21 Part 11 Compliance Package, GMP Computer System Validation Support |
| Brand | Labthink |
|---|---|
| Model | C360H |
| Principle | Gravimetric (ASTM E96, GB/T 1037, GB/T 16928) |
| Test Modes | Gain & Loss Methods |
| Test Stations | 12 |
| Temperature Range | 20–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Max WVTR (Loss) | 10,000/n g/(m²·day) |
| Max WVTR (Gain) | 1,200 g/(m²·day) |
| Sample Diameter | Φ74 mm |
| Sample Thickness | ≤3 mm |
| Test Area | 33 cm² |
| Carrier Gas | Compressed Air (≥0.6 MPa) |
| Drying System | Core-free Long-life Desiccant Module |
| Humidification | Fog-free Internal Humidifier |
| Data Compliance | Optional 21 CFR Part 11 & GMP Audit Trail |
| Software | DataShield™ Secure Data Management Platform |
| Brand | Labthink |
|---|---|
| Model | C360H |
| Testing Principle | Gravimetric (Weight Gain/Loss Method) |
| Standards Compliance | ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, TAPPI T464, DIN 53122-1, YBB00092003-2015 |
| Test Stations | 12 |
| Temperature Range | 20–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max. Sample Thickness | ≤3 mm |
| Effective Test Area | 33 cm² |
| WVTR Range (Weight Loss Mode) | up to 10,000/n g/(m²·day) or 645/n g/(100 in²·day), n = 1–12 |
| WVTR Range (Weight Gain Mode) | up to 1200 g/(m²·day) or 77 g/(100 in²·day) per station |
| Carrier Gas | Compressed Air (≥0.6 MPa) |
| Gas Drying | Long-life desiccant module (no cartridge replacement, >20,000 h service life) |
| Humidification | Internal fog-free steam generator |
| Airflow Control | Automated, real-time regulated |
| Data Management | DataShield™ secure audit trail system |
| Regulatory Options | Optional 21 CFR Part 11 compliance package, GMP-compliant computer system validation support |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C360H |
| Testing Methods | Gravimetric Gain & Loss Modes |
| Maximum WVTR (Loss Mode) | 10,000/n g/(m²·day) (n = 1–12) |
| Maximum WVTR (Gain Mode) | 1,200 g/(m²·day) per station |
| Test Stations | 12 |
| Temperature Range | 20–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Sample Thickness | ≤3 mm |
| Test Area | 33 cm² |
| Carrier Gas | Compressed Air (≥0.6 MPa) |
| Desiccant System | Core-free Long-life Dryer (20,000 h service life) |
| Humidification | Fog-free Integrated Humidifier |
| Data Management | DataShield™ Audit-Trail-Enabled Software |
| Regulatory Options | Optional 21 CFR Part 11 Compliance Package |
| GMP Computer System Validation Support | Optional |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | C360M |
| Price Range | USD 28,000 – 56,000 |
| Test Principle | Gravimetric (ASTM E96 / GB 1037) |
| Test Methods | Gain-in-weight & Loss-in-weight |
| Test Stations | 6 independent chambers |
| Temperature Range | 15–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Effective Test Area | 33 cm² |
| Carrier Gas | Compressed air (≥0.6 MPa) |
| Drying System | Core-free long-life desiccant module (20,000 h service life) |
| Humidification | Internal mist-free steam generator |
| Airflow Control | Auto-regulated laminar flow |
| Data Compliance | Optional 21 CFR Part 11, GMP-compliant audit trail, DataShield™ secure export (CSV, PDF, XML) |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C360M |
| Test Principle | Gravimetric (ASTM E96 / GB 1037 compliant) |
| Test Modes | Gain-Weight & Loss-Weight |
| Test Stations | 6 independent chambers |
| Temperature Range | 15–55 °C ±0.2 °C |
| Humidity Range | 10–90 %RH ±1 %RH |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Effective Test Area | 33 cm² |
| WVTR Range (Loss-Weight) | up to 10,000/n g/(m²·day) [n = 1–6] |
| WVTR Range (Gain-Weight) | up to 1200 g/(m²·day) per station |
| Carrier Gas | Compressed air (≥0.6 MPa) |
| Drying System | Core-free, 20,000-hour service life |
| Humidification | Fog-free internal humidifier |
| Data Management | DataShield™ audit-trail-enabled software |
| Regulatory Compliance Options | 21 CFR Part 11, GMP-compliant computer system validation support |