X Ray Stress Analyzer
Filter
Showing 1–30 of 106 results
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AreX D |
| X-ray Source | 50 W Mo microfocus tube with Zr filter |
| Cooling | Air-cooled |
| Detection | High-resolution USB camera for precise sample positioning |
| Safety | Interlocked X-ray shielding system |
| Measurable Diffraction Peaks | Austenite (220), (311) |
| Measurement Time | < 3 minutes per sample |
| Compliance | ASTM E975-22 Standard |
| Minimum Detectable Austenite Content | 0.5 vol% |
| Sample Compatibility | Flat, polished metallic specimens (steel, stainless steel, tool steels, bearing alloys) |
| Software | Integrated Windows-based analysis suite with peak integration, phase quantification, and report generation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | AREX L |
| Compliance | ASTM E975 |
| Measurement Principle | X-ray Diffraction (XRD) |
| Detection Limit | ≤0.5% austenite |
| Target Material | Ferrous alloys (steel, cast iron, heat-treated components) |
| X-ray Source | High-power ceramic X-ray tube |
| Optics | High-focus single-capillary collimator |
| Detector | High-resolution CCD detector |
| Stability Control | Precision closed-loop feedback circuit for HV/current regulation |
| Data Acquisition | Multi-peak intensity ratio analysis (austenite {220}, {311} / ferrite {200}, {211}) |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EDGE |
| Compliance | ASTM E915, EN 15305 |
| Detector | Linear silicon strip detector with single-photon counting technology |
| Cooling | Air-cooled |
| X-ray Source | Interchangeable microfocus X-ray tubes |
| Fluorescence Suppression | Integrated X-ray fluorescence rejection |
| Measurement Time | Minutes per point (vs. hours for conventional systems) |
| Portability | Fully integrated into carry-on compliant transport case |
| Safety Options | Optional radiation shielding enclosure for benchtop operation |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | MagStress5c |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Sample Type | Ferromagnetic Metals (e.g., carbon steel, alloy steel, cast iron) |
| Portability | Integrated battery-powered handheld system with touch-screen interface and USB connectivity |
| Output | Quantitative residual stress in MPa, graphical trend visualization, calibration curve support |
| Compliance Context | Designed for field-deployable non-destructive evaluation (NDE) in accordance with ASTM E1447, ISO 20956, and EN 10328 guidelines for magnetic methods of stress assessment |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | STRESS-X |
| Compliance | ASTM E915, EN 15305 |
| Motion System | 6-axis robotic arm |
| Deployment Options | Benchtop shielded enclosure or mobile four-wheel alloy cart |
| Measurement Principle | Sin²ψ X-ray diffraction (XRD) |
| Application Scope | Non-destructive residual stress mapping on metallic components |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DS-21L |
| X-ray Tube Power | 3000 W |
| 2θ Angular Range | 105°–170° (continuously adjustable) |
| ψ Angular Range | −57° to +57° |
| Available Anode Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Minimum Focal Spot Size | 0.1 mm |
| Detector Configuration | Dual Linear Semiconductor Array Detectors |
| Individual Detector 2θ Coverage | 35° |
| Detector Linear Count Rate | >10⁹ CPS |
| Positioning System | Integrated Laser Displacement Sensor + Motorized Z-axis (600 mm travel) + Manual/Automatic XYZΦ Sample Stage (X: 300 mm, Y: 200 mm, Φ: 0–360°) |
| Measurement Methods | Sin²ψ (both side-inclination and co-inclination modes) |
| Residual Stress Repeatability (Fe powder reference) | < ±5 MPa (n = 5) |
| Radiation Shielding | Fully Enclosed Lead-Glass Enclosure Compliant with ANSI N43.2 |
| Standards Compliance | ASTM E915-2010, EN 15305:2008, GB/T 7704–2016 |
| Optional Target Materials | Cr, Mn, Cu, Co, Fe, V |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DS-21P |
| X-ray Tube Power | 300 W |
| 2θ Angular Range | 105°–170° (continuously adjustable) |
| ψ Angular Range | −45° to +45° |
| Available Anode Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | DS-23MINI |
| X-ray Tube Power | 50 W |
| 2θ Angular Range | 140°–170° (continuously adjustable) |
| ψ Angular Range | −35° to +35° |
| Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Detector | Dual semiconductor linear array (256 × 256 pixels), linear count rate > 10⁹ cps |
| Stress Measurement Repeatability (Fe powder) | < ±5 MPa (n = 5) |
| Compliance | ASTM E915-2010, EN 15305-2008, GB/T 7704-2017 |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DST-17 |
| X-ray Tube Power | 3000 W |
| 2θ Angular Range | 45°–170° (continuously adjustable) |
| ψ Angular Range | −25° to +50° |
| Target Materials | Cr, Cu, Mn, Ti, Co, V, Fe |
| Angular Resolution (2θ) | 0.0001° |
| 2θ Repeatability | < 0.003° |
| Stress Measurement Accuracy | ±5 MPa |
| Detector | High-resolution Silicon Drift Detector (SDD), linear array configuration |
| Sample Positioning | Laser displacement sensor with < 3 µm repeatability |
| Motion System | 4-axis motorized sample stage + 360° precision rotation stage |
| Radiation Shielding | Fully enclosed lead-glass enclosure compliant with ANSI N43.2 |
| Standards Compliance | ASTM E915-2010, EN 15305-2008, GB/T 7704-2016, ISO 9001 |
| Brand | Pulstec |
|---|---|
| Origin | Japan |
| Model | μ-X360J |
| X-ray Tube | 30 kV, 1.6 mA |
| Target Material | Standard Cr (optional V, Cu, Co, Mn) |
| Collimator | Ø1 mm (custom sizes available) |
| Detector | Full 2D area detector |
| Measurement Time | ~60 s per point |
| Power Supply | 130 W, 110–240 V, 50–60 Hz |
| Cooling | Air-cooled, no water chiller required |
| Portability | Battery-operated, weight ≈ 8.1 kg |
| Compliance | JSMS-SD-14-20 (Japan) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | SmartSite RS |
| Weight | 3 kg |
| Dimensions (Test Head) | 114 mm (W) × 248 mm (D) × 111 mm (H) |
| Detector Type | Dual semiconductor-based 2D area detectors |
| X-ray Source | Microfocus sealed-tube anode (Cr, Fe, Co, Cu selectable) |
| ψ-angle range | −60° to +60° |
| 2θ-angle range | 70° to 160° (adjustable per material and reflection) |
| Safety | Integrated laser alignment, 3-axis accelerometer for tilt monitoring, optional lead-lined shielding enclosure for lab use |
| Control Interface | Android-based touchscreen tablet with LAN/Wi-Fi connectivity |
| Compliance | IEC 61000-6-3, IEC 61000-6-4, JIS Z 4901:2020 (X-ray equipment safety), ISO 21940-11 (residual stress measurement — XRD method) |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | RollScan 300 |
| Price | Upon Request |
| Power Supply | 90–260 VAC, 49–61 Hz, Single-Phase |
| Inrush Current (Cold Start) | 40 A @ 115 VAC, 80 A @ 230 VAC |
| Power Consumption (Charging Battery) | 150 VA |
| Typical Operating Power | 100 VA |
| Magnetization Frequency Range | 1.0–1000 Hz |
| Magnetization Voltage Range | 0–16 V |
| Signal Analysis Filter Bands | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Channel Configuration | Single-Channel Standard (Multi-Channel Optional) |
| Sensor Interface | Detachable Pre-Amplified Probes |
| Compatible Materials | Ferritic steels, iron-based alloys, nickel-based superalloys, cobalt-based alloys |
| Signal Processing | Real-Time Digital Signal Processor (DSP) |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Authorization Status | Authorized Distributor |
| Origin Category | Imported |
| Model | BearingScan |
| Pricing | Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BearingScan |
| Pricing | Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | BearingScan400 |
| Type | Electromagnetic Acoustic Transducer (EMAT)-Based Non-Destructive Testing System for Grinding Burn and Heat Treatment Defect Detection |
| Compliance | ISO 17843, ASTM E3296 (under development), GLP-compliant data audit trail capability |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Camscan |
| Power Supply | 90–260 VAC, 49–61 Hz |
| Input Current (Cold Start) | 40 A @ 115 VAC / 80 A @ 230 VAC |
| Power Consumption | 100 VA (Normal), 150 VA (Battery Charging) |
| Magnetization Frequency Range | 1.0–1000 Hz |
| Magnetization Voltage | 0–16 V |
| Signal Analysis Bandwidths | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Channel Configuration | Single-channel (standard), optional multi-channel |
| Enclosure Rating | IP20 |
| Operating Temperature | 0–40 °C |
| Operating & Storage Humidity | 10–90 % RH (non-condensing) |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Camscan |
| Power Supply | 90–260 VAC, 49–61 Hz, single-phase |
| Max Inrush Current | 40 A @ 115 VAC / 80 A @ 230 VAC |
| Max Power Consumption (charging) | 150 VA |
| Nominal Power Consumption | ≤100 VA |
| Magnetization Frequency Range | 1.0–1000 Hz |
| Magnetization Voltage | 0–16 V |
| Signal Analysis Bandwidths | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Channel Configuration | Single-channel (expandable) |
| Probe Compatibility | Interchangeable electromagnetic transducers for cam lobes, journal surfaces, and curved geometries |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CamScan |
| Power Supply | 90–260 VAC, 47–63 Hz, single-phase |
| Rated Power | 120 VA |
| Operating Temperature | 10–50 °C (non-condensing) |
| Operating Humidity | 10–90 % RH (non-condensing) |
| Magnetization Frequency Range | Sine wave 1–1000 Hz, Triangle wave 1–150 Hz |
| Demagnetization | Automatic |
| Control Architecture | Industrial PLC + Embedded PC with Real-Time OS |
| Compliance | Designed for ISO 10893-13, ASTM E3022, and EN 10204 Type 3.1 applications |
| Brand | Stresstech Oy |
|---|---|
| Country of Origin | Finland |
| Model | Camscan |
| Magnetization Frequency | Sine Wave 1–1000 Hz / Triangle Wave 1–150 Hz |
| Peak-to-Peak Magnetization Voltage | 0–16 V |
| Demagnetization Analysis Filter Bands | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Dimensions | 364 W × 156 H × 316 D mm |
| Interface | Ethernet, USB |
| Software | ViewScan Data Acquisition & Visualization Suite |
| Operating Modes | Single-Channel and Multi-Channel Probe Configurations |
| Measurement Time per Location | ~3–5 seconds |
| User Interface | Multilingual (English, German, French, Chinese, Russian) with Password-Protected Access |
| Compliance | Designed for GLP/GMP-aligned NDT workflows |
| Key | Brand: Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Camscan |
| Power Supply | 90–260 VAC, 49–61 Hz, single-phase |
| Max Inrush Current | 40 A @ 115 VAC / 80 A @ 230 VAC |
| Max Power Consumption (battery charging) | 150 VA |
| Normal Max Power Consumption | 100 VA |
| Magnetization Frequency Range | 1.0–1000 Hz |
| Magnetization Voltage Range | 0–16 V |
| Signal Analysis Filter Bands | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Channel Configuration | Single-channel (expandable architecture) |
| Compliance | Designed for ISO 20022-1, ASTM E3022, and EN 10204 Type 3.1 documentation support |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Camscan |
| Application | Non-Destructive Grinding Burn and Heat Treatment Defect Detection on Rotating Symmetric Components |
| Measurement Principle | X-Ray Diffraction (XRD) Based Residual Stress & Microstructural Change Analysis |
| Compliance | ASTM E915, ISO 21943, EN 15305 |
| Automation Level | Semi-Automatic with Motorized Self-Aligning Sensor Arm |
| Sample Handling | Benchtop or Near-Line Integration for In-Process QC |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | Camscan |
| Power Supply | 90–260 VAC, 49–61 Hz |
| Input Current (Cold Start) | 40 A @ 115 VAC / 80 A @ 230 VAC |
| Power Consumption | 100 VA (Normal), 150 VA (Battery Charging) |
| Magnetization Frequency Range | 1.0–1000 Hz |
| Magnetization Voltage | 0–16 V |
| Signal Analysis Bandwidths | 10–70 kHz, 70–200 kHz, 200–450 kHz |
| Channel Configuration | Single-channel standard (multi-channel optional) |
| Measurement Time per Lobe | 6–8 seconds |
| Detection Principle | Magnetic Barkhausen Noise (MBN) |
| Compliance | Designed for aerospace NDT per ASTM E1444/E3023, ISO 10893-13, and EN 10228-5 |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CamScan1000 |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Cycle Time | 6–8 seconds per lobe |
| Channel Configuration | Single- or Multi-channel |
| Detection Type | Non-destructive, quantitative surface burn assessment |
| Alarm Threshold | User-definable |
| Compliance | Designed for ISO/IEC 17025-aligned QA environments |
| Application Scope | In-line and off-line camshaft inspection |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CamScan200 |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) Analysis |
| Detection Speed | 6–8 seconds per cam lobe |
| Channel Configuration | Single- or multi-channel (up to 4 lobes simultaneously) |
| Output | Quantitative burn severity index, spatial defect localization, user-definable alarm thresholds |
| Compliance | Designed for ISO 17845, ASTM E3019, and EN 10327-based inspection protocols |
| Portability | Benchtop with optional portable probe module |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CrankScan |
| Pricing | Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CrankScan |
| Pricing | Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CrankScan |
| Pricing | Upon Request |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CrankScan |
| Detection Principle | Magnetic Barkhausen Noise (MBN) |
| Measurement Type | Non-Destructive Surface Integrity Assessment |
| Application Scope | Crankshafts, Camshafts, Gears, Bearings, Fuel Injectors, Piston Rods, Landing Gear Components |
| Probe Configurations | Single-Channel & Multi-Channel Modular Probes (Curved, Contoured, Miniature, High-Resolution) |
| Environmental Rating | IP54 |
| Typical Measurement Time per Location | < 5 Seconds |
| Compliance Framework | ASTM E3029–23 (Standard Guide for MBN Testing of Ferromagnetic Components), ISO 28079:2011 (Non-destructive testing — Magnetic Barkhausen noise testing — General principles), Supports GLP/GMP Audit Trail via Software Logging |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Manufacturer | Stresstech Oy |
| Model | CrankScan |
| Detection Principle | Magnetic Barkhausen Noise (MBN) |
| Compliance | ISO 25178-2, ASTM E3069, EN 10327 |
| Portability | Handheld with Integrated Probe & Real-Time Display Unit |
| Data Output | Digital Signal Processing (DSP) with Threshold-Based Alarm Logic |
| Software Platform | Stresstech WinView v5.2 (FDA 21 CFR Part 11 Compliant Audit Trail, GLP/GMP-Ready Export Formats) |
| Brand | Stresstech Oy |
|---|---|
| Origin | Finland |
| Model | CrankScan |
| Measurement Principle | Magnetic Barkhausen Noise (MBN) |
| Channel Options | Single-Channel or Multi-Channel |
| Typical Measurement Time | 6–8 seconds per measurement location |
| Probe Configurations | Interchangeable probes for journal surfaces, flanks, fillets, and complex geometries |
| Environmental Rating | Industrial-grade, operational in harsh workshop conditions |
| Compliance | Designed for ISO 10893-12, ASTM E3071, and EN 10327-compliant non-destructive evaluation workflows |
| Application Scope | Crankshafts, camshafts, bearings, gears, landing gear components, and other ferromagnetic case-hardened or induction-hardened steel parts |