BrandKehua Biosciences (KHB)
OriginShanghai, China
ModelST-960
Detection MethodAbsorbance (Photometric)
Function TypeMultifunctional
Automation LevelFully Automatic
Measurement ModesAbsorbance, Factor Calculation, Standard Concentration, Standard Curve, Single-Threshold, Dual-Threshold, Categorical Classification, Column Subtraction, Point-to-Point
Optical System8-Channel High-Precision Fiber Optic Path
Wavelength Range400–1000 nm
Absorbance Range0.000–4.500 Abs
Linearity Range0.000–3.000 Abs
Wavelength Accuracy±5 nm (at center wavelength)
Detection Speed<5 seconds per 96-well plate (single or dual wavelength)
Resolution0.001 Abs
Light SourceLong-Life LED Cold Light Source
Display7-inch True-Color Touchscreen (840 × 480 resolution)
Filter Positions8 positions
Data StorageInternal high-capacity memory
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKehua Biosciences (KHB)
OriginShanghai, China
ModelST-36W
Instrument TypeMultifunctional Plate Washer
Wash Head Configuration8-channel or 12-channel
Wash Solution & Waste Reservoirs2 L each
Soaking TimeProgrammable
Wash CyclesAdjustable
Residual Volume per Well≤1 µL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKHB
OriginShanghai, China
ModelST-96W
Instrument TypeMultifunctional Plate Washer
Wash Head96-pin
Rinse Head Configuration1–8 independent rinse channels
Wash Solution Channels2
Waste Liquid Channels2
Soak Time Range0–999 s
Wash Cycles1–100
Residual Volume per Well≤ 0.8 µL
Orbital Shaking FunctionAdjustable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKHB
OriginShanghai, China
ModelST-360
Detection MethodAbsorbance (Photometric)
Function TypeMultifunctional
Automation LevelFully Automatic
Assay ModesAbsorbance, Factor Calculation, Standard Concentration, Standard Curve, Single-Threshold, Dual-Threshold, Categorical Classification, Column Subtraction, Point-to-Point
Measurement ConfigurationsSingle-Wavelength, Dual-Wavelength, Dual-Time, Kinetic, Multi-Wavelength, PC-Controlled
Light SourceHalogen Lamp
Wavelength Range400–750 nm
Absorbance Range0.000–4.000 A
Linearity (0–3 A)≥0.99
Wavelength Measurement Speed3 s per wavelength
Resolution0.001 A
Repeatability≤±0.005 A
Optical Channels8-channel fiber-optic detection (optional reference channel)
Filter Positions8 positions (standard: 405, 450, 492, 630 nm
optional414, 546, 578, 690 nm)
Plate Handling96-well microplates only
Vibration FunctionAdjustable amplitude and duration
DisplayLarge LCD with full-dot-matrix Chinese interface
Data Storage500 assay protocols + 1,100 full 96-well runs (expandable)
SoftwareIntegrated qualitative/quantitative analysis suite with customizable equations, curve-fitting models (linear, quadratic, log-log, 4PL, 5PL), QC tools (Levey-Jennings, Westgard rules), and user-defined plate layout templates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKehua Biosciences (KHB)
OriginShanghai, China
ModelST-96WT
Instrument TypeMultifunctional Plate Washer
Wash Head96-pin
Rinse Head Configuration1–8 adjustable rinse lines
Wash Solution Channels2 independent wash solution inlets
Waste Liquid Channels2 dedicated waste outlets
Soak Time Range0–999 seconds
Wash Cycles0–100 cycles
Residual Liquid Volume≤ 0.8 µL per well
Orbital Shaking FunctionAdjustable speed and duration