- All
- Favorite
- Popular
- Most rated
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Gentier 96E/96R |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Format | Standard 96-Well Plate |
| Throughput | 96 samples per run |
| Interchangeable Block | No |
| Effective Reaction Volume Range | 0–100 µL |
| Heating Rate | ≥6.1 °C/s |
| Cooling Rate | Average ≥2.8 °C/s |
| Temperature Uniformity | ≤±0.1 °C across block |
| Number of Detection Channels | 4 or 6 (model-dependent) |
| Excitation Source | High-Efficiency LED Array |
| Detection Sensitivity | High (capable of detecting ≤10 copies/µL input DNA with standard assay conditions) |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP-aligned data integrity features |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Panall 8000 |
| Instrument Type | Real-Time Quantitative PCR System |
| Sample Throughput | 1–8 samples |
| Modular Exchangeability | Not supported |
| Effective Reaction Volume Range | Max sample volume ≤ 2/3 of tube capacity |
| Heating Rate | Avg ≥ 4.5°C/s |
| Cooling Rate | Avg ≥ 3.5°C/s |
| Temperature Uniformity | ±0.2°C across wells |
| Temperature Accuracy | ≤ ±0.1°C |
| Temperature Control Precision | ≤ ±0.1°C |
| Detection Channels | 4 |
| Light Source | High-Stability LED Array |
| Detection Sensitivity | 99.99% (based on validated assay performance under ISO 13485-controlled manufacturing) |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements for regulated laboratories |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Model | Gentier 48E / 48R |
| Sample Throughput | 48 wells |
| Interchangeable Modules | No |
| Effective Reaction Volume Range | 0–100 µL |
| Max Heating Rate | ≥8.0 °C/s |
| Max Cooling Rate | ≥6.2 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Temperature Uniformity | ≤±0.1 °C |
| Detection Channels | 4-channel (Gentier 48E) / 2-channel (Gentier 48R) |
| Excitation Source | High-intensity LED |
| Emission Detection | Photodiode-based fluorescence detection |
| Fluorescence Scan Time | ≤2 s for full 48-well scan (4-color or 2-color) |
| Excitation Wavelengths | Ch1: 465 nm, Ch2: 527 nm, Ch3: 580 nm, Ch4: 632 nm (48E) |
| Emission Wavelengths | Ch1: 510 nm, Ch2: 563 nm, Ch3: 616 nm, Ch4: 664 nm (48E) |
| Linearity (R²) | ≥0.990 |
| Ct Value Reproducibility (CV%) | ≤0.5% |
| Ct Linearity (r) | ≥0.999 |
| Thermal Gradient Support | 35–100 °C, span 1–40 °C |
| Thermal Cycling Range | 0.0–100.0 °C |
| Hot Lid Temperature Range | 40–110 °C |
| Power Supply | AC 220 V (±10%), 50 Hz, 600 VA |
| Dimensions (W×L×H) | 260 × 400 × 260 mm |
| Weight | 11 kg |
| Display | 7-inch full-color capacitive touchscreen |
| Data Storage Capacity | ≤1000 experiment files |
| Software Functions | Absolute quantification, relative quantification, melting curve analysis, high-resolution melting (HRM), SNP genotyping, endpoint fluorescence, isothermal amplification fluorescence analysis |
| Compliance Features | Audit trail support, user access levels, electronic signature readiness (aligned with FDA 21 CFR Part 11 principles), GLP/GMP-compatible data handling protocols |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Gentier 96R |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Format | Standard 96-Well Plate |
| Throughput | 96 samples per run |
| Interchangeable Thermal Block | No |
| Effective Reaction Volume Range | 0–100 µL |
| Maximum Heating Rate | ≥6.1 °C/s |
| Cooling Rate | Average ≥2.8 °C/s |
| Temperature Uniformity | ≤±0.1 °C |
| Temperature Accuracy | ≤±0.1 °C |
| Detection Channels | 4 |
| Light Source | High-Efficiency Long-Life LED |
| Optical Detection Method | Top-Illumination & Top-Scanning with Simultaneous Multi-Channel Per-Well Acquisition |
| Fluorescence Scan Time | ≤7 seconds for full 96-well plate across all 4 channels |
| Dynamic Fluorescence Range | Adjustable per reagent kit |
| Linearity (r) | ≥0.999 |
| Ct Value Reproducibility (CV) | ≤0.5% |
| Supported Assay Types | Absolute Quantification, Relative Quantification, Genotyping (SNP), Melting Curve Analysis, High-Resolution Melting (HRM), Endpoint Fluorescence Detection |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, User Role-Based Access Control, LIS Integration (CSV/Excel/TXT export, open API), GLP/GMP-aligned data integrity features |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Gentier Mini / Mini+ |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 16 wells |
| Interchangeable Thermal Block | No |
| Effective Reaction Volume Range | 0–100 µL |
| Max Heating Rate | 5.0 °C/s |
| Max Cooling Rate | 4.0 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Detection Channels | 4 |
| Light Source | High-Efficiency LED |
| Sensitivity Mode | High-Sensitivity Detection |
| Software Functions | Absolute Quantification, Relative Quantification, Melting Curve Analysis, High-Resolution Melting (HRM), Genotyping, Endpoint Fluorescence Analysis |
| Connectivity | Ethernet, USB, Wi-Fi |
| Display | 7-inch Full-Color Capacitive LCD Touchscreen |
| Dimensions | 205 × 156 × 153 mm (L×W×H) |
| Weight | 3.2 kg |
| Data Storage | ≥1,000 runs onboard |
| Power Failure Recovery | Yes — resumes interrupted runs upon reboot |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Model | Gentier X3 |
| Sample Throughput | 96-well (3 × 32-well independent modules) |
| Effective Reaction Volume Range | 0–100 µL |
| Max Heating Rate | ≥6.2 °C/s |
| Avg Heating Rate | ≥4.5 °C/s |
| Avg Cooling Rate | ≥3.5 °C/s |
| Max Cooling Rate | ≥5.0 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Temperature Uniformity | ±0.2 °C |
| Light Source | High-Efficiency LED Array |
| Fluorescence Detection Channels | 6 |
| Fluorescence Scan Time per Module | ≤2 s |
| Optical Linearity | r ≥ 0.990 |
| Inter-Run CV | ≤1% |
| Power Supply | AC 220 V, 50 Hz, 1200 VA |
| Dimensions (W×D×H) | 380 × 410 × 395 mm |
| Weight | 34 kg |
| Onboard Display | 13.3″ Full-Color Touchscreen (Adjustable Tilt) |
| Standalone Operation | Supported |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP data integrity features |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer | TIANLONG Biotech Co., Ltd. |
| Model | Fascan 48E |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48 |
| Interchangeable Block | No |
| Temperature Range | 4.0°C – 99.0°C |
| Temperature Accuracy | ≤ ±0.3°C (40.0°C – 99.0°C), ≤ ±1.0°C (4.0°C – 39.9°C) |
| Well-to-Well Temperature Uniformity | CV ≤ 0.5% |
| Detection Channels | 4 |
| Excitation Wavelengths | 470 nm, 523 nm, 571 nm, 630 nm |
| Emission Wavelengths | 525 nm, 564 nm, 612 nm, 670 nm |
| Light Source | High-Brightness Maintenance-Free LED |
| Detector | Photodiode |
| Sensitivity | High (capable of detecting single-copy nucleic acid targets under optimized assay conditions) |
| Data Storage Capacity | ≤ 1000 experiment setup/data files |
| Control Interface | 7-inch full-color touchscreen or PC-based software |
| Dimensions | 400 mm (L) × 260 mm (W) × 260 mm (H) |
| Weight | 11 kg |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Model | Aurora7500 |
| Sample Throughput | 96-well format |
| Temperature Accuracy | ±0.2 °C |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Genesy 96T |
| Instrument Category | Real-Time PCR System |
| Sample Throughput | 96-well format (0.2 mL) |
| Interchangeable Block | No |
| Max Heating Rate | ≥3.5 °C/s |
| Max Cooling Rate | ≥2.5 °C/s |
| Block Temperature Range | 4.0–99.9 °C |
| Gradient Capability | 12-zone linear gradient (range: 35.0–100.0 °C |
| width | 1.0–40.0 °C) |
| Temperature Uniformity | ±0.2 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Thermal Lid Temperature Range | 40–110 °C |
| Power Supply | AC 100–240 V, 50–60 Hz, 600 VA |
| Dimensions (W×D×H) | 260 × 400 × 260 mm |
| Weight | 11 kg |
| Noise Level | <55 dB(A) |
| Operating System | Embedded Linux |
| Interface | USB 2.0, Ethernet |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements |
Show next