- All
- Favorite
- Popular
- Most rated
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PANA 9600X |
| Price | USD 84,000 (FOB Shanghai, ex-works pricing subject to configuration and regional compliance certification) |
| Brand | Kehua (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | Aurora Flexi96s |
| Throughput | 96 samples in ≤30 min (pre-analytical workflow) |
| Daily Capacity | >5,000 tubes |
| Footprint | ≤2 m² |
| Liquid Handling Range | 1–1,000 µL |
| Configuration | Benchtop, integrated closed extraction zone |
| Safety Systems | Dual HEPA filtration + UV sterilization |
| Sample Input Formats | Single-tube, 10-in-1 pooled, 20-in-1 pooled |
| Reagent Compatibility | Pre-packaged and non-pre-packaged reagents |
| Automation Modules | Tube scanning, auto-cap opening/closing, liquid handling, magnetic bead-based nucleic acid extraction, PCR master mix preparation, PCR assay setup, optional heat-sealing |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Gentier 96E/96R |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Format | Standard 96-Well Plate |
| Throughput | 96 samples per run |
| Interchangeable Block | No |
| Effective Reaction Volume Range | 0–100 µL |
| Heating Rate | ≥6.1 °C/s |
| Cooling Rate | Average ≥2.8 °C/s |
| Temperature Uniformity | ≤±0.1 °C across block |
| Number of Detection Channels | 4 or 6 (model-dependent) |
| Excitation Source | High-Efficiency LED Array |
| Detection Sensitivity | High (capable of detecting ≤10 copies/µL input DNA with standard assay conditions) |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP-aligned data integrity features |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | iGenecase 1600 |
| Instrument Type | Magnetic Bead-Based Purification |
| Automation Level | Dedicated Fully Automatic |
| Batch Sample Capacity | 24 |
| Sample Volume Range | 200–500 µL |
| Sample Processing Time per Batch | 10 minutes |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | GeneFlex 16 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Throughput per Run | 16 samples |
| Sample Volume Range | 20 µL – 1700 µL |
| Consumables | TIANLONG 96-well Deep-Well Plates, 6-tube Strips, and Compatible Stirring Sleeves |
| Cycle Time | 10–60 minutes per run |
| Third-Party Reagent Compatibility | Yes — supports all magnetic bead-based nucleic acid extraction kits |
| Regulatory Compliance | Compliant with Chinese Medical Device Class II registration requirements (No. 2022-3400087), adheres to ISO 13485:2016 quality management system standards for in vitro diagnostic devices |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | Aurora PANA X6 |
| Automation Level | Dedicated Fully Automatic |
| Throughput | 576 samples per batch |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Panall 8000 |
| Instrument Type | Real-Time Quantitative PCR System |
| Sample Throughput | 1–8 samples |
| Modular Exchangeability | Not supported |
| Effective Reaction Volume Range | Max sample volume ≤ 2/3 of tube capacity |
| Heating Rate | Avg ≥ 4.5°C/s |
| Cooling Rate | Avg ≥ 3.5°C/s |
| Temperature Uniformity | ±0.2°C across wells |
| Temperature Accuracy | ≤ ±0.1°C |
| Temperature Control Precision | ≤ ±0.1°C |
| Detection Channels | 4 |
| Light Source | High-Stability LED Array |
| Detection Sensitivity | 99.99% (based on validated assay performance under ISO 13485-controlled manufacturing) |
| Software Compliance | Supports audit trail, user access control, and electronic signature per FDA 21 CFR Part 11 requirements for regulated laboratories |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Model | Gentier 48E / 48R |
| Sample Throughput | 48 wells |
| Interchangeable Modules | No |
| Effective Reaction Volume Range | 0–100 µL |
| Max Heating Rate | ≥8.0 °C/s |
| Max Cooling Rate | ≥6.2 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Well-to-Well Temperature Uniformity | ≤±0.1 °C |
| Detection Channels | 4-channel (Gentier 48E) / 2-channel (Gentier 48R) |
| Excitation Source | High-intensity LED |
| Emission Detection | Photodiode-based fluorescence detection |
| Fluorescence Scan Time | ≤2 s for full 48-well scan (4-color or 2-color) |
| Excitation Wavelengths | Ch1: 465 nm, Ch2: 527 nm, Ch3: 580 nm, Ch4: 632 nm (48E) |
| Emission Wavelengths | Ch1: 510 nm, Ch2: 563 nm, Ch3: 616 nm, Ch4: 664 nm (48E) |
| Linearity (R²) | ≥0.990 |
| Ct Value Reproducibility (CV%) | ≤0.5% |
| Ct Linearity (r) | ≥0.999 |
| Thermal Gradient Support | 35–100 °C, span 1–40 °C |
| Thermal Cycling Range | 0.0–100.0 °C |
| Hot Lid Temperature Range | 40–110 °C |
| Power Supply | AC 220 V (±10%), 50 Hz, 600 VA |
| Dimensions (W×L×H) | 260 × 400 × 260 mm |
| Weight | 11 kg |
| Display | 7-inch full-color capacitive touchscreen |
| Data Storage Capacity | ≤1000 experiment files |
| Software Functions | Absolute quantification, relative quantification, melting curve analysis, high-resolution melting (HRM), SNP genotyping, endpoint fluorescence, isothermal amplification fluorescence analysis |
| Compliance Features | Audit trail support, user access levels, electronic signature readiness (aligned with FDA 21 CFR Part 11 principles), GLP/GMP-compatible data handling protocols |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Gentier 96R |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Format | Standard 96-Well Plate |
| Throughput | 96 samples per run |
| Interchangeable Thermal Block | No |
| Effective Reaction Volume Range | 0–100 µL |
| Maximum Heating Rate | ≥6.1 °C/s |
| Cooling Rate | Average ≥2.8 °C/s |
| Temperature Uniformity | ≤±0.1 °C |
| Temperature Accuracy | ≤±0.1 °C |
| Detection Channels | 4 |
| Light Source | High-Efficiency Long-Life LED |
| Optical Detection Method | Top-Illumination & Top-Scanning with Simultaneous Multi-Channel Per-Well Acquisition |
| Fluorescence Scan Time | ≤7 seconds for full 96-well plate across all 4 channels |
| Dynamic Fluorescence Range | Adjustable per reagent kit |
| Linearity (r) | ≥0.999 |
| Ct Value Reproducibility (CV) | ≤0.5% |
| Supported Assay Types | Absolute Quantification, Relative Quantification, Genotyping (SNP), Melting Curve Analysis, High-Resolution Melting (HRM), Endpoint Fluorescence Detection |
| Software Compliance | FDA 21 CFR Part 11–Ready Audit Trail, User Role-Based Access Control, LIS Integration (CSV/Excel/TXT export, open API), GLP/GMP-aligned data integrity features |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Polaris c1000 |
| Price Range | USD 63,000 – 91,500 (based on EUR/USD exchange parity and typical export pricing) |
| Instrument Type | Mid-Speed Fully Automated Analyzer (400–1000 tests/hour) |
| Reagents | KHB-licensed reagents only |
| Sample Types | Serum, Plasma, Urine, Whole Blood, Cerebrospinal Fluid (CSF) |
| Throughput | Constant-speed 1000 tests/hour |
| ISE module | 600 tests/hour (optional) |
| Brand | Kehua Biosciences (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | ST-960 |
| Detection Method | Absorbance (Photometric) |
| Function Type | Multifunctional |
| Automation Level | Fully Automatic |
| Measurement Modes | Absorbance, Factor Calculation, Standard Concentration, Standard Curve, Single-Threshold, Dual-Threshold, Categorical Classification, Column Subtraction, Point-to-Point |
| Optical System | 8-Channel High-Precision Fiber Optic Path |
| Wavelength Range | 400–1000 nm |
| Absorbance Range | 0.000–4.500 Abs |
| Linearity Range | 0.000–3.000 Abs |
| Wavelength Accuracy | ±5 nm (at center wavelength) |
| Detection Speed | <5 seconds per 96-well plate (single or dual wavelength) |
| Resolution | 0.001 Abs |
| Light Source | Long-Life LED Cold Light Source |
| Display | 7-inch True-Color Touchscreen (840 × 480 resolution) |
| Filter Positions | 8 positions |
| Data Storage | Internal high-capacity memory |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Gentier Mini / Mini+ |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 16 wells |
| Interchangeable Thermal Block | No |
| Effective Reaction Volume Range | 0–100 µL |
| Max Heating Rate | 5.0 °C/s |
| Max Cooling Rate | 4.0 °C/s |
| Temperature Accuracy | ≤ ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Detection Channels | 4 |
| Light Source | High-Efficiency LED |
| Sensitivity Mode | High-Sensitivity Detection |
| Software Functions | Absolute Quantification, Relative Quantification, Melting Curve Analysis, High-Resolution Melting (HRM), Genotyping, Endpoint Fluorescence Analysis |
| Connectivity | Ethernet, USB, Wi-Fi |
| Display | 7-inch Full-Color Capacitive LCD Touchscreen |
| Dimensions | 205 × 156 × 153 mm (L×W×H) |
| Weight | 3.2 kg |
| Data Storage | ≥1,000 runs onboard |
| Power Failure Recovery | Yes — resumes interrupted runs upon reboot |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Model | Gentier X3 |
| Sample Throughput | 96-well (3 × 32-well independent modules) |
| Effective Reaction Volume Range | 0–100 µL |
| Max Heating Rate | ≥6.2 °C/s |
| Avg Heating Rate | ≥4.5 °C/s |
| Avg Cooling Rate | ≥3.5 °C/s |
| Max Cooling Rate | ≥5.0 °C/s |
| Temperature Accuracy | ≤±0.1 °C |
| Temperature Uniformity | ±0.2 °C |
| Light Source | High-Efficiency LED Array |
| Fluorescence Detection Channels | 6 |
| Fluorescence Scan Time per Module | ≤2 s |
| Optical Linearity | r ≥ 0.990 |
| Inter-Run CV | ≤1% |
| Power Supply | AC 220 V, 50 Hz, 1200 VA |
| Dimensions (W×D×H) | 380 × 410 × 395 mm |
| Weight | 34 kg |
| Onboard Display | 13.3″ Full-Color Touchscreen (Adjustable Tilt) |
| Standalone Operation | Supported |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP data integrity features |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Genrich 24 |
| Pricing | Upon Request |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Npex 192 |
| Price | USD 28,000 (FOB) |
| Throughput | 1–192 samples per run |
| Sample Volume Range | 30–1000 µL |
| Magnetic Bead Carryover | ≤1% |
| Temperature Control Range (Lysis & Elution) | 30–120 °C |
| Oscillation Modes | 8 adjustable settings |
| Supported Chemistry | Magnetic bead-based kits (96-test format per deep-well plate) |
| Display | 7-inch color capacitive touchscreen |
| Onboard Storage | >10,000 protocols |
| Dimensions (L×W×H) | 710 × 535 × 515 mm |
| Weight | 55 kg |
| Power Supply | AC 220 V, 50 Hz |
| Operating Environment | 10–30 °C, ≤80% RH |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Polaris c2000 |
| Price Range | USD 95,000–136,000 (FOB) |
| Instrument Type | High-throughput Fully Automated Analyzer (1000–2000 tests/hour) |
| Reagents | KHB-licensed in vitro diagnostic reagents only |
| Sample Types | Serum, Plasma, Urine, Whole Blood, Cerebrospinal Fluid (CSF) |
| Throughput | Constant-speed mode: 2000 tests/hour |
| Stat Emergency (SE) mode | 600 tests/hour (optional) |
| Brand | Waters & KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Ultra-High Performance Liquid Chromatography–Triple Quadrupole Mass Spectrometer (UHPLC-TQMS) |
| Configuration | Integrated UHPLC Platform with Tandem Quadrupole MS Detector |
| Regulatory Context | Designed for GLP/GMP-compliant laboratories and clinical research environments |
| Software Compliance | Supports 21 CFR Part 11–compliant audit trails and electronic signatures |
| Brand | Kehua Bio (KHB) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ZY-1200 |
| Instrument Type | High-throughput Fully Automated Analyzer (1000–2000 tests/hour) |
| Assay Speed | 800 photometric tests/hour (biochemistry), 400 tests/hour (optional ISE module) |
| Minimum Sample Volume | 1.0 µL (0.1 µL increment) |
| Minimum Reagent Volume | 10 µL |
| Minimum Reaction Volume | 90 µL |
| Sample Types | Serum, plasma, whole blood, urine (per reagent package insert) |
| Reagent Compatibility | Kehua Bio–branded IVD reagents only |
| Regulatory Status | NMPA-certified Class II IVD device for clinical use in China |
| Test Menu | ~80 assays available with CE-IVD–marked or NMPA-registered reagents |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer | TIANLONG |
| Country of Origin | China |
| Model | Biolum |
| Detection Range | 0–999,999 RLU |
| Limit of Detection | 1.0 CFU/mL |
| Detection Sensitivity | 1×10⁻¹⁶ mol ATP |
| Display | 3.5-inch color LCD |
| Dimensions (W×D×H) | 70 × 35 × 189 mm |
| Weight | ≤300 g (with battery) |
| Detection Time | 10 s per sample |
| Accuracy | ±5% or ±5 RLU |
| Data Storage | 999 records |
| Battery Life | >10 h continuous operation, >500 h standby |
| Operating Environment | 5–40 °C, 20–85% RH |
| Connectivity | USB 2.0, Bluetooth 4.0 |
| Power | Rechargeable Li-ion battery (Mini-USB charging), optional solar/car charger |
| Swab Compatibility | TIANLONG ATP QuickSwab (liquid-stable, single-use) |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NP968-C |
| Instrument Principle | Magnetic Bead-Based Separation |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–32 samples |
| Sample Volume Range | 30 µL – 1000 µL |
| Consumables | 96-Deep Well Plates, 6-Tube Strips |
| Cycle Time | 30–60 minutes per batch |
| Compatible Sample Types | Animal/plant tissues, whole blood, serum/plasma, saliva, buccal swabs, forensic evidence (e.g., bloodstains, hair follicles), and other clinical or environmental specimens for DNA/RNA isolation |
| Third-Party Reagent Compatibility | Yes — compatible with all standard magnetic bead-based nucleic acid extraction kits |
| Compliance | Designed to meet ISO 13485 requirements for in vitro diagnostic (IVD) manufacturing environments |
| Brand | Kehua Bio (KHB) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZY-680 |
| Instrument Class | Mid-Speed Fully Automated Analyzer (400–1,000 tests/h) |
| Assay Throughput | 680 photometric tests/h (biochemistry), 400 tests/h (ISE module, optional) |
| Sample Types | Serum, plasma, whole blood, urine (per reagent package insert) |
| Reagent Compatibility | Kehua Bio–branded reagents only |
| Wavelength Range | 340–800 nm |
| Optical System | Holographic flat-field concave grating + diode array transient detection |
| Temperature Control | Water-bath incubation at 37.0 ± 0.1 °C with real-time display and out-of-range alarm |
| Cleaning System | Multi-step warm-water cuvette washing, independent polished vortex stirrer, KHB-specific cleaning solution |
| Sample/Reagent Capacity | High-capacity sample and reagent carousels with priority emergency sample insertion, auto-dilution & retest |
| Reagent Cooling | Peltier-based refrigeration (2–8 °C) |
| Reagent Monitoring | Real-time residual volume tracking with test-count estimation |
| Cuvette Design | Optimized geometry with bottom-structured reagent vials for minimized dead volume |
| Brand | Kehua (KHB) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Aurora Flexi96 |
| Pricing | Available Upon Request |
| Brand | TIANLONG |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer | TIANLONG Biotech Co., Ltd. |
| Model | Fascan 48E |
| Instrument Type | Real-Time Fluorescent Quantitative PCR System |
| Sample Throughput | 48 |
| Interchangeable Block | No |
| Temperature Range | 4.0°C – 99.0°C |
| Temperature Accuracy | ≤ ±0.3°C (40.0°C – 99.0°C), ≤ ±1.0°C (4.0°C – 39.9°C) |
| Well-to-Well Temperature Uniformity | CV ≤ 0.5% |
| Detection Channels | 4 |
| Excitation Wavelengths | 470 nm, 523 nm, 571 nm, 630 nm |
| Emission Wavelengths | 525 nm, 564 nm, 612 nm, 670 nm |
| Light Source | High-Brightness Maintenance-Free LED |
| Detector | Photodiode |
| Sensitivity | High (capable of detecting single-copy nucleic acid targets under optimized assay conditions) |
| Data Storage Capacity | ≤ 1000 experiment setup/data files |
| Control Interface | 7-inch full-color touchscreen or PC-based software |
| Dimensions | 400 mm (L) × 260 mm (W) × 260 mm (H) |
| Weight | 11 kg |
| Brand | Kehua Biosciences (KHB) |
|---|---|
| Origin | Shanghai, China |
| Model | ST-36W |
| Instrument Type | Multifunctional Plate Washer |
| Wash Head Configuration | 8-channel or 12-channel |
| Wash Solution & Waste Reservoirs | 2 L each |
| Soaking Time | Programmable |
| Wash Cycles | Adjustable |
| Residual Volume per Well | ≤1 µL |
Show next