- All
- Favorite
- Popular
- Most rated
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PQ LC–PlasmaQuant MS |
| Instrument Type | Triple Quadrupole ICP-MS Coupled with Liquid Chromatography |
| Application Scope | Universal Elemental Speciation |
| Interface Configuration | Integrated LC–ICP-MS Coupling Kit |
| Software Platform | Clarity Chromatography Software (DataApex) + ASpect MS |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready, GLP/GMP-Compatible Data Handling |
| Automation Level | Fully Automated Unattended Operation Support |
| Column Compatibility | Reversed-Phase HPLC, Ion Chromatography (IC), Size-Exclusion Chromatography (SEC) |
| Detection Capability | Sub-ng/kg LODs for As/Cr species |
| Dynamic Range | 11 orders of magnitude (ADD11 digital detector) |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena GmbH (Germany) |
| Model | UVP Biospectrum Advanced 900 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Spectral Sensitivity Range | 405–810 nm |
| Field of View | 33.5 cm × 32 cm |
| Maximum Simultaneous Samples | 10 mice |
| Detector | −100 °C Cooled Back-Illuminated CCD |
| Lens | Fixed-focus f/0.95 lens |
| Integrated Temperature-Controlled Stage | Yes |
| Onboard Isoflurane Anesthesia Delivery | Yes |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures |
| Filter Customization | User-selectable excitation/emission filter sets |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biometra TRobot II |
| Instrument Type | Fast-cycle PCR System |
| Sample Throughput | 96-well or 384-well format |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PlasmaQuant MS |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | Not Specified |
| Mass Resolution (Unit Mass Resolution, amu) | Not Specified |
| Detection Limit (ng·L⁻¹) | Not Specified |
| Sensitivity (Mcps/mg·L⁻¹) | Not Specified |
| Short-Term Stability (RSD) | Not Specified |
| Long-Term Stability (RSD) | Not Specified |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWER3 G IVD |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | P25 / P25T |
| Pricing | Available Upon Request |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Country of Origin | Imported |
| Model | multi N/C Pharma HT |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared Absorption (NDIR) for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion at up to 1000 °C |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | <3% RSD |
| Detection Limit | 4 ppb C |
| Resolution | 0.001 ppb C |
| Repeatability | ±3% RSD |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena GmbH |
| Country of Origin | Imported |
| Model | UVP ChemSolo Auto |
| Pixel Size | 3.76 µm × 3.76 µm |
| Sensor Dimensions | 11.3 mm × 11.3 mm |
| Dynamic Range | 4.8 OD |
| Quantum Efficiency | 85% |
| Read Noise | 1.5 e⁻ |
| Dark Current | 0.0005 e⁻/p/s |
| Sensor Type | sCMOS (9 MP) |
| Binning Options | 1×1 to 8×8 |
| Compatible Light Sources | Long-life cold-cathode UV transilluminator (20-year lifespan) |
| Supported Image Formats | JPEG, BMP, TIFF |
| Applications | Nucleic Acid Imaging, Protein Gel Imaging, Chemiluminescent Western Blot Detection |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Maxi |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICprep |
| Measurement Elements | F, Cl, Br, I, S |
| Analysis Time | 3–4 min per sample |
| Sample Introduction | Up to 100 µL for liquids, up to 110 mg for solids |
| Combustion Temperature | Up to 1100 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Imported Instrument |
| Model | SPECORD 210 PLUS |
| Optical Design | Double-Beam |
| Detector | Peltier-Cooled CCD Array |
| Wavelength Range | 185–1100 nm |
| Spectral Bandwidth | 0.2, 0.5, 1, 2, and 4 nm (5-step adjustable) |
| Wavelength Accuracy | < ±0.1 nm (entire range) |
| Stray Light | < 0.005% at 340 nm (NaNO₂) |
| Photometric Range | –5 to +5 A |
| Baseline Stability | ≤ 0.0001 A (RMS) |
| Long-Term Drift | ≤ 0.0005 A/h |
| Scan Speed | Up to 12,000 nm/min |
| Wavelength Reproducibility | < ±0.01 nm |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Gradient PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Gradient Configuration | 12-column linear or randomized gradient profiles |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 96SG |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Optional Oxidation | Dual-Wavelength High-Intensity UV Photolysis (for wet chemical oxidation) |
| Detection Modules | NDIR for TOC/TC/TIC/NPOC/POC |
| Sample Introduction | Ceramic Valve-Based Loop Injection System |
| Sample Compatibility | Suspended-solids-rich wastewater, high-salinity matrices, ultrapure water, and solid samples (with optional solid module) |
| Automation Level | Fully Modular, Configurable for Unattended Operation |
| Compliance Support | Designed for GLP/GMP environments |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fastblot B43 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Fast PCR Cycler |
| Sample Capacity | 96-well (0.2 mL tubes, 96-well plates, or 12×8 strip tubes) |
| Max Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.2 °C |
| Gradient Span | 0.1–30.0 °C (linear, per column) |
| Gradient Range | 20–99 °C |
| Block Temp Range | 3–99 °C |
| Lid Temp Range | 30–110 °C |
| Display | 7″ capacitive color touchscreen |
| Noise Level | ≤45 dB(A) |
| Power Consumption | 850 W |
| Dimensions (W×H×D) | 277 × 264 × 457 mm |
| Weight | 15 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Country of Origin | Imported |
| Model | SELMA 96 |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Models | Eco-Mini, Eco-Maxi |
| Pricing | Upon Request |
| Gel Dimensions (Eco-Mini) | 9.4 × 8.0 cm |
| Gel Dimensions (Eco-Maxi) | 19.4 × 18.5 cm |
| Glass Plate Dimensions (Eco-Mini) | 11.0 × 10.0 cm |
| Glass Plate Dimensions (Eco-Maxi) | 21.0 × 20.0 cm |
| Max. Gels per Run | 2 |
| Comb Thickness Options | 0.75 mm, 1.0 mm, 1.5 mm |
| Comb Tooth Counts | 9–30 (Eco-Mini), 12–60 (Eco-Maxi) |
| Sample Capacity | Up to 30 wells (Eco-Mini), up to 60 wells (Eco-Maxi) |
| Well Volume Range | 15–165 µL |
| Buffer Volume (Eco-Mini) | 1580 mL (electrophoresis), 2180 mL (blotting) |
| Buffer Volume (Eco-Maxi) | 5400 mL (electrophoresis), 6100 mL (blotting) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Category | Imported |
| Models | Compact XS, Compact S, Compact M, Compact L, Compact XL |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Country of Origin | Germany |
| Model | Cybi-Well Vario |
| Pipetting Heads | 9 interchangeable heads (96-channel, 384-channel, 1536-channel, capillary) |
| Volume Range | 25 nL – 250 µL (wet & dry) |
| Precision | CV ≤ 1–7% depending on volume and head |
| Plate Formats Supported | 96-, 384-, and 1536-well microplates (shallow & deep well) |
| Carrier Options | 3-, 4-, 5-, or 10-plate carriers |
| Tip Types | Disposable plastic tips, ceramic tips, glass capillaries |
| Software | CyBi-Composer with auto-head recognition and GLP-compliant audit trail |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH & Co. KG |
| Product Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.03 ppb – 10,000 ppm C |
| Repeatability | <1% RSD |
| Compliance | ASTM D5905, ISO 8245, USP <643>, EP 2.2.44, DIN 38409-H41 |
| Software | TOC-Control v4.x with 21 CFR Part 11 compliance options |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Type | Full-Spectrum Simultaneous ICP-OES |
| Detection Limit (Zn at 213.856 nm) | 0.06 ppb |
| Precision (RSD) | ≤0.5% |
| Long-Term Stability (RSD, 4h) | ≤1.5% |
| Wavelength Range | 160–900 nm |
| Optical Resolution | 0.003 nm (at 200 nm) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Flame and Graphite Furnace AAS |
| Monochromator | Plane Grating |
| Optical System | Dual-Beam with Automatic Switching to Single-Beam |
| Detector | CCD Array (185–900 nm) |
| Background Correction | Automatic Deuterium/Halogen Lamp or Zeeman (software-selectable) |
| Spectral Resolution | ≤ 0.1 nm |
| Sensitivity | ≥ 0.9 A for 5 mg/L Cu solution (279.5 nm, air-acetylene flame) |
| Precision (RSD) | < 0.5% (n = 10, typical aqueous standards) |
| Detection Limit (Flame Mode) | < 0.005 mg/L Cu |
| Detection Limit (Graphite Furnace Mode) | Sub-pg range for Cd/Pb (e.g., < 3 pg for Cd) |
| Baseline Stability | < 0.002 A/h (typical, 24 h drift monitoring) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Germany |
| Model | SELMA® |
| Type | Benchtop 96/384-Channel Automated Liquid Handler |
| Dimensions (W×H×D) | 307 × 480–520 × 325 mm |
| Weight | 15–20 kg |
| Display | 3.5-inch color touchscreen (Chinese UI supported) |
| Pipetting Accuracy | ≤1% CV (full range), ≤2–3% CV (low-volume ranges, e.g., 0.5–5 µL) |
| Minimum Dispense Volume | 0.5 µL |
| Maximum Dispense Volume | 1000 µL (96-channel), 60 µL (384-channel) |
| Tip Types | Four for 96-channel (25/60/250/1000 µL) |
| Plate Compatibility | Standard 96-well and 384-well microplates, including PCR plates, assay plates, and deep-well blocks |
| Key Functions | Single-/multi-column dispensing, full-plate transfer, serial dilution, plate reformatting (96↔384), bead-based nucleic acid extraction, wall-touch dispensing, tip washing, mixing, and multi-step aspiration/dispensing with air-gap separation |
Show next