- All
- Favorite
- Popular
- Most rated
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena GmbH (Germany) |
| Model | UVP Biospectrum Advanced 900 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Spectral Sensitivity Range | 405–810 nm |
| Field of View | 33.5 cm × 32 cm |
| Maximum Simultaneous Samples | 10 mice |
| Detector | −100 °C Cooled Back-Illuminated CCD |
| Lens | Fixed-focus f/0.95 lens |
| Integrated Temperature-Controlled Stage | Yes |
| Onboard Isoflurane Anesthesia Delivery | Yes |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures |
| Filter Customization | User-selectable excitation/emission filter sets |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Biometra TRobot II |
| Instrument Type | Fast-cycle PCR System |
| Sample Throughput | 96-well or 384-well format |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.5 °C |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWER3 G IVD |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | P25 / P25T |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Maxi |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Gradient PCR Instrument |
| Sample Capacity | 96-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.2 °C |
| Gradient Configuration | 12-column linear or randomized gradient profiles |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Biometra TAdvanced 96SG |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fastblot B43 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Fast PCR Cycler |
| Sample Capacity | 96-well (0.2 mL tubes, 96-well plates, or 12×8 strip tubes) |
| Max Heating Rate | 6.0 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.2 °C |
| Gradient Span | 0.1–30.0 °C (linear, per column) |
| Gradient Range | 20–99 °C |
| Block Temp Range | 3–99 °C |
| Lid Temp Range | 30–110 °C |
| Display | 7″ capacitive color touchscreen |
| Noise Level | ≤45 dB(A) |
| Power Consumption | 850 W |
| Dimensions (W×H×D) | 277 × 264 × 457 mm |
| Weight | 15 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Models | Eco-Mini, Eco-Maxi |
| Pricing | Upon Request |
| Gel Dimensions (Eco-Mini) | 9.4 × 8.0 cm |
| Gel Dimensions (Eco-Maxi) | 19.4 × 18.5 cm |
| Glass Plate Dimensions (Eco-Mini) | 11.0 × 10.0 cm |
| Glass Plate Dimensions (Eco-Maxi) | 21.0 × 20.0 cm |
| Max. Gels per Run | 2 |
| Comb Thickness Options | 0.75 mm, 1.0 mm, 1.5 mm |
| Comb Tooth Counts | 9–30 (Eco-Mini), 12–60 (Eco-Maxi) |
| Sample Capacity | Up to 30 wells (Eco-Mini), up to 60 wells (Eco-Maxi) |
| Well Volume Range | 15–165 µL |
| Buffer Volume (Eco-Mini) | 1580 mL (electrophoresis), 2180 mL (blotting) |
| Buffer Volume (Eco-Maxi) | 5400 mL (electrophoresis), 6100 mL (blotting) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Category | Imported |
| Models | Compact XS, Compact S, Compact M, Compact L, Compact XL |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena |
| Country of Origin | Imported |
| Model | UVP GelSolo |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported |
| Model | qTOWER 2.2 |
| Price | Upon Request |
| Optical Channels | 6 simultaneous detection channels |
| Excitation Sources | 3 high-intensity LEDs (blue, red, white) |
| Detection Technology | Channel-type photomultiplier tube (CPM) |
| Filter Configurations | 10 interchangeable Ex/Em filter sets |
| Sensitivity | 1 nM FAM in 30 µL reaction volume |
| Sample Capacity | 96-well format |
| Max Ramp Rates | 5.5 °C/s (heating), 4.0 °C/s (cooling) |
| Temperature Uniformity | ±0.2 °C at 95 °C |
| Temperature Accuracy | ±0.1 °C |
| Gradient Range | Up to 40 °C |
| Thermal Lid | 110 °C with SPS (Sample Protection System) and auto-adjusting pressure (up to 10 kg/plate) |
| Software | qPCRsoft v4.x for absolute/relative quantification, ΔΔCt, allelic discrimination, PCR efficiency analysis, and FRET applications |
| Interface | USB 2.0 |
| Dimensions (W×H×D) | 275 × 585 × 275 mm |
| Weight | ~25 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Imported Instrument |
| Model | Scandrop |
| Price | Upon Request |
| Optical Principle | Diode Array Spectrophotometry |
| Wavelength Range | 190–720 nm |
| Wavelength Accuracy | ±0.5 nm |
| Photometric Stability | 0.002 A/h |
| Photometric Range | 0.02–300 A (equivalent to 10 mm pathlength) |
| Photometric Accuracy | ±0.02 A (UV), ±0.01 A (VIS) |
| Measurement Time | 1 s per full spectrum |
| Sample Volume (CHIPCUVETTE) | 0.3–4 µL |
| CHIPCUVETTE Pathlengths | 0.1 mm or 1.0 mm |
| Cuvette Mode Sample Volume | ≥1.7 mL |
| Cuvette Pathlength | 10 mm |
| Interfaces | USB, RS-232 |
| Dimensions (W×H×D) | 240 × 170 × 200 mm |
| Weight | 5 kg |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | TS1 / TSC |
| Pricing | Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Maximum Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Excitation Source | 7 high-intensity solid-state LEDs (UV–NIR spectrum) |
| Detection Technology | 8-channel fiber-optic scanning with PMT detector |
| Detection Channels | Configurable 1–6 channels, including dedicated UV and protein-melting filter sets |
| Linear Temperature Gradient | 12-column gradient (spanning up to 40 °C) |
| Thermal Block Material | Gold-plated pure silver |
| Software | qPCRsoft v5.x (MIQE-compliant reporting, audit trail, CFR Part 11-ready configuration options) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Fast PCR Thermal Cycler |
| Model | Biometra TAdvanced 96 SG |
| Sample Capacity | 96-well format (standard 96-well plates, 0.2 mL tubes, or 8-tube strips) |
| Max Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Uniformity | ±0.15 °C |
| Gradient Span | up to 40 °C across 12 columns |
| Gradient Modes | Linear and Random |
| Block Material | Gold-plated pure silver thermal block |
| Heat Lid | High-Performance Smart Lid (HPSL), pressure-regulated, max lid temperature 110 °C |
| User Management | Three-tier Advanced User Management (AUM) with password protection |
| Software Interface | Dual-view program editor (tabular & graphical), intelligent protocol builder, preloaded templates |
| Compliance Features | Built-in self-diagnostic suite with audit-trail-capable log storage, GLP-compliant operation |
| Operating Noise | ≤45 dB(A) |
| Cooling Method | Bottom-intake / rear-exhaust airflow design |
| Touchscreen | Full-color capacitive touchscreen, glove-compatible |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | UVP (a brand of Analytik Jena) |
| Model | UVP GelStudio PLUS Touch |
| Detection Modes | UV transillumination (302 nm), White light reflection, RGB fluorescence excitation (470/530/630 nm), Optional eLite full-spectrum LED excitation (365–740 nm) |
| Camera | Scientific-grade cooled CCD sensor with 16-bit digitization |
| Lens | Motorized f/1.4 macro lens with auto-focus and zoom |
| Safety | Interlocked UV chamber with automatic lamp shutoff, CE/UL certified |
| Compliance | Meets ISO 9001 manufacturing standards |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Fastblot B44 |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Imported |
| Model | UVP PCR Workstation / UVP PCR Enclosure |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tankblot Eco-Mini |
| Pricing | Available Upon Request |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer | analytikjena GmbH |
| Type | Real-Time Fluorescence Quantitative PCR Instrument |
| Sample Capacity | 384-well format |
| Heating Rate | 4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
| Optical Channels | 4–6 configurable |
| Excitation/Detection Filter Sets | 12 interchangeable combinations including FRET-mismatched and protein melting-specific configurations |
| Light Source | RGBW high-intensity LEDs (blue, green, red, white) |
| Detector | High-sensitivity photomultiplier tube (PMT) |
| Detection Method | 16-channel fiber-optic scanning system |
| Dynamic Range | 10 orders of magnitude |
| Reaction Volume | 2–30 µL |
| Heat Lid Temperature Range | 30–110 °C with auto-adjusting contact pressure up to 30 kg/plate |
| Software | Free lifetime-upgradable analysis suite supporting absolute quantification, dual-standard-curve relative quantification, ddCt with amplification efficiency correction, melting curve analysis, SNP/allele discrimination, endpoint analysis, and efficiency calculation |
| Acoustic Noise Level | ≤45 dB(A) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Product Type | Imported Instrument |
| Model | Biometra TRIO 48 |
| Sample Throughput | 144 wells (3 × 48-well blocks) |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.2 °C across block |
| Display | 7-inch full-color capacitive touchscreen |
| Power Recovery | Auto-resume after power interruption |
| Tube Compatibility | Standard 0.2 mL tubes and 8-tube strips |
| Cooling Method | Passive air cooling with bottom intake / rear exhaust airflow |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | qTOWERiris |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Capacity | 96-well format |
| Heating Rate | 8 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Well-to-Well Temperature Uniformity | ±0.15 °C |
Show next