Empowering Scientific Discovery

Analytik Jena (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported
ModelICprep
Measurement ElementsF, Cl, Br, I, S
Analysis Time3–4 min per sample
Sample IntroductionUp to 100 µL for liquids, up to 110 mg for solids
Combustion TemperatureUp to 1100 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ManufacturerAnalytik Jena GmbH & Co. KG
TypeImported Instrument
Modelmulti EA® 5000
Detection PrinciplesChemiluminescence (N), UV Fluorescence or Microcoulometry (S), Microcoulometry (Cl), NDIR (C)
Furnace ConfigurationDual-mode vertical/horizontal high-temperature combustion furnace (up to 1100 °C)
Sample FormsLiquid (1–100 µL), Gas (up to 100 mL), LPG (1–50 µL), Solid (up to 100 mg)
Detection Range0.0x ppm to % level
Automatic Mode RecognitionYes
Flame Monitoring SensorIntegrated real-time combustion state feedback
Gas Pressure Tolerance0.2–0.6 MPa (O₂), with under/over-pressure alarm
CalibrationSingle calibration curve applicable across full dynamic range
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ManufacturerAnalytik Jena GmbH
TypeImported Instrument
Modelmulti EA 4000
Measurement PrincipleInfrared Absorption (CO₂, SO₂, HCl detection)
Heating SystemHigh-Temperature Ceramic Furnace (HTC)
Sample FormSolid and viscous samples
Modular ConfigurationIndependent C, S, Cl analysis modules
ComplianceASTM D4293, ASTM D5178, ISO 20565, DIN 51721, EN 15408, EPA Method 9096A (for AOX), USP <281> (for residual chlorine)
SoftwaremultiWin v5.x with 21 CFR Part 11 compliance options
SafetyIntegrated Self-Check System (SCS), automatic gas leak detection, overpressure protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Modelmulti EA H 5000
Price RangeUSD 68,000 – 109,000
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ManufacturerAnalytik Jena AG
Product TypeImported Instrument
Modelmulti EA 5100
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
ManufacturerAnalytik Jena AG
Product TypeImported Instrument
Modelmulti EA S 5000
Measurement PrincipleInfrared Absorption (for C), Chemiluminescence (for N), UV Fluorescence or Microcoulometric Detection (for S), Microcoulometric Detection (for Cl)
Furnace SystemDual-mode resistive furnace (vertical/horizontal configuration)
Detection Limitppb-level
Measurement Rangeppb to wt%
Accuracy±0.01 ppm
Analysis Time2–4 minutes
Maximum Furnace Temperature1100 °C
Liquid Sample Volume1–100 µL
Gas Sample Volumeup to 100 mL
Solid Sample Massup to 100 mg
LPG Sample Volume1–50 µL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Modelmulti EA 5010
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Origin CategoryImported Instrument
Modelmulti EA 5010
PriceUpon Request
DetectorHiPerSens UV Fluorescence & Chemiluminescence Detector
Measurement Range0.0x ppm to 100% (w/w or v/v)
Sample VolumeLiquids: 50 µL
Gases20 mL
Combustion Furnace TemperatureUp to 1100 °C
ComplianceASTM D5453, D7183, D7039, ISO 20846, ISO 20884, UOP 97, IP 433, IP 541, EN 15486
SoftwaremultiWin v5.x with 21 CFR Part 11 compliance modules
ConnectivityEthernet, LIMS-ready, Remote Web Access via Browser or Mobile App
SafetyAutomated Self-Check, Real-Time Parameter Monitoring, Push Notification Alert System