| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Country of Origin | Imported |
| Model | multi N/C Pharma HT |
| Instrument Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared Absorption (NDIR) for TOC |
| Oxidation Method | High-Temperature Catalytic Combustion at up to 1000 °C |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | <3% RSD |
| Detection Limit | 4 ppb C |
| Resolution | 0.001 ppb C |
| Repeatability | ±3% RSD |
| Compliance | Designed for GLP/GMP environments |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Instrument Type | Laboratory TOC/TNb Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Optional Oxidation | Dual-Wavelength High-Intensity UV Photolysis (for wet chemical oxidation) |
| Detection Modules | NDIR for TOC/TC/TIC/NPOC/POC |
| Sample Introduction | Ceramic Valve-Based Loop Injection System |
| Sample Compatibility | Suspended-solids-rich wastewater, high-salinity matrices, ultrapure water, and solid samples (with optional solid module) |
| Automation Level | Fully Modular, Configurable for Unattended Operation |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH & Co. KG |
| Product Type | Laboratory TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.03 ppb – 10,000 ppm C |
| Repeatability | <1% RSD |
| Compliance | ASTM D5905, ISO 8245, USP <643>, EP 2.2.44, DIN 38409-H41 |
| Software | TOC-Control v4.x with 21 CFR Part 11 compliance options |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C 2100 |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–60,000 ppm C or N |
| Accuracy | ≤ 3.0% RSD @ 100 mg/L TOC |
| Detection Limit | 50 ppb TOC |
| Resolution | 0.001 ppb |
| Repeatability | ≤ 2.0% RSD @ 100 mg/L TOC |
| Compliance | ASTM D7573, ISO 8245, USP <643>, EN 1484, EPA Method 415.3 & 9060A |
| Software | ASpect® TOC/TN Control & Data Management Suite (21 CFR Part 11 compliant) |
| Brand | analytikjena |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | multi N/C X300 |
| Instrument Type | Laboratory-based TOC/TN Analyzer |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | High-Temperature Catalytic Combustion (up to 1000 °C) |
| Measurement Range | 0–30,000 ppm C or N |
| Accuracy | ±2% of reading |
| Resolution | 0.001 ppb |
| Detection Limit | 4 ppb (as C) |
| Repeatability | ≤1% RSD |
| Nitrogen Detection | Chemiluminescence Detector (CLD) and Conductivity Detector (ChD) |
| Calibration | Single-Standard EasyCal™ Protocol |
| Flow Control | VITA™ Variable Intelligent Time-Adaptive Flow Regulation |
| Safety System | SCS™ Self-Checking Safety System |
| Software Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity protocols |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Manufacturer | Analytik Jena AG |
| Country of Origin | Imported |
| Model | multi X 2500 |
| Price | Upon Request |
| Brand | analytik jena |
|---|---|
| Origin | Germany |
| Manufacturer | analytik jena GmbH |
| Product Type | Laboratory TOC/TN Analyzer |
| Model | multi N/C ® Pharma UV |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Wet Oxidation |
| Measurement Range | 0–10,000 ppm C or N |
| Accuracy | ±3% |
| Resolution | 0.001 ppb |
| Detection Limit | 2 ppb |
| Repeatability | <3% |
| Compliance | Designed for USP <643>, EP 2.2.44, JP 17, FDA 21 CFR Part 11, and GMP/GLP environments |