- All
- Favorite
- Popular
- Most rated
| Brand | CHINYEE |
|---|---|
| Origin | Japan |
| Model | NT-6100A |
| Compliance | USP <711>, <724>, <1092> |
| Apparatus Type | Paddle (App. 2) |
| Vessel Capacity | 900–1000 mL |
| Temperature Control Range | 30–45 °C (±0.2 °C stability) |
| Rotation Speed | 25–250 rpm (±1 rpm accuracy) |
| Number of Vessels | 6 |
| Interface | RS-232C, optional USB/Ethernet upgrade |
| Calibration Support | USP Calibrator Tablets (Prednisone, Salicylic Acid), mechanical verification tools included |
| Drive Architecture | Monolithic shaft coupling with one-touch bath cover release |
| Vessel Positioning | Centered alignment via precision-machined guide rails |
| Traceability | Individual serialized vessels, paddles, and shafts |
| Brand | Chinyee |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | APD500A |
| Pricing | Available Upon Request |
| Application | Fuel Oil, Crude Oil Residues, FCC Slurry Oil, Coker Drum Effluents |
| Sample Limitations | Not suitable for samples containing non-toluene-soluble solids (e.g., sludge), high-melting-point paraffins (>50 °C), or natural bitumens |
| Measurement Range | 0.5–15 wt% |
| Repeatability | ±2% RSD |
| Measurement Time | 30 s (excluding sample prep) |
| Optical Method | Dual-wavelength photometry using interference filters |
| Light Source | Tungsten-halogen lamp |
| Wavelengths | 750 nm and 880 nm |
| Detector | Silicon photodiode |
| Interface | RS-232C |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 460 × 165 × 635 mm |
| Weight | 25 kg |
| Output | Integrated thermal printer + RS-232C port |
| Safety Certification | CE-compliant |
| Brand | CHINYEE / J.U.M. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AeroFid° 200 |
| Pricing | Available Upon Request |
| Brand | CHINYEE |
|---|---|
| Origin | Japan |
| Model | RX-620 |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Standards Compliance | ASTM D4294, ISO 8754, JIS K2541, JIS B7995 |
| Sample Types | Kerosene, Naphtha, Diesel, Crude Oil, Heavy Fuel Oil |
| Measurement Range | 0.003–6.00 wt% S |
| Sample Volume | 3–5 mL |
| Detection Limit | 5–200 ppm |
| C/H Ratio Correction | 0.003 wt%/unit C/H ratio (at 1 wt% S) |
| Calibration | Auto 1-, 2-, or 3-point |
| Sample Changer | 12-position turret with acrylic dust cover |
| Detector System | Single reusable PTFE sample cup with polyester film window (sole consumable) |
| X-ray Leakage | ≤0.6 µSv/h at instrument surface |
| Safety | Interlocked mechanical shutter and door sensor |
| Display | 4-line × 20-character LCD |
| Printer | Integrated dot-matrix printer |
| Interface | RS-232C (1 port) |
| Power | DC 12 V (vehicle battery compatible) |
| Weight | 12 kg |
| Enclosure | Integrated console with display, keypad, and printer |
Show next