Beijing Chengyi Hengyi Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
Model3-200
Detection PrincipleFlame Ionization Detection (FID)
Operating Temperature190 °C (heated sample path & detector chamber)
Response Time< 1 s
FuelHydrogen (low-pressure metal-hydride cartridge, 40 h runtime)
Combustion AirIntegrated air generator (no external cylinder required)
Sample Filtration2 µm stainless steel filter (permanent or replaceable)
Filter CleaningAutomated compressed air or nitrogen back-purge (measurement uninterrupted)
ComplianceEPA Method 25A, EN 12619, ISO 8573-1 (gas purity), GLP/GMP-ready data handling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
ModelOVF3000
Detection PrincipleFlame Ionization Detection (FID)
Sensitivity1 ppm full-scale for CH₄
Response Time0.2 s
Measurement Ranges0–10, 0–100, 0–1,000, 0–10,000, 0–100,000 ppm (selectable)
Oven Temperature190 °C
Carrier/Air SupplyIntegrated zero-air generator
Fuel GasHydrogen (stored in low-pressure metal hydride cartridge, >40 h operation per cartridge)
ComplianceBImSchV 2nd, 13th & 17th Ordinances, EN 12619, EN 13526, EPA Method 25A, EPA Method 503
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
ModelOVF3000
Detection PrincipleFlame Ionization Detection (FID)
Operating Temperature180 °C (heated sample path & detector)
Fuel SystemLow-pressure solid-state metal hydride hydrogen storage
Fuel Runtime40–50 h continuous operation
Max Fill Pressure30 bar (430 PSI)
Response Time≤ 0.2 s
Sample FilterFront-panel accessible, tool-free heated filter
Combustion AirIntegrated zero-air generator
Safety FeaturesFlame-out detection with automatic gas shutoff
ComplianceDesigned for EPA Method 25A, ASTM D6348, ISO 8573-5, and EU EN 15267-3 applicable environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
Model109A
Detection PrincipleDual Flame Ionization Detection (FID)
Operating Temperature190 °C (heated sample path, detector chambers, and filter)
Filter MaterialStainless Steel
Filter Pore Size2 µm
Filtration ModeCompressed Air or Nitrogen Back-Pulse Cleaning
Sample Inlet ConfigurationIntegrated Heated Sample Line with Adjustable Backplate Condensation Prevention System
ComplianceEN 14181, EN ISO 14956, EN 12619, EN 13526, EPA Method 25A, US EPA Reference Method 503
Application ScopeContinuous Emission Monitoring (CEM), Stack Gas Analysis, Ambient Air NMHC Quantification, High-Purity Gas Purity Verification
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
Model155-15
Sample Flow Range10–30 mL/min
Operating Temperature180 °C (heated sample path)
Detector TypeFlame Ionization Detector (FID)
ComplianceDesigned for ASTM D5114, ISO 8712, and EPA Method 25A-compliant SHED testing
Power Supply100–240 VAC, 50/60 Hz
Enclosure19″ rack-mountable (5 U) or top-mount configuration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJ.U.M.
OriginGermany
Model3-200
Detection PrincipleFlame Ionization Detection (FID)
Measurement Range0–10 to 0–100,000 ppm (selectable full-scale ranges)
Sensitivity≤1 ppm CH₄ full-scale
Response Time (T₉₀)≤0.2 s
Oven Temperature190 °C
Carrier/Air SupplyIntegrated zero-air generator
ComplianceEN 12619, EN 13526, EPA Method 25A, EPA Method 503, 2nd/13th/17th BImSchV