| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr S5 |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Distillation Time | 1–99 min |
| Repeatability | ≤0.5% CV (RSD ≤1%) |
| Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Voltage | 115–230 V~, 50/60 Hz |
| Cooling Water Flow | ~5 L/min |
| Dimensions (W×H×D) | 410 × 675 × 410 mm |
| Weight | ~36 kg |
| Titration Interface | RS232 |
| Display | LCD |
| Preprogrammed Methods | 100 |
| Compatible with External Titrator | Yes |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr InKjel Series (InKjel1210M, InKjel625P, InKjel1225M, InKjel450P, InKjel475M) |
| Digestion Time Range | 1–199 min |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | >99.5% |
| Power Input | 750–1500 W (adjustable 0–100% in 1% increments) |
| Voltage | 230 VAC / 115 VAC, 50/60 Hz |
| Dimensions (W × D × H) | ≈54 × 44 × 75 cm |
| Weight (incl. reaction tubes) | ≈20 kg |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | MC3000 |
| Instrument Type | Portable |
| Principle | Cold Vapor Atomic Absorption (CVAA) |
| Detection Limit | ≤1 ng/mL |
| Repeatability | ≤3% (CVAA method) |
| Linearity Error | 5% |
| Mercury Vapor Output Range | 15–500 µg/m³ Hg⁰ |
| Calibration Method | NIST-Recommended Mercury Saturated Vapor Pressure Technique |
| Stabilization Time | 30 min |
| Brand | IMT |
|---|---|
| Origin | Germany |
| Model | VSP-4000 |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 200 °C |
| Valve Oven Temperature Range | Ambient to 200 °C |
| Quantitative Loop Volume | 1 mL |
| Sample Capacity | 80 positions |
| Vial Format | 20 mL |
| Trap Configuration | Single Mikro-packed 1/16″ trap |
| Trap Cooling | Peltier-cooled cold trap at −35 °C |
| Detection Limit | ≤0.1 ppt (for selected VOCs) |
| Thermal Desorption Max Temp | Up to 280 °C (field-upgradable) |
| Optional Features | Internal Standard Addition Module, Split Flow up to 50 mL/min, Foam Sensor, Integrated Pressure & Mass Flow Control |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | 850-011-100706 |
| Material | Perfluoroalkoxy (PFA) |
| Configuration | Dual-channel nebulizer spray chamber assembly with detachable O-ring sealed end cap, integrated make-up gas port, 6 mm OD nebulizer inlet, PFA drain connector kit, quartz torch, PFA injection tube, support stand, and pre-cleaned components (pre-rinsed in high-purity HNO₃/HF) |
| Compliance | Compatible with Thermo Scientific Element 2 HR-ICP-MS and Neptune MC-ICP-MS platforms |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | 3000XS |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤0.1 µg/m³ |
| Repeatability | ≤1.0% |
| Linearity Error | ±1% |
| Wavelength | 253.7 nm |
| Light Source | Electrodeless Discharge Lamp (EDL) |
| Response Time (99% signal) | 1 s |
| Sensitivity | 0.1 µg/m³ (0.01 ppb) |
| Measurement Ranges | 0–100, 0–1000, 0–2000 µg/m³ |
| Data Logger Capacity | 10,000 readings |
| Power Supply | Rechargeable NiMH battery (6 h operation), 12 V DC input, 100–240 V AC (50/60 Hz) |
| Weight | ~5 kg (with battery) |
| Display | Backlit graphical LCD |
| Output Interfaces | USB, RS232, 4–20 mA analog output |
| Housing | Corrosion-resistant ABS with IP65-rated connectors |
| Pump | Maintenance-free diaphragm pump |
| Filter | Integrated particulate filter at probe inlet |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | C-Flow |
| Flow Rates | 50 µL/min and 200 µL/min |
| Material | Perfluoroalkoxy (PFA) |
| Compliance | Compatible with Scott-type spray chambers (35 mm), O-ring-free design |
| Certification | Manufactured under ISO 9001-certified processes, compliant with ASTM D5673 and USP <232>/<233> for trace metal analysis |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Authorization Status | Authorized Distributor |
| Origin Category | Imported |
| Model No. | 850-011-100787 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Behr STI |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Kjeldahl Nitrogen Analyzer System |
| Distillation Time | 1–99 minutes |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Input Voltage | 230 VAC / 115 VAC |
| Frequency | 50/60 Hz |
| Net Weight | ~3.5 kg |
| Dimensions (W × D × H) | ~33 × 20 × 60 cm |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | MMS-NG |
| Instrument Type | Online Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectroscopy (CVAAS) |
| Detection Limit | ≤0.1 ng/m³ |
| Repeatability | ≤1.0% (CVAAS) |
| Linearity Error | ±1% (CVAAS) |
| Measurement Range | 0.001–50 µg/m³ (extendable to 2000 µg/m³ with integrated dilution system) |
| Wavelength | 253.7 nm |
| Sample Inlet Pressure | up to 240 bar (3480 psi) |
| Sampling Points | 2–16 via multiplexed valve manifold |
| Cycle Time | ~3 minutes per point |
| Calibration Method | Saturated mercury vapor generation (NIST-recommended vapor pressure equation) |
| Certifications | ATEX 2G IIC T4 EEx p, IECEx, ISO/DIS 6978-3, ASTM D5954, VDI 2267 Part 8, ISO 6978-1 |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | 3000XS |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | 0.1 µg/m³ |
| Repeatability | ≤3.0% |
| Linearity Error | ±10% |
| Measurement Ranges | 0–100 / 0–1000 / 0–2000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| UV Source | Electrodeless Low-Pressure Mercury Lamp (253.7 nm) |
| Optical Cell | High-Purity Fused Silica |
| Pump Type | Maintenance-Free Diaphragm Pump |
| Battery Life | Up to 6 Hours |
| Data Logging | Integrated Recorder |
| Compliance | Designed for ISO 15202, ASTM D6784, and EPA Method 29–compliant field deployment |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DST-1000 |
| Price | Upon Request |
| Power Supply | 100/115/230 VAC ±10%, 50/60 Hz |
| Power Consumption | 70 W |
| Weight | 4.6 kg (10.15 lbs) |
| Dimensions (L×W×H) | 20 cm × 20 cm × 43 cm (10.15″ × 10.15″ × 16.92″) |
| H with funnel | 51 cm (20.08″) |
| Capacity | 125 mL – 1 L |
| Material Construction | High-Purity PFA (Perfluoroalkoxy alkane) |
| Cooling | Air-cooled, no water required |
| Drainage | Integrated gravity-fed waste channel |
| Temperature Control | Adjustable analog thermostat |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | VM-3000 |
| Instrument Type | Portable |
| Measurement Principle | Cold Vapor Atomic Absorption (CVAAS) |
| Detection Limit | ≤ 0.1 µg/m³ |
| Repeatability | ≤ 1.0% (CVAAS) |
| Linearity Error | ±1% (CVAAS) |
| Wavelength | 253.7 nm |
| UV Source | Electrodeless Low-Pressure Mercury Lamp (EDL) |
| Measurement Cell | Heated Fused Silica |
| Response Time (99%) | < 1 s |
| Measuring Ranges | Range I: 0.1–100 µg/m³ (0.01–10 ppb) |
| Range II | 0–1000 µg/m³ |
| Range III | 0–2000 µg/m³ (0–200 ppb) |
| Sensitivity | 0.1 µg/m³ (0.01 ppb) |
| Alarm | 3-Level Programmable + Status Alarms (Cell Soiling, UV Lamp Exhaustion, Battery Level) |
| Display | Graphical LCD with Backlight |
| Outputs | 4–20 mA, RS-232, Optional Data Logger |
| Power | External 12 V DC or Integrated 12 V Rechargeable Battery (≈5 h runtime) |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | PFA Vial |
| Pricing | Upon Request |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | PFA Bottle |
| Material | Perfluoroalkoxy (PFA) Copolymer |
| Density | 2.13–2.167 g/cm³ |
| Thermal Stability | –270 °C to +260 °C |
| Chemical Resistance | Resistant to HF, aqua regia, concentrated HNO₃/H₂SO₄/HCl, organic solvents, and caustics |
| Compliance | ASTM D4894, ISO 1043-1, USP Class VI biocompatibility certified |
| Manufacturing Standard | Cleanroom-assembled, trace-metal-free (sub-ppt leachables), Class 100/ISO 5 environment |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | AULA-254 Gold |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | < 1 ng/L (with gold amalgamation trap) |
| Repeatability | ≤ 1.0% RSD |
| Linearity Error | ±1% |
| Optical Wavelength | 253.7 nm |
| UV Source | Electrodeless Low-Pressure Mercury Discharge Lamp |
| Sample Introduction | 53-position rotary autosampler |
| Sample Vial | 10 mL glass vials with optional aluminum foil caps |
| Carrier Gas | Argon (4–6 L/h), mass flow controlled |
| Digestion Heater Temperature | 98 °C |
| Optical Cell | Fused silica, 230 mm path length |
| Optical Cell Temperature | 50 °C |
| Measurement Cycle | 60–280 s |
| Software | AULA-WIN (Windows®-based) |
| Power Supply | 115/230 V~, 50–60 Hz, 100 W (120 W with ASD module) |
| Dimensions (W×H×D) | 37 × 38 × 44 cm |
| Footprint Requirement | 50 × 70 cm (W × D) |
| Weight | ~14 kg (without PC) |
| Compliance | EPA Methods 245.1, 245.7, 1631, 7470, 7471A |
| Optional Module | Automated Sample Digestion (ASD) |
| Brand | Mercury Instruments |
|---|---|
| Origin | Germany |
| Model | LabAnalyzer 254 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Wavelength | 254 nm |
| Detection Limit | ≤0.1 µg/L |
| Repeatability | ≤1.0% RSD |
| Linearity Error | ±1.0% |
| Sample Volume | 2–10 mL |
| UV Source | Electrodeless Discharge Lamp (EDL), temperature-stabilized |
| Detector | Temperature-controlled UV-enhanced silicon photodiode |
| Optical Cell | Fused quartz, 23 cm path length, heated to 70 °C |
| Flow Rate | 30 L/h (adjustable) |
| Pump | Long-life diaphragm pump |
| Sensitivity | 5 ng/L (0.05 ng absolute) |
| Linear Range | 0.01–10 µg/L (10 ppt–10 ppb) for 10 mL sample |
| Output Interfaces | 4–20 mA analog, USB/RS-232, parallel printer port |
| Power Supply | 230 VAC, 50–60 Hz (optional 115 VAC) |
| Power Consumption | 35 W |
| Dimensions (main unit) | 45 × 15 × 35 cm (W × H × D) |
| Optical Module | 24 × 48 × 27 cm (W × H × D) |
| Footprint Requirement | ~70 × 50 cm (W × D) |
| Weight | ~10 kg |
| Compliance | DIN 38406-12, EPA Method 7470A & 7471A |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model No. | 850-011-100635 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr Micro Kjeldahl Digestion System K16, K24, K40 |
| Digestion Time Range | 1–99 min |
| Repeatability | ±0.5% |
| Nitrogen Recovery Rate | >99.5% |
| Power Rating | 750–1500 W |
| Sample Capacity | 16 / 24 / 40 positions |
| Digestion Tube Volume | 100 mL |
| Voltage Options | 230 V~ or 115 V~ |
| Housing Material | Corrosion-Resistant Stainless Steel |
| Origin | Germany |
|---|---|
| Type | Portable Mercury Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Gold Amalgamation Preconcentration |
| Detection Limit | ≤0.1 ng/m³ (or 0.5 pg Hg absolute) |
| Repeatability | ≤1.0% RSD |
| Linearity Error | ±1% |
| Sample Volume Range | 0.1–100 L |
| Sampling Cycle | 10 s–15 min |
| Measurement Cycle | 10 s–16 min |
| Measurement Range (10 L sample) | 0.1–2000 ng/m³ |
| Measurement Range (1 L sample) | 1–10,000 ng/m³ |
| Flow Control | Electronic mass flow meter |
| Pump Type | Diaphragm pump with Viton membranes |
| Filter | Disposable 0.45 µm PTFE membrane |
| Light Source | Electrodeless low-pressure mercury lamp (253.7 nm) |
| Data Storage | 10,000 records (~100 days) |
| Interface | USB & RS232 |
| Power Supply | 110/230 V, 50/60 Hz, max. 125 W |
| Dimensions (W×H×D) | 45 × 15 × 35 cm |
| Weight | ~9 kg |
| Operating Temperature | 5–35 °C |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr S1, S2, S3, S4 Kjeldahl Distillation Systems |
| Price Range | USD 13,500–27,000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Distillation Time | 1–99 min |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 750–1500 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Behr K8 / K12 / K20 Standard Kjeldahl Digestion System |
| Price Range | USD 13,500 – 27,000 |
| Instrument Type | Kjeldahl Nitrogen Digestion System |
| Digestion Time Range | 1–99 minutes |
| Repeatability | ±0.5% RSD |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MMS |
| Instrument Type | Online |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤10 ng/m³ (CVAAS) |
| Repeatability | ≤1.0% (CVAAS) |
| Linearity Error | ±1% (CVAAS) |
| Sampling Points | 2–24 |
| Sample Line Purge Flow | 40–80 L/h per line |
| Measurement Cycle | 45 s–99 min (individually configurable per channel) |
| Standard Detector | VM-3000 (Range: 0.1–100, 1–1000, or 1–2000 µg/m³) |
| Trace Detector Option | UT-3000 (Range: 0.01–50 µg/m³) |
| Sample Flow Rate | ~80 L/h |
| Optical Wavelength | 253.7 nm UV absorption |
| Enclosure Rating | IP55 / NEMA 4X |
| Dimensions (W×H×D) | 553×600×500 mm to 800×2000×600 mm (configurable) |
| Weight | 35–175 kg (configuration-dependent) |
| Communication Interfaces | RS-232, Modbus RTU, Ethernet, optional fiber-optic cable |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | Compatible with Agilent 7500 Series |
| Nebulizer Type | PFA Concentric (C-Flow) & Cross-Flow (X-Flow) |
| Nominal Uptake Rate | 200 µL/min (C-Flow), 50 µL/min (C-Flow Low-Flow Option) |
| Material | 100% Perfluoroalkoxy (PFA), O-Ring-Free Construction |
| Torch Interface | Push-Fit Connector for Agilent ICP-MS Torch |
| Compliance | Fully Compatible with ASTM D5673, ISO/IEC 17025 Trace Metal Analysis Protocols, USP <232>/<233> Elemental Impurities Testing |