Add to compare
BrandJASCO
OriginJapan
ModelV-670
Optical DesignSingle-beam
DetectorPhotomultiplier Tube (PMT) for UV-Vis
Wavelength Range190–2700 nm (extendable to 3200 nm)
Spectral Bandwidth0.1, 0.2, 0.5, 1, 2, 5, 10 nm (selectable)
Wavelength Accuracy±0.3 nm (UV-Vis)
Wavelength Repeatability±0.05 nm (UV-Vis)
Stray Light≤0.005% T
AutomationMotorized wavelength scanning and slit control
ComplianceASTM E275, ISO 6247, USP <857>, JIS K 0115
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
ModelV-770
Optical DesignDouble-beam
DetectorPhotomultiplier Tube (PMT) & Peltier-cooled PbS detector
Wavelength Range190–3200 nm
Spectral Bandwidth0–40 nm
Wavelength Accuracy±0.3 nm (UV-Vis), ±1.5 nm (NIR)
Wavelength Repeatability±0.05 nm (UV-Vis), ±0.2 nm (NIR)
Stray Light≤0.005%
AutomationMotorized wavelength scanning and auto-alignment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelV-7000 Series
Optical SystemDouble-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range175–3300 nm
Wavelength Accuracy±0.08 nm
Spectral Bandwidth0–20 nm (variable, motorized slit control)
Stray Light≤0.00007% (at 220 nm, NaI
Photometric Range±8.0 Abs
Resolution0.049 nm (UV-Vis region, using high-resolution grating mode)
SoftwareJASCO Spectra Manager™ (cross-platform, Windows/macOS/Linux compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMVS-5000 Series
Instrument ArchitectureDual-Wavelength
Detector TypePhotomultiplier Tube (PMT)
Wavelength Range200–2700 nm
Automation LevelMotorized Wavelength Scanning
Spectral Bandwidth1–20 nm
Wavelength Accuracy±0.3 nm
Stray Light<0.0001% (at 220 nm, NaI
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
ModelV-700 Series
Optical SystemDouble-beam
DetectorPhotomultiplier Tube (PMT)
Wavelength Range190–3200 nm
Wavelength Accuracy±0.3 nm
Spectral Bandwidth0.1, 0.2, 0.5, 1, 2, 5, 10 nm
Stray Light≤0.005 %
AutomationAutomatic Wavelength Scanning
ComplianceFDA 21 CFR Part 11 (via Spectra Manager CFR Edition)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Instrument ConfigurationDouble-beam
DetectorPhotomultiplier Tube (PMT)
Automation LevelMotorized Wavelength Scanning
Wavelength Range250–2000 nm
Stray Light≤0.003% T
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
ModelV-630 Bio
Optical SystemSingle-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.2 nm
Spectral Bandwidth1 nm
Stray Light≤0.02% T
AutomationMotorized Wavelength Scanning
Sample Volume Requirement (with 8-position micro-volume rotator)4 µL per measurement
Temperature Control OptionPeltier-based electronic thermostat (optional)