BrandJASCO
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLC-4000 Series
Instrument TypeConventional HPLC System
Flow Rate Range0.01–50 mL/min
Maximum Pressure130 MPa
Sample Loop Capacity2 mL (180-position tray)
Injection Volume Range0.1–100 µL
Column Oven Temperature RangeAmbient +10 °C to 200 °C
UV-Vis Wavelength Range190–900 nm
Data Acquisition Rate100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Model8610
Detection Limit1 ppb
Dimensions49.5(W) × 36.8(D) × 34.3(H) cm
Regulatory ComplianceEPA Methods 8010, 8015, 8021
Carrier Gas ControlElectronic Pressure Control (EPC), 0–80 psi programmable at 90 psi/min
Column OvenAmbient to 400 °C, 0.01 °C resolution, ±0.1 °C stability, 19.8 × 19.0 × 7.6 cm internal volume
Detector Options16 configurable detectors, up to 6 simultaneously installed
Injection Modes12 selectable methods, up to 5 concurrently configured
SoftwarePeakSimple v4.x, USB interface, 4-channel data acquisition
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelChiral LC-4000
Instrument TypeConventional HPLC System
Flow Rate Range0.01–10 mL/min
Maximum Pressure70 MPa
Sample Loop Capacity2 mL (180-position tray)
Injection Volume Range0.1–100 µL
Column Oven Temperature Range(Ambient + 10 °C) to 200 °C
UV-Vis Wavelength Range200–460 nm
Data Acquisition Rate100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
ModelSRI-8610C
Instrument TypePortable Gas Chromatograph
Temperature Control Range0–400 °C
Temperature Ramp Rate0.1 °C/min (programmable)
Cool-down Time~15 min (400 °C to ambient)
Carrier Gas Flow ControlElectronically adjustable
Carrier Gas Pressure Control0–80 psi (EPC-programmable)
Injector Maximum Operating Temperature400 °C
Injector Pressure Setpoint Range0–80 psi (programmable)
Injector Total Flow Setpoint RangeAdjustable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJASCO
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelLC-4000
Instrument TypeHigh-Throughput Supercritical Fluid Chromatograph
Flow Rate Range0.5–150.0 mL/min
Maximum Operating Pressure30 MPa
Flow Precision<0.1% RSD
Injection Volume Range0.1–20,000 µL
Injection Positions180
Column Oven Temperature RangeAmbient to 90°C
UV-Vis Detection Wavelength Range190–900 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Model8610C (Routine Configuration)
Instrument TypePortable Gas Chromatograph
Application FieldEnvironmental Monitoring
Oven Temperature Range0–400 °C
Temperature Ramp Rate0.1 °C/min (minimum programmable increment)
Cool-down Time~15 min (from 400 °C to ambient)
Carrier Gas Flow ControlElectronically adjustable
Carrier Gas Pressure Range & Control0–80 psi, program-controlled via EPC
Injector Maximum Operating Temperature400 °C
Injector Pressure Setpoint Range0–80 psi, fully programmable
Injector Total Flow Setpoint RangeElectronically adjustable
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRI
OriginUSA
Model8610C (Pesticide Residue Configuration)
Instrument TypePortable Gas Chromatograph
Temperature Control Range0–400 °C
Temperature Ramp Rate0.1 °C/min (minimum programmable increment)
Cooling Time~15 min (from 400 °C to ambient)
Carrier Gas Flow RangeAdjustable (EPC-controlled)
Carrier Gas Pressure Range0–80 psi (programmable EPC)
Injector Maximum Temperature400 °C
Injector Pressure Setpoint Range0–80 psi (programmed)
Injector Total Flow Setpoint RangeAdjustable