- All
- Favorite
- Popular
- Most rated
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-EzPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Temperature Control Range | 15–40 °C, Accuracy: ±0.1 °C, Stability: ±0.01 °C |
| Detection Limit | 5 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 150 ng/mL (for 100–1000 kDa) to 5 µg/mL (for 4–20 kDa) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Nano XploRA |
| Instrument Type | Confocal Micro-Raman Spectrometer with Integrated Atomic Force Microscopy (AFM) |
| Optical Coupling Options | Top, Side, and Bottom Illumination Paths |
| Objective Compatibility | Supports High-NA ×100 Objectives for All Coupling Modes |
| TERS-Ready Architecture | Fully Optimized for Tip-Enhanced Raman Scattering |
| AFM Feedback | Automatic Laser Alignment via Photodiode-Based Optical Lever System |
| Scan Head | High-Frequency, Low-Noise Piezoelectric Scanner |
| Software Integration | Unified Control Suite for Synchronized AFM Topography, Mechanical Mapping, and Point/Line/Area Raman Spectroscopy |
| Compliance Framework | Designed to Support GLP/GMP workflows with audit-trail-capable data logging (21 CFR Part 11-ready configuration available) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-4000 Series |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.01–50 mL/min |
| Maximum Pressure | 130 MPa |
| Sample Loop Capacity | 2 mL (180-position tray) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | Ambient +10 °C to 200 °C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | DynaMyc |
| Detection Principle | Time-Correlated Single Photon Counting (TCSPC) |
| Lifetime Range | 100 ps – 10 µs |
| Spectral Detection Range | 185–650 nm / 300–850 nm (with TBX fast detector) |
| Spatial Resolution | 0.5 µm |
| Scan Stage Travel | 75 × 50 mm |
| Laser Source Options | Pulsed diode lasers (370–980 nm), DeltaDiode series, repetition rate up to 100 MHz, CW/pulsed mode selectable |
| Excitation Filtering | Motorized filter wheel with dichroic mirrors and pinholes (100–1000 µm) |
| Data Acquisition Modes | Single-point, multi-point, FLIM mapping |
| Software | DataStation (instrument control), DAS6 (lifetime decay analysis & deconvolution) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | HORIBA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FluoroCube |
| Price Range | USD 65,000 – 130,000 (FOB) |
| Dispersive Element | Grating |
| Slit Width (Spectral Bandpass) | 1–32 nm |
| Spectral Resolution | 1 nm |
| Sensitivity | >3000:1 (Signal-to-Noise Ratio) |
| Wavelength Accuracy | ±0.05 nm |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610 |
| Detection Limit | 1 ppb |
| Dimensions | 49.5(W) × 36.8(D) × 34.3(H) cm |
| Regulatory Compliance | EPA Methods 8010, 8015, 8021 |
| Carrier Gas Control | Electronic Pressure Control (EPC), 0–80 psi programmable at 90 psi/min |
| Column Oven | Ambient to 400 °C, 0.01 °C resolution, ±0.1 °C stability, 19.8 × 19.0 × 7.6 cm internal volume |
| Detector Options | 16 configurable detectors, up to 6 simultaneously installed |
| Injection Modes | 12 selectable methods, up to 5 concurrently configured |
| Software | PeakSimple v4.x, USB interface, 4-channel data acquisition |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | SPRi-OpenPlex |
| Sample Volume | 200 µL (standard), optional 100/250/500 µL |
| Detection Limit | 10 pg/mm² |
| Minimum Analyte MW | >240 Da |
| Sample Concentration Range | 300 ng/mL (for 100–1000 kDa) to 10 µg/mL (for 4–20 kDa) |
| Temperature Control | Not specified in input |
| Compliance | CE-marked, compatible with GLP/GMP workflows requiring audit trails and instrument qualification |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chiral LC-4000 |
| Instrument Type | Conventional HPLC System |
| Flow Rate Range | 0.01–10 mL/min |
| Maximum Pressure | 70 MPa |
| Sample Loop Capacity | 2 mL (180-position tray) |
| Injection Volume Range | 0.1–100 µL |
| Column Oven Temperature Range | (Ambient + 10 °C) to 200 °C |
| UV-Vis Wavelength Range | 200–460 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | HE |
| Instrument Type | Portable / Handheld Raman Spectrometer |
| Spectral Range | 200–3200 cm⁻¹ |
| Spectral Resolution | < 5 cm⁻¹ (typical, dependent on grating and slit configuration) |
| Spatial Resolution | Diffraction-limited, down to ~1 µm (with 50× long-working-distance objective and confocal option) |
| Minimum Wavenumber | 200 cm⁻¹ |
| Spectral Reproducibility | < ±0.2 cm⁻¹ (over 8-hour operation, temperature-stabilized optics) |
| Detector | 1024 × 256 pixel CCD, MPP mode |
| Cooling | Peltier-cooled to −70 °C (air-cooled, no water required) |
| Read Noise | < 8 e⁻/pixel |
| Dark Current | < 0.01 e⁻/pixel/s |
| Laser Wavelength Options | 532 nm, 633 nm, 785 nm |
| Laser Power Range | 80–300+ mW (adjustable per application) |
| Fiber Probe Support | Up to 4 simultaneous SuperHead™ probes |
| Software | LabSpec 6 (Windows-compatible, FDA 21 CFR Part 11–ready audit trail & user access control) |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | SRI-8610C |
| Instrument Type | Portable Gas Chromatograph |
| Temperature Control Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (programmable) |
| Cool-down Time | ~15 min (400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Control | 0–80 psi (EPC-programmable) |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi (programmable) |
| Injector Total Flow Setpoint Range | Adjustable |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LC-4000 |
| Instrument Type | High-Throughput Supercritical Fluid Chromatograph |
| Flow Rate Range | 0.5–150.0 mL/min |
| Maximum Operating Pressure | 30 MPa |
| Flow Precision | <0.1% RSD |
| Injection Volume Range | 0.1–20,000 µL |
| Injection Positions | 180 |
| Column Oven Temperature Range | Ambient to 90°C |
| UV-Vis Detection Wavelength Range | 190–900 nm |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-4000, FT/IR-6000 Series |
| Instrument Type | Laboratory Fourier Transform Infrared (FTIR) Spectrometer |
| Wavenumber Range | 7800–400 cm⁻¹ |
| Spectral Resolution | 0.4 cm⁻¹ |
| Signal-to-Noise Ratio (S/N) | 55,000:1 (at 4 cm⁻¹, 1 min scan, MCT detector) |
| Sample Compatibility | Up to 300 mm (12″) silicon wafers |
| Measurement Modes | Specular reflectance, transmission, and attenuated total reflectance (ATR) with wafer-specific accessories |
| Compliance | JEITA RC-2001, JEIDA-6301, SEMI F39, ASTM F1597, ISO 14644-1 (cleanroom-compatible operation) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | J-1500 |
| Instrument Type | Circular Dichroism (CD) Spectrometer |
| Wavelength Range | 163–950 nm (extendable to 1600 nm) |
| Standard Measurement Modes | CD, LD, UV-Vis |
| Optical System | Dual Photoelastic Modulator (PEM) with Vacuum UV-optimized Polarization Optics |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Profiler 2 |
| Excitation Source | Pulsed RF Glow Discharge |
| Depth Range | 1 nm – 200 µm |
| Depth Resolution | < 1 nm |
| Elemental Coverage | ≥70 elements including C, H, O, N, Cl |
| Spectral Range | 110–800 nm |
| Spectral Resolution (Polyscan) | 18–25 pm |
| Detector | High Dynamic Detector (HDD), dynamic range 5×10¹⁰ |
| Compliance | ISO 14707, ISO 16962 |
| Software | Quantum v5.x with GLP/GMP audit trail support |
| Optional Configuration | Monochromator for n+1 flexible channel selection |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | MicOS |
| Application | Fluorescence Spectroscopy |
| Grating Configuration | Triple-grating imaging spectrometer with motorized grating turret |
| Spectral Range | 200 nm – 1600 nm |
| Imaging Capability | Integrated digital camera for real-time sample visualization |
| Microscope Orientation | Inverted or side-entry configuration (compatible with cryostats) |
| Excitation Laser Compatibility | 325 nm, 405 nm, 488 nm, 532 nm, 633 nm, 785 nm |
| Objective Options | 10×, 50×, 100× (UV-VIS-NIR optimized) |
| Spot Size | down to <10 µm (dependent on objective and wavelength) |
| Detector Options | Back-illuminated CCD (200–1050 nm), InGaAs array (800–1600 nm), UV-enhanced CCD (190–1100 nm), selectable per spectral segment |
| Software Platform | LabSpec 6 (FDA 21 CFR Part 11 compliant audit trail, GLP/GMP-ready) |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | VHR640 / VHR1000 |
| Focal Length | 640 mm / 1000 mm |
| Input/Output Ports | Dual entrance & dual exit |
| Grating Mount | Turret with dual gratings |
| Optical Design | Czerny–Turner |
| Wavelength Range | 100 nm – 15 µm (grating-dependent) |
| Spectral Resolution (10 µm slit) | 0.016 nm (VHR640) / 0.010 nm (VHR1000) |
| Wavelength Accuracy | ±0.03 nm |
| Wavelength Repeatability | ±0.015 nm |
| Scanning Speed | >300 nm/s |
| Spectral Dispersion | 1.2 nm/mm (VHR640) / 0.8 nm/mm (VHR1000) |
| Entrance F/# | f/5.4 (VHR640) / f/9.0 (VHR1000) |
| Grating Size (single-grating mode) | 110 mm × 110 mm |
| Grating Size (dual-grating mode) | 80 mm × 110 mm |
| Slit Range | 0–2 mm (micrometer-adjustable) |
| Vacuum Compatibility | <1×10⁻⁵ mbar |
| Vacuum Flanges | DN25 KF (pump & gauge), DN63 LF (slit), DN100 LF (CCD), PC interface (RS232 to USB) |
| Dimensions (L×W×H) | 740×350×350 mm (VHR640) / 1160×430×350 mm (VHR1000) |
| Mass | 65 kg (VHR640) / 70 kg (VHR1000) |
| Optional Accessories | Pre-mirror chamber (two toroidal mirrors), Post-mirror chamber (two toroidal mirrors), Sample chamber (up to four 25 mm Ø samples), Polarizer inserts, 4 K cryostat, Vacuum pump |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Nanolog® |
| Excitation Source | 450 W continuous xenon lamp |
| Wavelength Range | UV–NIR (200–1700 nm, extendable to ~3 µm) |
| Spectral Resolution | 0.06 nm |
| Slit Width (Spectral Bandpass) | 0–20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Sensitivity | >20,000:1 (at 1,550 nm, using liquid-nitrogen-cooled InGaAs array) |
| Detection Modes | Steady-state, time-resolved (TCSPC), and combined steady-state/time-resolved spectroscopy |
| Detector Options | PMT (UV–NIR), Symphony II InGaAs array (800–1700 nm |
| Lifetime Range | Fluorescence 100 ps–1 ms |
| Software | NanoSizer® for SWNT characterization (diameter distribution, FRET analysis), FluoroLog®-based acquisition and analysis suite |
| Compliance | Fully compatible with GLP/GMP data integrity requirements |
| Brand | HORIBA |
|---|---|
| Origin | Canada |
| Model | QuantaMaster 8000 |
| Wavelength Accuracy | ±0.3 nm |
| Spectral Resolution | 0.1 nm |
| Slit Width (Spectral Bandpass) | 0–30 µm |
| Sensitivity | >30,000:1 (Water Raman SNR) |
| Dispersive Element | Grating |
| Pulse Excitation Capability | Up to 100 MHz |
| NIR Phosphorescence Lifetime Range | Up to 5500 nm |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | FT/IR-4000, FT/IR-6000 |
| Instrument Type | Laboratory Benchtop FTIR |
| Wavenumber Range | 25,000–10 cm⁻¹ (extended options available) |
| Spectral Resolution | 0.7–0.07 cm⁻¹ |
| Scan Speed | 20 Hz |
| Signal-to-Noise Ratio | 25,000:1 to 55,000:1 |
| A/D Converter | 24-bit |
| Interferometer | Corner-Cube Retroreflector with Real-Time DSP Mirror Control |
| Optical Stability | Active Beam Alignment Compensation |
| Compatibility | Integrated with JASCO IR Microscopes (e.g., IRT-5200, IRT-7200) |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CPL-300 |
| Pricing | Upon Request |
| Brand | JASCO |
|---|---|
| Origin | Japan |
| Model | V-670 |
| Optical Design | Single-beam |
| Detector | Photomultiplier Tube (PMT) for UV-Vis |
| Wavelength Range | 190–2700 nm (extendable to 3200 nm) |
| Spectral Bandwidth | 0.1, 0.2, 0.5, 1, 2, 5, 10 nm (selectable) |
| Wavelength Accuracy | ±0.3 nm (UV-Vis) |
| Wavelength Repeatability | ±0.05 nm (UV-Vis) |
| Stray Light | ≤0.005% T |
| Automation | Motorized wavelength scanning and slit control |
| Compliance | ASTM E275, ISO 6247, USP <857>, JIS K 0115 |
| Brand | SRI |
|---|---|
| Origin | USA |
| Model | 8610C (Routine Configuration) |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Environmental Monitoring |
| Oven Temperature Range | 0–400 °C |
| Temperature Ramp Rate | 0.1 °C/min (minimum programmable increment) |
| Cool-down Time | ~15 min (from 400 °C to ambient) |
| Carrier Gas Flow Control | Electronically adjustable |
| Carrier Gas Pressure Range & Control | 0–80 psi, program-controlled via EPC |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setpoint Range | 0–80 psi, fully programmable |
| Injector Total Flow Setpoint Range | Electronically adjustable |
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Model | Symphony CCD |
| Cooling | Liquid Nitrogen |
| Sensor Architecture | Front-Illuminated (FI) / Back-Illuminated (BI) / Deep-Depletion (DD) |
| Resolution Options | 1024×256, 2048×512 |
| Pixel Types | UV-Enhanced, Vis-Enhanced, Open Electrode |
| ADC | 16-bit, 20 kHz – 1 MHz readout |
| Interface | Gigabit Ethernet |
| Onboard Memory | Yes |
| Software Control | SynerJY, LabVIEW VI |
| Compliance | Designed for GLP/GMP-aligned spectroscopic workflows per ISO/IEC 17025 and ASTM E131–22 guidance |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | Ultima Expert |
| Instrument Type | Sequential Scanning ICP-OES |
| Detection Limit | Not Specified |
| Repeatability | ≤1% RSD |
| Stability | ≤2% RSD |
| Wavelength Range | 160–800 nm |
| Optical Resolution | ≤0.005 nm (5 pm) |
| Detector | High-Density Diode (HDD) Array |
| Grating Options | 2400 g/mm holographic grating (≤5 pm @ 120–320 nm |
| Grating Size | 110 × 110 mm ion-etched holographic grating |
| Stray Light Level | <1 × 10⁻⁷ |
| Monochromator | Czerny-Turner with 1 m focal length |
| Plasma Observation | Vertical torch with side-on viewing geometry |
Show next