| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-TCR1873 |
| Heating Method | Electric Furnace |
| Heating Power | <1400 W |
| Temperature Control Range | 0–520 °C |
| Temperature Control Accuracy | ±5 °C |
| Total Power Consumption | ≤2000 W |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 345 mm × 345 mm × 381 mm |
| Net Weight | 25 kg |
| Compliant Standard | SH/T 0170 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-WSAA1835 |
| Power Consumption | 1200 W |
| pH Measurement Range | 0.00–14.00 |
| pH Accuracy | ±0.02 pH |
| pH Resolution | 0.01 pH |
| Repeatability | ≤1% |
| Stability | ±1% F.S. / 4 h |
| Response Time (T90) | <1 min at 25 °C |
| Temperature Control Range | Ambient to 100 °C |
| Brand | Spectra Invent / Chinainvent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-ARV1866 |
| Price Range | USD 1,400 – 14,000 |
| Temperature Control Range | Ambient to 99.9°C |
| Temperature Accuracy | ±0.3°C (bath), ±1.0°C (air) |
| Pressure Regulation Range | 0–98 kPa |
| Timing Accuracy | ±1 s |
| Display | LCD |
| Ambient Operating Conditions | 5–40°C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | 1000 W |
| Dimensions | 560 × 350 × 490 mm |
| Weight | 24 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-WR1847A |
| Price Range | USD 1,400 – 14,000 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-960A |
| Price | Upon Request |
| Laser Wavelength | 785 ± 0.5 nm |
| Wavenumber Range | 200–4000 cm⁻¹ |
| Spectral Resolution | 7–10 cm⁻¹ |
| Operating Temperature | −5 to 50 °C |
| Touchscreen | 5.5″ capacitive LCD (1920 × 1080) |
| Dimensions | 172 × 85 × 30 mm |
| Weight | 0.45 kg |
| IP Rating | IP67 |
| Battery Life | ≥ 4 h (Li-ion) |
| Connectivity | Wi-Fi, Bluetooth 5.0, 4G LTE, GPS, GPRS, GSM, USB-C |
| Camera | Dual-module (13 MP + 8 MP), barcode scanning capable |
| Reporting | PDF export with three-tier color-coded result classification |
| Database | Preloaded library of >3000 chemical spectra |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-FPP1220AS |
| Power Consumption | <300 W |
| Temperature Control Range | Ambient to –70 °C |
| Measurement Range | Ambient to –60 °C |
| Accuracy | ±1 °C |
| Cooling Rate | ΔT >15 °C in 10 min |
| Sample Capacity | 2 tubes simultaneously |
| Resolution | 0.1 °C |
| Display | LCD touchscreen |
| Printer | Thermal printer, 36-character Chinese/English output |
| Ambient Operating Conditions | 5–40 °C, ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 600 × 580 × 825 mm |
| Net Weight | 50 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-FPP1200 |
| Price Range | USD 1,400 – 14,000 |
| Power Consumption | ≤1500 W |
| Temperature Resolution | 0.1 °C |
| Temperature Range | −70 °C to +15 °C |
| Cooling Method | Compressor-based refrigeration |
| Bath Configuration | Dual-bath single-chamber isothermal system |
| Timing Resolution | 0.1 s (max 60.0 s) |
| Temperature Sensor | PT100 platinum resistance thermometer |
| Ambient Operating Conditions | 5–40 °C, RH ≤85% |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 600 × 450 × 450 mm |
| Net Weight | 50 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-AC1878 |
| Price Range | USD 150–15,000 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Range | Ambient to 1000 °C |
| Temperature Control Setpoint | 775 °C ±25 °C |
| Temperature Accuracy | ±3 °C |
| Heating Rate | <20 min to 900 °C |
| Total Power Consumption | 3.5 kW |
| Crucible Options | 50 mL, 100 mL, 120 mL, 150 mL porcelain crucibles |
| External Dimensions | 680 mm × 630 mm × 520 mm |
| Heating Configuration | Triple-zone (top + dual-side) resistive heating |
| Furnace Insulation | High-purity vacuum-formed ceramic fiber |
| Enclosure | Dual-layer steel housing with welded cold-rolled steel inner chamber |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AE600 |
| Extraction Efficiency | ≥95% |
| Extraction Time | 2–4 min per sample (adjustable) |
| Agitation Method | Recirculating Pneumatic Agitation |
| Simultaneous Extraction Capacity | 6 samples |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Model | OIL-490 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (C–H Stretching Band at 2941 cm⁻¹, 2960 cm⁻¹, and 2853 cm⁻¹) |
| Detection Limit | 0.06 mg/L |
| Accuracy | ±1% relative error (within 30–50 mg/L range) |
| Wavenumber Range | 3400–2400 cm⁻¹ (equivalent to 2941–4167 nm) |
| Linearity Coefficient | r > 0.999 |
| Compliance | HJ 637–2018, HJ 1051–2019, HJ 1077–2019 |
| Connectivity | Bluetooth 5.0, Wi-Fi 802.11 b/g/n, GPRS module for remote data upload to cloud database |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-980A |
| Pricing | Available Upon Request |
| Brand | Spectra Invent (Chinainvent) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-FC1850 |
| Price Range | USD 1,400 – 14,000 |
| Standard Compliance | GB/T 12579, ASTM D892 |
| Temperature Control | 24 °C (with optional immersion chiller) and 93.5 °C |
| Temperature Stability | ±0.5 °C |
| Heating Power | 2500 W (93.5 °C bath), 800 W (24 °C bath) |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Gas Diffusion Disc Diameter | 25.4 mm ± 0.02 mm |
| Air Permeability Rate | 3000–6000 mL/min at 2.4 kPa (250 mmH₂O) |
| Sample Cylinder | 1000 mL calibrated glass cylinder (ASTM-compliant) |
| Air Flow Control | Adjustable rotameter, 16–160 mL/min, with reference mark at 94 mL/min |
| Dimensions | 1000 mm × 340 mm × 740 mm |
| Weight | 46 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-AN1823 |
| Price Range | USD 1,400 – 14,000 |
| Brand | Spectra Invent (Chinainvent) |
|---|---|
| Origin | Beijing, China |
| Model | HX-VIS1050 |
| Power | 2000 W |
| Capillary Dispensing Accuracy | ±0.2 mL |
| Compliance | SH/T 0048 |
| Brand | Spectra Invent / Chinainvent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX100 |
| Quotation | Upon Request |
| Extraction Efficiency | ≥95% |
| Extraction Cycle Time | 3 min per sample (adjustable from 1–1000 s) |
| Agitation Method | Pneumatic Oscillation |
| Simultaneous Extraction Positions | 3 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Model | HX-FP1110 |
| Detection Method | Closed Cup (Pensky-Martens Principle) |
| Operation Mode | Manual |
| Ignition Source | Pressurized Gas Flame (Propane/Butane) |
| Compliant Standards | GB/T 261–2021, ASTM D93–22 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AE-03 |
| Extraction Efficiency | 95% |
| Extraction Cycle Time | 2–4 min per sample (adjustable range: 1–30 min) |
| Agitation Method | Pneumatic Oscillation |
| Simultaneous Extraction Capacity | 3 samples |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-DR1520S |
| Operating Pressure | Atmospheric (101.3 kPa) |
| Temperature Range | −2 °C to 400 °C |
| Temperature Accuracy | ±1 °C |
| Cold Bath Temperature Range | 0 °C to 60 °C |
| Volume Measurement Range | 1 mL to 100 mL |
| Volume Resolution | 1 mL |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-AP1890A |
| Price Range | USD 1,400 – 14,000 |
| Detection Principle | Optical Turbidity Transition Monitoring |
| Temperature Control Range | 20–170 °C ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Heating Power | 160 W |
| Sample Volume | 20 mL (10 mL oil + 10 mL aniline) |
| Stirring Speed | 0–1000 rpm (adjustable via touchscreen) |
| Detection Sensor | Imported Infrared Photoelectric Sensor with Fiber-Optic Coupling |
| Display | 7-inch Color TFT Touchscreen (Chinese UI) |
| Compliance | GB/T 262, ASTM D611, ISO 6977 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-LR1838 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (W×D×H) | 520 mm × 330 mm × 570 mm |
| Net Weight | 9.5 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-FT1910 |
| Price Range | USD 150–15,000 |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | HX-MI1880 |
| Price Range | USD 140–14,000 |
| Bath Temperature Control Range | Room Temp–90 °C |
| Bath Temperature Display | LED Digital |
| Bath Temperature Accuracy | ±1 °C |
| Funnel Temperature Control Range | Room Temp–90 °C |
| Funnel Temperature Display | LED Digital |
| Funnel Temperature Accuracy | ±2 °C |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity | ≤85% |
| Total Power Consumption | ≤1200 W |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Heating Element Power | 1000 W |
| Dimensions (W×D×H) | 370 × 380 × 600 mm |
| Net Weight | 12.8 kg |
| Brand | Spectra Invent |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HX-TCR1870 |
| Measurement Range | 0.10–30.0 % (m/m) |
| Temperature Control | Ambient to 500 °C |
| Heating Rate | 10–15 °C/min |
| Sample Mass | 0.5 ± 0.1 g (black opaque liquids), 1.5 ± 0.5 g or 3.0 ± 0.5 g (transparent or translucent samples) |
| Display | 5.6-inch color touchscreen |
| Data Storage | 1000 test records with date-based retrieval |
| Weight | 15 kg |
| Brand | Spectra Invent (Chinainvent) |
|---|---|
| Origin | Beijing, China |
| Model | OIL-460 |
| Instrument Type | Laboratory Benchtop Analyzer |
| Principle | Infrared Absorption Spectrophotometry (Fourier-transform or dispersive, per HJ 637–2018) |
| Detection Limit | DL ≤ 0.06 mg/L (based on 11 measurements of C₂Cl₄ blank, 3σ criterion) |
| Accuracy | ±2% RSD for 30–50 mg/L standard solutions |
| Compliance | HJ 637–2018, HJ 1051–2019, HJ 1077–2019, GB 5084–2021, GB/T 5750.7–2023, GB 5085.6–2007 |