BrandSpectra Invent
OriginBeijing, China
ModelOIL-490
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (C–H Stretching Band at 2941 cm⁻¹, 2960 cm⁻¹, and 2853 cm⁻¹)
Detection Limit0.06 mg/L
Accuracy±1% relative error (within 30–50 mg/L range)
Wavenumber Range3400–2400 cm⁻¹ (equivalent to 2941–4167 nm)
Linearity Coefficientr > 0.999
ComplianceHJ 637–2018, HJ 1051–2019, HJ 1077–2019
ConnectivityBluetooth 5.0, Wi-Fi 802.11 b/g/n, GPRS module for remote data upload to cloud database
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent (Chinainvent)
OriginBeijing, China
ModelOIL-460
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Absorption Spectrophotometry (Fourier-transform or dispersive, per HJ 637–2018)
Detection LimitDL ≤ 0.06 mg/L (based on 11 measurements of C₂Cl₄ blank, 3σ criterion)
Accuracy±2% RSD for 30–50 mg/L standard solutions
ComplianceHJ 637–2018, HJ 1051–2019, HJ 1077–2019, GB 5084–2021, GB/T 5750.7–2023, GB 5085.6–2007
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China-manufactured)
ModelOIL-450
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (C–H Stretching Band at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Detection LimitDL ≤ 0.06 mg/L (based on 11 replicate measurements of tetrachloroethylene blank
Accuracy±2% RSD for concentrations between 30–50 mg/L
Regulatory ComplianceHJ 637–2018, HJ 1051–2019, HJ 1077–2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent (Chinainvent)
OriginBeijing, China
ModelOIL-610
PrincipleInfrared Spectrophotometry
Measurement Range0–64,000 mg/L (auto-dilution beyond range)
Detection Limit0.06 mg/L
Accuracy≤1.5% (at 30–50 mg/L)
Wavenumber Range3400–2400 cm⁻¹ (2941–4167 nm)
Absorbance Range0.0000–2.0000 AU
Wavelength Accuracy±2 nm
Wavelength Repeatability±1 cm⁻¹
Precision (RSD)≤0.6% (at 30–50 mg/L)
Linearity (r)>0.9995
Sample Volume0–650 mL
Analysis Time8 min per sample
IP RatingIP67
Display10.5-inch Windows touchscreen with keyboard
Dimensions523 × 415 × 375 mm
Power220 V, 50 Hz, 50 W
Operating Environment−5 to 45 °C, 20–85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
ModelOIL-580
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry
Detection Limit0.06 mg/L
Accuracy±2% (at 30–50 mg/L)
ComplianceHJ 637-2018, HJ 1051-2019, HJ 1077-2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelOIL-710
Instrument TypePortable
Measurement PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Measurement Range0.0–1000 mg/L
Detection Limit0.1 mg/L
Accuracy≤ ±5% RSD
Measurement Cycle Time10 seconds per sample
ComplianceDesigned to meet core requirements of EPA Method 1664A, ISO 9377-2, and HJ 637–2018 (China)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
ModelOIL-520A
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleUltraviolet (UV) Absorption Spectrophotometry (225 nm)
Detection Limit0.01 mg/L
Accuracy±2.0% (relative error vs. certified reference standards)
Sample Capacity10–14 positions on 360° motorized carousel
Sample IntroductionDual-mode (fully automated + manual)
Volume Detection MethodNon-contact ultrasonic volumetric sensing
Sample Processing ArchitectureParallelized liquid handling (aspiration, extraction, volume measurement)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSPECTRA INVENT (Chinainvent)
OriginBeijing, China
ModelOIL-630
PrincipleFluorescence Spectrophotometry
Measurement Range0–5 mg/L (auto-dilution beyond range)
Detection Limit0.005 mg/L (instrumental), 0.001 mg/L (method)
Accuracy≤2.0% error
Resolution0.001 mg/L
Excitation Wavelength310 nm ±1 nm
Emission Wavelength360 nm
Optical Path1 cm quartz fluorescence cuvette
Linearityr > 0.999
RepeatabilityRSD ≤2.0%
Sample Volume0–600 mL
Analysis Time8 min per sample
IP RatingIP67
Dimensions650 × 500 × 330 mm
Power220 V, 50 Hz, 50 W
Operating Temp/Humidity–5 to 45 °C / 20–85 % RH
Battery LifeUp to 8 h continuous operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginZhejiang, China
ModelOIL-620M
Instrument TypePortable
Measurement PrincipleUltraviolet Spectrophotometry (UV-Vis)
Measurement Range0–60 mg/L
Detection Limit≤0.005 mg/L
Accuracy±2% of reading
Resolution≤0.001 mg/L
ComplianceHJ 970–2018, GB 5084–2021
Dimensions428 × 350 × 230 mm
Weight<15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeLaboratory-Based
ModelOIL-530P
Measurement PrincipleFluorescence Spectrophotometry
Measurement Range0–5 mg/L (with automatic dilution for over-range samples)
Detection Limit0.005 mg/L
Accuracy≤2% error
Optical Range200–900 nm
Monochromator DesignDual-grating
Scan SpeedUp to 48,000 nm/min
Bandwidth AdjustmentMulti-step selectable
Sample Capacity10–14 positions on 360° rotatable sample carousel
Extraction Efficiency≥95%
Sample VesselCertified amber glass vials compliant with Chinese national standards (HJ 637–2018, GB/T 16488–1996)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
ModelOIL-510D
Instrument TypeLaboratory Benchtop Analyzer
PrincipleInfrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹)
Measurement Range0–64,000 mg/L
Detection Limit0.06 mg/L
Accuracy≤ ±1% RSD (at 30–50 mg/L)
Resolution0.0005 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSPECTRA INVENT (Chinainvent)
OriginBeijing, China
Instrument TypeLaboratory
PrincipleUltraviolet Spectrophotometry
Measurement Range0–50 mg/L (auto-dilution beyond range)
Detection LimitDL ≤ 0.005 mg/L (3×SD of 11 measurements in n-hexane blank)
Accuracy±2.0%
ComplianceHJ 970–2018, GB 5084–2021
Sample Vessel CompatibilityAdjustable for multiple standard sampling cup sizes (no sample transfer required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent (Chinainvent)
OriginBeijing, China
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Absorption Spectrophotometry (C–H Stretching Band at 2960 cm⁻¹, 2930 cm⁻¹, and 2870 cm⁻¹)
Detection Limit0.06 mg/L
Accuracy±1% RSD (at 30–50 mg/L oil concentration)
ComplianceHJ 637–2018, HJ 1051–2019, HJ 1077–2019, GB 5084–2021, GB/T 5750.7–2023, GB 5085.6–2007
Sample MatrixAqueous, soil extract, flue gas condensate, and edible oil-contaminated wastewater
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent (Chinainvent)
OriginBeijing, China
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleInfrared Spectrophotometry (Triple-Wavelength Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹)
Detection Limit0.06 mg/L
Accuracy≤1% RSD (at 30–50 mg/L)
ComplianceHJ 637–2018, HJ 1051–2019, HJ 1077–2019, GB 5084–2021, GB/T 5750.7–2023, GB 5085.6–2007
Sample PreparationLiquid–liquid extraction with tetrachloroethylene (C₂Cl₄), optional CCl₄ mode
Cell Pathlength4 cm quartz cuvette
Reagent Purity Check FunctionAutomated spectral validation of C₂Cl₄ at key wavenumbers
Baseline StabilityReal-time zero-point auto-adjustment
Calibration OptionsMulti-point standard curve, coefficient-based calculation, single-point verification
Light SourceThermally stabilized, electronically modulated IR source (≥5000 h lifetime)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
ModelOIL-680
Instrument TypePortable
Measurement PrincipleUV Spectrophotometry
Detection Limit (Method)0.01 mg/L
Accuracy±2.0%
Wavelength Range190–1000 nm
Test Wavelength225 nm
Wavelength Accuracy±1.5 nm
Wavelength Repeatability≤0.5 nm
Resolution0.0002 mg/L
Instrument Detection Limit (IDL)≤0.005 mg/L (3×SD of n=11 n-hexane blank)
Precision (RSD)≤0.6%
Linearity (r)>0.9995
Extraction Capacity4 simultaneous samples
Ingress ProtectionIP67
Dimensions (L×W×H)490 × 370 × 210 mm
Power Supply220 V, 50 Hz, 50 W
Operating Temperature−5 to +45 °C
Operating Humidity20–85 % RH
Battery Runtime>8 h continuous operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectra Invent
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelOIL-530
Instrument TypeLaboratory-Based
Measurement PrincipleFluorescence Photometry
Measurement Range0–5 mg/L (with automatic dilution for over-range samples)
Detection Limit0.005 mg/L
Accuracy≤2% error
Resolution0.001 mg/L