Add to compare
BrandLeshi
OriginBeijing, China
Model9100FIR
Instrument TypePortable FTIR Spectrometer
Resolution Options0.7 cm⁻¹ (unapodized), 1 cm⁻¹, 2 cm⁻¹, 4 cm⁻¹, 8 cm⁻¹
Scan SpeedAdjustable up to 1 scan/sec (dependent on resolution)
Signal-to-Noise Ratio (SNR)>20,000:1 (peak-to-peak, 60-sec acquisition), >120,000:1 (RMS, 60-sec acquisition)
Wavenumber Accuracy±0.01 cm⁻¹
Operating Sample TemperatureUp to 180 °C (hot-wet gas analysis)
DetectorRoom-temperature DTGS
Reference LaserVCSEL-based stabilization
Internal O₂ SensorZirconia-based electrochemical sensor
Particulate FiltrationDual-stage, <2 µm
Nitrogen Purge InterfacesDual-path (sample cell reverse purge + optical path purge)
Data OutputReal-time spectral & concentration data, Excel-compatible export
ComplianceHJ 919–2017, HJ 920–2017, HJ 1011–2018, HJ 1240–2021, HJ 1330–2023
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeshi
OriginBeijing, China
Model9100FIR
Instrument TypePortable
Spectral Range485–8500 cm⁻¹
Resolution Options1, 2, 4, or 8 cm⁻¹
Scan SpeedUp to 1 scan/sec (resolution-dependent)
Signal-to-Noise Ratio>20,000:1 (peak-to-peak, 60-sec acquisition), >120,000:1 (RMS, 60-sec acquisition)
Wavenumber Accuracy±0.01 cm⁻¹
Operating Sample TemperatureUp to 180 °C (hot-wet sampling)
DetectorAmbient-temperature DTGS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandProtea
OriginUnited Kingdom
ModelProMass
Form FactorSemi-portable (carrying case or 6U 19″ rack-mount)
Detection PrincipleQuadrupole Mass Spectrometry (QMS)
Mass RangeAdjustable (typical range 1–100 u or 1–300 u, configurable per application)
Detection LimitSub-ppb to low-ppb level (dependent on gas species and integration time)
Response Time< 100 ms for single-ion monitoring
Ion SourceElectron Impact (EI), 70 eV standard
DetectorDual-mode — Faraday Cup + Secondary Electron Multiplier (SEM)
Vacuum SystemIntegrated turbomolecular pump with backing pump
ComplianceCE-marked, RoHS-compliant, designed for industrial environments per IEC 61000-6-2/6-4
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLESHI
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeSingle Quadrupole Mass Spectrometer
GC ArchitectureLow Thermal Mass (LTM) Gas Chromatograph
Ion SourceHigh-Temperature Inert Ceramic Electron Ionization (EI) Source
Mass AnalyzerPrecision All-Metal Quadrupole
Mass Range10–500 amu (standard configuration)
DetectorElectron Multiplier with High-Energy Conversion Dynode
InjectionSplit/Splitless Injector
Column InterfaceOn-Column Heated Capillary Column
Carrier Gas FlowDirect-to-Source Pneumatic Control
PreconcentrationIntegrated Quantitative Loop and Sorbent-Based Trap (software-selectable)
ComplianceDesigned to support EPA Method 8260D, ASTM D7622, and ISO 16000-6 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandProtea
OriginUnited Kingdom
ModelAtmosFIRair
Instrument TypePortable FTIR Spectrometer
Wavenumber Range485–8500 cm⁻¹
Resolution Options1, 2, 4, or 8 cm⁻¹
Scan SpeedUp to 1 spectrum per second (resolution-dependent)
Signal-to-Noise Ratio>20,000:1 (peak-to-peak, 1-min acquisition), >120,000:1 (RMS, 1-min acquisition)
Wavenumber Accuracy±0.01 cm⁻¹
Added to wishlistRemoved from wishlist 0
Add to compare
BrandProtea
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelProMass-D
PricingAvailable Upon Request
Mass Range Options0–100 amu, 0–200 amu, or 0–300 amu (configurable)
Detection PrincipleQuadrupole Mass Filtering (QMS)
Ion DetectionDual-mode—Faraday Cup + Secondary Electron Multiplier (SEM)
Sample InletDirect Capillary Inlet
Response TimeMillisecond-scale
Application DomainReal-time Gas Phase Analysis in Lab and Process Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPerkinElmer
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTorion T-9
Instrument TypePortable GC-MS
Application FieldEnvironmental Monitoring
Weight14.5 kg
GC TechnologyLow Thermal Mass (LTM) Capillary Column
MS TechnologyMiniature Toroidal Ion Trap
Mass Range45–500 amu
ResolutionUnit resolution or better
Operating Temperature175 °C (ion trap)
Power SourceRechargeable Li-ion battery (2.5 h runtime)
Carrier GasIntegrated high-pressure helium cylinder
Sample ThroughputUp to 12 samples/hour
Temperature Ramp RateUp to 2.5 °C/s
Column Heating/CoolingRapid thermal cycling enabled by resistive LTM heating
Vacuum Requirement~10⁻³ Torr
DisplayColor touchscreen interface
SoftwareCHROMION with NIST library integration, deconvolution, spectral averaging, and quantitative methods (internal/external standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandProtea
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelProMass-T
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOntech
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelOntech710
Price RangeUSD 42,000 – 70,000
Instrument TypeOnline Gas Chromatograph
Application FieldPetrochemical Industry
Added to wishlistRemoved from wishlist 0
Add to compare
BrandOntech
ModelOntech610
TypeOnline Gas Chromatograph
ApplicationEnvironmental Emission Monitoring
ComplianceHJ 38-2017, HJ 212-2017
Sampling MethodQuantitative Loop Injection
Valve Configuration12-Position Multiport Valve
Column TechnologyDual-Column System with Heart-Cut and Back-Flush
Pressure ControlElectronic Pressure Control (EPC)
DetectionFID (Flame Ionization Detector)
Target AnalytesTotal Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes)
Enclosure RatingIP54
Operating Temperature Range5–40 °C
Power Supply220 V AC, 50 Hz
Data OutputRS485, Ethernet, 4–20 mA Analog Outputs
Communication ProtocolHJ 212-2017 Compliant Data Transmission