| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Model | Ontech860 |
| Detection Principle | Cryogenic Preconcentration Coupled with GC/GC-MS |
| Instrument Type | Benchtop Laboratory Preconcentrator |
| Compliance | HJ 759–2023, HJ 1078–2019, US EPA TO-14/TO-15, PAMS, and 2019 VOCs Monitoring Guidelines |
| Sample Inlets | Dual independent standard/injector ports + 13 auxiliary ports (optional 16-port autosampler) |
| Cooling Method | Solid-state thermoelectric (Peltier) cooling |
| Trap Stages | Three-stage cryofocusing system (Stage I: ambient water removal |
| Stage II | co-trap purification |
| Stage III | deep-cryogenic focusing at ≤ –40 °C) |
| Sample Compatibility | Summa canisters, Tedlar® gas bags, and custom pressurized vessels |
| Software Platform | Windows 7–11 (32/64-bit), FDA 21 CFR Part 11–ready audit trail, GLP-compliant method logging and QA/QC reporting |
| System Diagnostics | Real-time valve status, pressure/flow monitoring, automatic leak detection (positive/negative pressure modes), graphical pneumatic schematic |
| Sample Path | Fully heated (up to 200 °C), SilcoNert®-coated inert flow path from inlet to trap |
| Concentration Factor | Up to 10⁴–10⁵× for C₂–C₁₂ VOCs and SVOCs |
| Water Removal Efficiency | >99.9% H₂O removal while retaining water-soluble polar analytes (e.g., aldehydes, alcohols, acids) |
| Residual Carryover | < method detection limit (MDL) after hot-purge cleaning cycle |
| Flow Control | High-stability mass flow controller (MFC) with adaptive startup compensation algorithm |
| Method Flexibility | Fully programmable sequence control, user-defined time-resolved valve/temperature/flow profiles, built-in HJ 759–2023, TO-14, TO-15, and PAMS templates |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Ontech930 |
| Pricing | Available Upon Request |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Model | 9100FIR |
| Instrument Type | Portable FTIR Spectrometer |
| Resolution Options | 0.7 cm⁻¹ (unapodized), 1 cm⁻¹, 2 cm⁻¹, 4 cm⁻¹, 8 cm⁻¹ |
| Scan Speed | Adjustable up to 1 scan/sec (dependent on resolution) |
| Signal-to-Noise Ratio (SNR) | >20,000:1 (peak-to-peak, 60-sec acquisition), >120,000:1 (RMS, 60-sec acquisition) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Operating Sample Temperature | Up to 180 °C (hot-wet gas analysis) |
| Detector | Room-temperature DTGS |
| Reference Laser | VCSEL-based stabilization |
| Internal O₂ Sensor | Zirconia-based electrochemical sensor |
| Particulate Filtration | Dual-stage, <2 µm |
| Nitrogen Purge Interfaces | Dual-path (sample cell reverse purge + optical path purge) |
| Data Output | Real-time spectral & concentration data, Excel-compatible export |
| Compliance | HJ 919–2017, HJ 920–2017, HJ 1011–2018, HJ 1240–2021, HJ 1330–2023 |
| Brand | JCT |
|---|---|
| Origin | Austria |
| Product Type | Portable Gas Preconditioner with Flame Ionization Detection (FID) for NMHC Analysis |
| Instrument Category | Environmental Monitoring Instrument / Gas Analyzer |
| Configuration | Dual-Channel Sample Conditioning System |
| Flow Range | 10–100 Nl/h (Single Channel), 15–150 Nl/h (Dual Channel, per channel) |
| Maximum Combined Flow Capacity | 200 Nl/h at Rated Backpressure |
| Operating Ambient Temperature | 5–45 °C (up to 50 °C continuous) |
| Dew Point Control | +3 °C ± 0.2 °C |
| Refrigerant | R134a (non-CFC, environmentally compliant) |
| Material of Construction | PVDF (Polyvinylidene Fluoride) gas pathways |
| Integrated Components | Dual diaphragm sampling pumps, condensate removal pump, digital temperature display with alarm, precision thermal mass flow sensors, high-efficiency counterflow heat exchanger |
| Compliance | Designed for ASTM D6348, ISO 12913-1, EPA Method 25A, and EU EN 13649-1 pre-conditioning requirements |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | 9100FIR-OP4 |
| Price Range | USD 320,000 – 440,000 |
| Brand | LESHI |
|---|---|
| Model | SE300-Tech |
| Type | Portable Flue Gas Analyzer |
| Detection Principle | NDIR (CO, CO₂, HC, SO₂), Electrochemical (O₂, NO, NO₂, NH₃, H₂S), Optional NDUV (NO, NO₂, SO₂) |
| Gas Channels | Up to 6 simultaneously measurable gases (standard configuration) |
| Compliance | Designed for field-deployable combustion efficiency and emissions verification per ISO 12039, EN 15267, and EPA Method 6C/7E prerequisites |
| Power | Rechargeable Li-ion battery (≥4 hr continuous operation) |
| Display | 5.7" TFT LCD with touch interface |
| Data Storage | Removable MMC card (up to 32 GB) |
| Connectivity | USB 2.0, Bluetooth 4.2, optional RS-232 |
| Operating Temperature | 0–40 °C |
| Protection Rating | IP42 |
| Weight | ≤2.8 kg |
| Brand | Leshi |
|---|---|
| Model | SE350 |
| Type | Portable Gas Analyzer |
| Detection Principles | NDIR (CO, CO₂), Electrochemical (O₂), TCD (H₂, optional) |
| Gas Channels | Up to 4 simultaneous gases (configurable: CO, CO₂, O₂, CH₄, H₂) |
| Power Supply | Rechargeable Li-ion battery + AC adapter |
| Sampling System | Integrated diaphragm pump, flow meter, particulate filter, and sample line |
| Enclosure | IP65-rated ruggedized stainless-steel housing (chemically resistant grade) |
| Display | Backlit LCD with real-time concentration readouts |
| Output Options | 4–20 mA analog output, RS232/USB data interface, optional data logger |
| Compliance | Designed for industrial field use per IEC 61000-6-2/6-4 (EMC), ATEX Zone 2 / IECEx nA IIC T4 Ga (optional certification variant) |
| Operating Temperature | −10 °C to +50 °C |
| Storage Temperature | −20 °C to +60 °C |
| Relative Humidity | 0–95 % RH (non-condensing) |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 9100FIR-air |
| Price | USD 165,000 (FOB Beijing) |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Application Domain | Environmental Monitoring & Industrial Emissions Compliance |
| Accuracy | ±2% of reading |
| Repeatability | ±2% of full scale |
| Brand | LESHI |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 943-TGX |
| Instrument Type | Online Gas Analyzer |
| Measured Gases | H₂S, SO₂ |
| Response Time | T₉₀ < 10 s (system), < 1 s (analyzer) |
| Accuracy | ±1% FS for H₂S, ±1% FS for SO₂ |
| Measurement Range | H₂S (0–4) vol%, SO₂ (0–2) vol% |
| Detection Principle | UV Absorption Spectroscopy |
| Dimensions | 57″ W × 41.25″ H × 16″ D |
| Enclosure | Two 24″ W × 30″ H × 12″ D cabinets |
| Weight | ~275 lb (with all options) |
| Power | 110/240 VAC, 50/60 Hz, 1100 W |
| Ambient Temperature | 0–50 °C |
| Sample Flow Rate | < 5 ft³/h |
| UV Source | High-stability deuterium lamp |
| Detector | 2048-pixel CCD array |
| Display | 5.7″ LCD (640 × 480), intrinsically safe keypad |
| Output | Four isolated 4–20 mA channels (1 Hz update), relay outputs |
| Data Storage | 1 GB standard (up to 8 GB optional) |
| Zero Drift | < ±0.25% FS/day (auto-zero every 4 h) |
| Linearity & Repeatability | ±1% FS |
| Explosion Protection | Class I, Div 2, Groups C & D, T3 |
| Instrument Air | 22 SCFM @ 80 psi (20 SCFM with cooler) |
| Steam Supply | Probe –50 psi |
| Total Sulfur Range | (H₂S + SO₂) (0–6) vol% |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 9100FIRair-G |
| Technology Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Detection Principle | Mid-Infrared Absorption Spectroscopy |
| Accuracy | ≤ ±2% FS |
| Repeatability | ≤ 2% RSD |
| Measured Gases | N₂O, CH₄, CO₂, SF₆, NF₃, CFCs (Chlorofluorocarbons), PFCs (Perfluorocarbons) |
| Simultaneous Quantification Capacity | Up to 50 compounds |
| Spectral Range | 485–8500 cm⁻¹ |
| Spectral Resolution | 1 cm⁻¹ (standard), optional higher/lower resolutions available |
| Sample Cell Volume | 300 mL |
| Detector | DTGS (Deuterated Triglycine Sulfate), room-temperature operation, >10-year lifetime |
| Reference Source | Solid-State VSECL Laser, >10-year lifetime |
| Quantitative Spectral Library | ≥400 compounds (freely accessible and user-expandable) |
| Qualitative Spectral Library | 5874 compounds |
| Software Features | Auto-ranging mode, user-defined calibration file creation, spectral library import/export, GLP-compliant data logging |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Instrument Type | Portable |
| Detection Principle | Heated Flame Ionization Detection (HFID) with High-Temperature Catalytic Methane Scrubber |
| Compliance | HJ/T 38–2017, HJ 1012–2018, DB11/T 1367–2016, GB 18352.6–2016, GB 17691–2018, EN 12619, EN 13526, US EPA Compliant |
| Certification | CPA Certified, MCERTS Certified |
| Fuel Options | H₂/He mixture or pure H₂ |
| Zero Air Source | Integrated catalytic air purifier (no external zero air required) |
| Data Logging | Built-in recorder with IoT-enabled telemetry |
| Optional Modules | O₂, temperature, pressure, flow, humidity, PID/benzene speciation |
| Sample Line | Integrated heated sampling line (up to 180 °C) |
| Detection Limit | Sub-ppb range for THC (typical) |
| Response Time | T₉₀ < 3 s |
| Range Switching | Multi-range, auto-switching without power cycle |
| Filter | Removable PTFE particulate filter |
| Brand | Foedisch |
|---|---|
| Origin | Germany |
| Model | UVA17m |
| Type | Portable Multicomponent Gas Analyzer |
| Measurement Principle | High-Temperature Ultraviolet Absorption Spectroscopy |
| Response Time | ≤2 s |
| Measurable Gases | O₂, NOₓ (NO/NO₂), SO₂, NH₃, H₂S |
| Operating Temperature Range | 185–200 °C (full-path heated) |
| Detection Limits | SO₂ down to 0–50 mg/m³ |
| Sample Handling | Hot-wet, in-situ sampling without drying, dilution or cooling |
| Compliance | Designed for EN 15267-3, EN 14181, ISO 12039, and EPA Method 201A-compliant monitoring |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | 3010Plus |
| Instrument Type | Portable |
| Compliance | HJ/T 38–2017, HJ 1012–2018, GB 17691–2018, GB 18352.6–2016, DB11/T 1367–2016, DB37/T 3922 |
| Brand | Foedisch |
|---|---|
| Origin | Germany |
| Model | MCA14m |
| Measurement Principle | Non-Dispersive Infrared (NDIR) with High-Temperature Optical Path |
| Operating Temperature | 185 °C (entire gas path heated) |
| Accuracy | ≤1% FS |
| Repeatability | ±2% FS |
| Response Time (T90) | <10 s |
| Zero Calibration | Automatic, using ambient air |
| Gas Components | O₂, CO₂, H₂O, SO₂, NO, NO₂, N₂O, NH₃, HCl, CO, CH₄ |
| Sampling Method | Extractive, hot-wet |
| Power Supply | 230 V AC, 50/60 Hz |
| Enclosure Rating | IP65 |
| Compliance | EN 15267-3, EN 14181, MCERTS, ISO 14001-compatible operation |
| Data Output | RS485, Ethernet, 4–20 mA analog outputs |
| Software | PC-based configuration & data logging (free OEM software with audit trail) |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SE304 |
| Instrument Type | Portable |
| Measured Gas | SO₂ |
| Detection Principle | Non-Dispersive Infrared (NDIR) at 7.3 µm |
| Compliance | HJ 692–2011 |
| Measurement Range | Customizable up to 0–5000 ppm |
| Response Time | < 30 s (T₉₀) |
| Warm-up Time | < 60 s |
| Built-in Components | Sampling Pump, Particulate Filter, Mass Flow Meter |
| Probe Material | Stainless Steel with Flexible Sampling Hose |
| Optional | Condensate Removal Module (User-configurable) |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOLAR |
| Detection Principle | Heated Flame Ionization Detector (HFID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Dual-Channel VOC & NMHC Analyzer |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–1,000 ppm, 0–10,000 ppm |
| Resolution | ±1% of reading |
| Accuracy | ±1% of reading |
| Brand | Protea |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AtmosFIR |
| Detection Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Instrument Type | Portable |
| Typical Configuration | Multi-Component VOC Analyzer |
| Measurement Range | 0–50–100 mg/m³ (gas-dependent) |
| Spectral Resolution | 1 cm⁻¹, 2 cm⁻¹, 4 cm⁻¹, 8 cm⁻¹ |
| Accuracy | ±5% of reading |
| Response Time | 120 s |
| Certification | UK MCERTS, M22 for Stack Emission Monitoring |
| Detector | DTGS (Deuterated Triglycine Sulfate), ambient-temperature operation |
| Enclosure | IP65-rated ruggedized transport case |
| Mounting Options | Portable field unit or 19-inch rack-mountable configuration |
| Brand | LESHI |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 9100FIRair Emergency Edition |
| Price Range | USD 125,000 – 182,000 |
| Analyte Types | Gaseous, Aqueous, Solid (soil headspace/vapor) |
| Target Analytes | VOCs, inorganic gases (e.g., CO, CO₂, NO, NO₂, SO₂, NH₃, HCl, HF, CH₄), greenhouse gases |
| Response Time | ≤120 s (gas-dependent) |
| Spectral Resolution Options | 1 cm⁻¹ or 4 cm⁻¹ |
| Detector | Room-temperature DTGS |
| Light Source | VCSEL-based reference laser (10-year lifetime) |
| Built-in Sample Conditioning | Particulate filtration, N₂ purge ports (optical path & gas cell), optional integrated zirconia O₂ sensor |
| Optional Module | External H₂S electrochemical module |
| Compliance | HJ 919–2017, HJ 920–2017, HJ 1011–2018 |
| Brand | Ontech |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Ontech800 |
| Price Range | USD 770 – 1,680 |
| Brand | Foedisch |
|---|---|
| Origin | Germany |
| Model | MCA10m |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy (Full Scale) | ±0.1% |
| Repeatability | ≤2% |
| Response Time (T90) | 3 s |
| Long-Term Stability | ±2% per 8 h |
| Measured Gases | O₂, CO, CO₂, NO, SO₂, NO₂ |
| Detection Principle | Electrochemical (O₂, CO, NO, SO₂, NO₂) and NDIR (CO₂) |
| Operating Temperature Range | -10 °C to +50 °C |
| IP Rating | IP42 |
| Power Supply | Rechargeable Li-ion battery (≥6 h continuous operation) |
| Data Storage | Internal SD card (≥16 GB), up to 1 million data points |
| Compliance | EN 50379-1/-2, DIN EN 15267-3, MCERTS certified (UK), ISO 12039, ISO 10849, ASTM D6522 |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 9100-ODS |
| Price Range | USD 365,000 – 408,000 |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Application Domain | Environmental Compliance & Industrial Emissions Monitoring |
| Detection Principle | FTIR Absorption Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale |
| Target Gases | 30 Primary ODS Compounds (e.g., CFC-11, CFC-12, HCFC-22, HCFC-141b, Halon-1211, Halon-1301, CCl₄, CH₃Br, C₂H₃Cl₃) |
| Response Time | ≤ 120 s |
| Repeatability | < 2% of Full Scale |
| Brand | Leshi |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AtmosFIR |
| Instrument Principle | Infrared Absorption Spectroscopy |
| Form Factor | Portable |
| Response Time | T90 |
| Repeatability | ±2% of full scale for CO, CO₂, NO, NO₂, HCN, HCl, HBr, HF, SO₂, Acrolein |
| Spectral Range | 400–5000 cm⁻¹ |
| Detector | Ambient-Temperature DTGS |
| Quantifiable Gases | Up to 50 components simultaneously |
| Spectral Library | >5000 reference spectra (400+ freely accessible) |
| Algorithms | PLS, CLS, ILS |
| Gas Expansion Capability | User-definable spectral library extension |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | 9100 ODS |
| Price Range | USD 365,000 – 408,000 |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Application Domain | Environmental Compliance & Industrial Emissions Monitoring |
| Detection Principle | FTIR Absorption Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale |
| Target Gases | 30 Primary ODS Compounds (e.g., CFC-11, CFC-12, HCFC-22, HCFC-141b, Halon-1211, Halon-1301, CCl₄, CH₃Br, etc.) |
| Response Time | ≤ 120 s |
| Repeatability | < 2% of Full Scale |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Model | 9100FIR |
| Instrument Type | Portable |
| Spectral Range | 485–8500 cm⁻¹ |
| Resolution Options | 1, 2, 4, or 8 cm⁻¹ |
| Scan Speed | Up to 1 scan/sec (resolution-dependent) |
| Signal-to-Noise Ratio | >20,000:1 (peak-to-peak, 60-sec acquisition), >120,000:1 (RMS, 60-sec acquisition) |
| Wavenumber Accuracy | ±0.01 cm⁻¹ |
| Operating Sample Temperature | Up to 180 °C (hot-wet sampling) |
| Detector | Ambient-temperature DTGS |