Empowering Scientific Discovery

Beijing Ligtai Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelRespirometric Sensor System 6
Pressure Range500–2000 hPa
Sensor Count6
Test Vessel Capacity1000 mL
Data Acquisition Interval10 min – 48 h
Test Duration1–180 days
Stirrer Speed Control6-digit digital setting with lock function
Sensor Power2 W
Battery TypeCR2430
Sensor Dimensions50 × 70 × 70 mm
Sensor Weight80 g
Stirrer Unit Dimensions230 × 51.5 × 370 mm
Stirrer Unit Weight1.75 kg
Ingress ProtectionIP54 (EN 60529)
Safety ComplianceIEC/EN 61010-1
Databox™ Capacityup to 48 sensors (8 systems × 6 sensors)
ConnectivityUSB (RESPIROSoft™) or optional Wi-Fi (Ermes™ Cloud Platform)
SoftwareRESPIROSoft™ v5.x with audit trail, method templates, report generation, and battery-level monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETER
OriginUSA
ModelSO-431
Measurement PrincipleGalvanic (Electrochemical)
Output SignalAnalog mV (O₂ concentration proportional)
Range0–30% O₂
Repeatability< 0.1% (at 20.95% O₂)
Nonlinearity< 1%
Long-term Drift5% per year (0.6 mV/year)
O₂ Consumption0.1 μmol/day (at 20.95% O₂, 23°C)
Response Time (t₉₀)15 s
Operating Temperature–20 to +60 °C
Relative Humidity0–100% RH (non-condensing)
Pressure Range60–114 kPa
Excitation Voltage (Thermistor)2.5 V DC
Heater Supply12 V DC
Heater Power74 mW
Thermistor Current≤0.1 mA @ 70 °C
Quiescent Current0.6 mA
Active Measurement Current1.3 mA
Sensitivity10–15 mV at 20.95% O₂ (sea level, 101.3 kPa)
Zero Output< 0.5 mV
Housing MaterialPolypropylene
Diffusion CavityIntegrated micro-chamber for gas equilibration
Cable Length5 m (extendable)
DimensionsØ32 mm × 68 mm
Weight175 g (incl. cable)
Compatible Data LoggersMETER EM60 Series, ZL6 Series, ZSC
Software IntegrationZENTRA Cloud platform with auto-recognition and remote data access
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
Model6 Maxi-BMP
Sensor TypeElectronic Pressure Transducer (Mercury-Free)
Pressure Range500–2000 hPa
Display4-digit LED
InterfaceDual-button Control
Output UnitsNmL CH₄/g SV and mbar
Test Vessel Capacity1000 mL
Max. Sensors per Databox™48
Data Acquisition Interval2 h to 48 h
Test Duration10–60 days
Enclosure RatingIP54 (per EN 60529)
Safety ComplianceIEC/EN 61010-1
ConnectivityUSB (RESPIROSoft™) or Optional Wi-Fi (Ermes™ Cloud Platform)
PowerRechargeable Battery (Long Standby)
Optional ModuleErmes™ Remote Monitoring & Alert System
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLI-COR
OriginUSA
ModelLI-550
Dimensions9.1 cm × 9.1 cm × 5.2 cm
Measurement Path Length35 mm
Weight≤50 g
Power Supply5–32 VDC @ 320 mW
Output InterfacesRS-232 (LI-550), RS-232/RS-422/UART-3V (LI-550P)
Sampling Frequencies1, 2, 5, 10, 20, 40 Hz
Ultrasonic Frequency60 kHz
Wind Speed Range0–50 m/s
Wind Speed Resolution0.01 m/s
Wind Speed Accuracy±0.2 m/s (0–10 m/s), ±2% (11–30 m/s), ±4% (31–50 m/s)
Wind Direction (u/v)0–359°, Resolution: 1°, Accuracy: ±1°
Vertical Wind Component (w) Range±15°
Temperature Range−20 to +72 °C, Resolution: 0.01 °C, Accuracy: ±2.0 °C
Relative Humidity Range0–100 %RH, Resolution: 0.1 %RH, Accuracy: ±3 %RH
Barometric Pressure Range50–115 kPa, Resolution: 0.1 kPa, Accuracy: ±1.0 kPa
3D Accelerometer Range±2 g (u/v/w), Tilt (Pitch/Roll): ±90°
Magnetometer Range±50 Gauss (u/v/w), Heading Accuracy: ±5°
Dew Point & Air DensityComputed from measured T, RH, and P
Show next