| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | Respirometric Sensor System 6 |
| Pressure Range | 500–2000 hPa |
| Sensor Count | 6 |
| Test Vessel Capacity | 1000 mL |
| Data Acquisition Interval | 10 min – 48 h |
| Test Duration | 1–180 days |
| Stirrer Speed Control | 6-digit digital setting with lock function |
| Sensor Power | 2 W |
| Battery Type | CR2430 |
| Sensor Dimensions | 50 × 70 × 70 mm |
| Sensor Weight | 80 g |
| Stirrer Unit Dimensions | 230 × 51.5 × 370 mm |
| Stirrer Unit Weight | 1.75 kg |
| Ingress Protection | IP54 (EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Databox™ Capacity | up to 48 sensors (8 systems × 6 sensors) |
| Connectivity | USB (RESPIROSoft™) or optional Wi-Fi (Ermes™ Cloud Platform) |
| Software | RESPIROSoft™ v5.x with audit trail, method templates, report generation, and battery-level monitoring |
| Brand | METER |
|---|---|
| Origin | USA (Designed & Engineered in Germany) |
| Manufacturer | METER Group GmbH & Co. KG (formerly UMS) |
| Model | TEROS 32 |
| Type | Pressure-Based Tensiometer |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), ISO/IEC 17050:2010 |
| Measurement Range | -85 to +50 kPa (soil water potential), -30 to +60 °C (temperature) |
| Resolution | 0.0012 kPa, ±0.01 °C |
| Accuracy | ±0.15 kPa, ±0.1 °C (-20–40 °C), ±1 °C (outside range) |
| Output Protocols | SDI-12, DDI serial, TensioLINK™, Modbus RTU |
| Power Supply | 4.0–28.0 VDC |
| Enclosure Rating | IP68 |
| Ceramic Cup Material | Al₂O₃ (AI203), Bubble Point: 1500 kPa |
| Rod Material | PMMA |
| Corpus Material | POM-GF (glass-fiber-reinforced polyoxymethylene) |
| Probe Length Options | 40 cm / 80 cm / 120 cm |
| Diameter | 2.5 cm |
| Cable Options | Standard 5 m, up to 75 m custom |
| Connector Types | 3.5 mm stereo jack (4-pin), M12 (4-pin), or tinned bare wire |
| Installation Angle | -80° to -10° (upward), +10° to +80° (downward) |
| Operating Temperature | -30 °C (dry), 0 °C (hydrated), max 50 °C |
| Ceramic Cup Warranty | 10 years |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | SO-431 |
| Measurement Principle | Galvanic (Electrochemical) |
| Output Signal | Analog mV (O₂ concentration proportional) |
| Range | 0–30% O₂ |
| Repeatability | < 0.1% (at 20.95% O₂) |
| Nonlinearity | < 1% |
| Long-term Drift | 5% per year (0.6 mV/year) |
| O₂ Consumption | 0.1 μmol/day (at 20.95% O₂, 23°C) |
| Response Time (t₉₀) | 15 s |
| Operating Temperature | –20 to +60 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Pressure Range | 60–114 kPa |
| Excitation Voltage (Thermistor) | 2.5 V DC |
| Heater Supply | 12 V DC |
| Heater Power | 74 mW |
| Thermistor Current | ≤0.1 mA @ 70 °C |
| Quiescent Current | 0.6 mA |
| Active Measurement Current | 1.3 mA |
| Sensitivity | 10–15 mV at 20.95% O₂ (sea level, 101.3 kPa) |
| Zero Output | < 0.5 mV |
| Housing Material | Polypropylene |
| Diffusion Cavity | Integrated micro-chamber for gas equilibration |
| Cable Length | 5 m (extendable) |
| Dimensions | Ø32 mm × 68 mm |
| Weight | 175 g (incl. cable) |
| Compatible Data Loggers | METER EM60 Series, ZL6 Series, ZSC |
| Software Integration | ZENTRA Cloud platform with auto-recognition and remote data access |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 14 |
| Measurement Parameters | Water Vapor Pressure, Air Temperature, Relative Humidity, Atmospheric Pressure |
| Communication Protocols | SDI-12, DDI Serial Interface |
| Operating Temperature Range | -40 °C to +80 °C |
| RH Range | 0–100 % RH (Resolution: 0.1 % RH |
| Accuracy | ±0.8 % RH typical hysteresis |
| Long-term drift | ±0.25 % RH/year) |
| Temperature Accuracy | ±0.2 °C |
| Drift | <0.03 °C/year |
| Vapor Pressure Range | 0–47 kPa (Resolution: 0.01 kPa) |
| Barometric Pressure Range | 1–120 kPa (Accuracy: ±0.05 kPa @ 25 °C |
| Drift | <0.1 kPa/year) |
| Response Time (τ₆₃) | <25 s (RH), <165 s (T), <10 ms (P) |
| Physical Dimensions | Ø20 mm × 54 mm |
| Cable | Standard 5 m (up to 75 m customizable) |
| Power Supply | 4.0–15.0 VDC |
| Current Draw | 3.5 mA typical during measurement, 0.03 mA in standby |
| Compliance | ISO 9001:2015, EN 61326-1:2013, EN 50581:2012, 2004/108/EC, 2011/65/EU |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | ZL6 |
| Pricing | Contact for Quote |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECRN-50 |
| Pricing | Available Upon Request |
| Sensor Type | Single-Tip Tipping Bucket |
| Resolution | 1 mm |
| Output Units | gal/h or L/h (configurable) |
| Housing Material | UV-Stabilized, Waterproof, Frost-Resistant ABS Plastic |
| Operating Temperature | 0–60 °C |
| Cable Length | 5 m |
| Interface | 3.5 mm Stereo Jack (TTL Pulse Output) |
| Dimensions | 5 cm × 10 cm (Diameter × Height) |
| Data Logger Compatibility | METER ZL6, EM50/EM60 Series, ProCheck (sold separately) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T5 |
| Product Category | Pressure-Based Tensiometer |
| Measurement Principle | Ceramic Cup Equilibrium with Integrated Piezoresistive Pressure Transducer |
| Operating Range | +100 to −85 kPa (≈ pF 2.9) |
| Accuracy | ±0.5 kPa |
| Resolution | 0.1 kPa |
| Typical Drift | <0.5% per annum |
| Temperature Compensation | Yes, 0.5% FS over 25 K |
| Excitation Voltage | 10.6 VDC (5–15 VDC stable) |
| Output Signal | Ratiometric mV/V (−100 ±3 mV at +100 kPa |
| Sensor Body Diameter | 5 mm |
| Sensor Head Diameter | 20 mm |
| Sensing Area | 0.5 cm² |
| Total Length | 4 cm + custom shaft length (standard 70 mm) |
| Cable Length | Standard 5 m (customizable) |
| Power Consumption | ~1.3 mA @ 10.6 VDC |
| Bridge Configuration | Asymmetric Wheatstone Bridge |
| Sensing Element | Silicon Piezoresistive Pressure Sensor |
| Max Overpressure Tolerance | ±300 kPa |
| Material | Acrylic Shaft, Porous Ceramic Cup |
| Compatibility | Campbell Scientific dataloggers, InField 7 systems |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ECRN-50 / ECRN-100 |
| Sensor Type | Tipping Bucket (Single for ECRN-50 |
| Resolution | 1.0 mm per tip (ECRN-50) / 0.2 mm per tip (ECRN-100) |
| Output | Pulse (Open Collector) |
| Housing Material | UV-stabilized, waterproof, frost-resistant ABS plastic |
| Operating Temperature | 0–60 °C |
| Cable Length | 5 m |
| Connector Type | 3.5 mm mono audio jack |
| Compatible Data Loggers | METER ZL6, EM50/EM60 series, ProCheck |
| Compliance | Designed for long-term field deployment in accordance with ASTM D3478 and ISO 9060:2018 Class B recommendations for precipitation measurement |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | ECRN-100 |
| Resolution | 0.2 mm |
| Sensor Type | Dual tipping bucket |
| Housing Material | UV-stabilized, waterproof, frost-resistant ABS plastic |
| Operating Temperature | 0–60 °C |
| Cable Length | 5 m |
| Interface | 3.5 mm stereo audio jack (pulse output) |
| Dimensions | 17 cm × 14.2 cm |
| Data Logger Compatibility | METER ZL6, EM50/EM60, ProCheck (sold separately) |
| Certification Compliance | Designed for long-term field deployment in accordance with WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9060:2018 Class B recommendations for precipitation measurement |
| Brand | METER |
|---|---|
| Origin | Germany |
| Model | TEROS 06 |
| Temperature Range | –20 to 50 °C |
| Accuracy | ±0.1 °C (0–30 °C), ±0.2 °C (–20 to 50 °C) |
| Resolution | ±0.03 °C |
| Measurement Depths | –5, –10, –20, –30, –50, –100 cm |
| Output Interfaces | SDI-12, RS-485 (Modbus RTU / tensioLINK), DDI |
| Power Supply | 3.9–28.0 VDC |
| Operating Temperature | –30 to 60 °C |
| Probe Diameter | 20 mm |
| Length | 1040 mm |
| Housing Material | PA66GF30 |
| Sensing Element | Stainless Steel |
| Cable Standard | 4.5 m (custom up to 75 m) |
| Compliance | ISO 9001:2015, CE (EMC per ISO/IEC 17050:2010) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Pressure-Based Water Level Sensor |
| Model | HYDROS 21 |
| Measurement Principle | Absolute pressure transduction with barometric compensation |
| Depth Range | 0–1000 cm H₂O |
| EC Range | 0–120 dS/m |
| Temperature Range | −40 to +60 °C |
| Resolution | 1 mm (depth), 0.001 dS/m (EC), 0.1 °C (temp) |
| Accuracy | ±0.25% FS @20 °C (depth), ±0.01 dS/m or ±10% (EC), ±1 °C (temp) |
| Output Interface | DDI serial or SDI-12 |
| Power Supply | 4.0–15.0 VDC |
| Operating Temperature | 0–60 °C |
| Dimensions | Ø3.4 cm × 9 cm |
| Cable | Standard 10.0 m (optional 20.0/40.0 m), Ø6.00 ± 0.25 mm with 0.80 mm jacket |
| Connector | 3.5 mm stereo jack or tinned 3-wire lead |
| Current Draw | 2.5–8.0 mA (active), ~0.35 mA (standby) |
| Startup Time | 52–100 ms (DDI), ≤750 ms (SDI-12), ≤200 ms (SDI-12 w/ DDI disabled) |
| Measurement Duration | ≤600 ms |
| Compliance | ISO 9001:2015 certified manufacturing |
| CE marked per EM ISO/IEC 17050 | 2010 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | 6 Maxi-BMP |
| Sensor Type | Electronic Pressure Transducer (Mercury-Free) |
| Pressure Range | 500–2000 hPa |
| Display | 4-digit LED |
| Interface | Dual-button Control |
| Output Units | NmL CH₄/g SV and mbar |
| Test Vessel Capacity | 1000 mL |
| Max. Sensors per Databox™ | 48 |
| Data Acquisition Interval | 2 h to 48 h |
| Test Duration | 10–60 days |
| Enclosure Rating | IP54 (per EN 60529) |
| Safety Compliance | IEC/EN 61010-1 |
| Connectivity | USB (RESPIROSoft™) or Optional Wi-Fi (Ermes™ Cloud Platform) |
| Power | Rechargeable Battery (Long Standby) |
| Optional Module | Ermes™ Remote Monitoring & Alert System |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP-IRT |
| Field of Application | Non-contact plant canopy surface temperature measurement for irrigation scheduling and physiological stress monitoring |
| Viewing Angle | 20° |
| Measurement Accuracy | ±0.5°C (ambient temperature range 0–50°C) |
| Operating Temperature | 0–50°C |
| Power Supply | Rechargeable battery with optional 2 W solar panel |
| Output Options | Analog (0–5 V or 4–20 mA), SDI-12, or wireless (SapIP mesh protocol) |
| Data Logging | Configurable interval from 10 s to 60 min |
| Network Topology | Self-organizing wireless mesh (SapIP) supporting up to 200 sensor nodes per network |
| Transmission Range | Up to 1.6 km radius (line-of-sight, terrain-dependent) |
| Compliance | CE, FCC Part 15, RoHS |
| Software Integration | Watcher™ desktop application (Windows), cloud-based data dashboard (HTTPS/TLS encrypted) |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-550 |
| Dimensions | 9.1 cm × 9.1 cm × 5.2 cm |
| Measurement Path Length | 35 mm |
| Weight | ≤50 g |
| Power Supply | 5–32 VDC @ 320 mW |
| Output Interfaces | RS-232 (LI-550), RS-232/RS-422/UART-3V (LI-550P) |
| Sampling Frequencies | 1, 2, 5, 10, 20, 40 Hz |
| Ultrasonic Frequency | 60 kHz |
| Wind Speed Range | 0–50 m/s |
| Wind Speed Resolution | 0.01 m/s |
| Wind Speed Accuracy | ±0.2 m/s (0–10 m/s), ±2% (11–30 m/s), ±4% (31–50 m/s) |
| Wind Direction (u/v) | 0–359°, Resolution: 1°, Accuracy: ±1° |
| Vertical Wind Component (w) Range | ±15° |
| Temperature Range | −20 to +72 °C, Resolution: 0.01 °C, Accuracy: ±2.0 °C |
| Relative Humidity Range | 0–100 %RH, Resolution: 0.1 %RH, Accuracy: ±3 %RH |
| Barometric Pressure Range | 50–115 kPa, Resolution: 0.1 kPa, Accuracy: ±1.0 kPa |
| 3D Accelerometer Range | ±2 g (u/v/w), Tilt (Pitch/Roll): ±90° |
| Magnetometer Range | ±50 Gauss (u/v/w), Heading Accuracy: ±5° |
| Dew Point & Air Density | Computed from measured T, RH, and P |