- All
- Favorite
- Popular
- Most rated
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | SapIP-MICRO |
| Instrument Type | Wireless Mesh-Based Environmental Monitoring System |
| Data Transmission | LoRaWAN / Cellular (SPIP-CELL optional) |
| Network Topology | Self-Healing Mesh |
| Max Nodes per Network | 25 |
| Inter-Node Range | 300–500 m (line-of-sight, SPIP-24K radio) |
| Operating Temperature | −40 to +70 °C |
| Relative Humidity Range | 0–100 % RH |
| Accuracy | ±3 % RH (0–90 % RH, 20 °C), ±5 % RH (90–100 % RH) |
| Air Temperature Range | −40 to +60 °C |
| Accuracy | ±0.6 °C |
| Solar Radiation Range | 0–2000 W/m² |
| Spectral Response | 360–1120 nm |
| Absolute Accuracy | ±5 % |
| Rainfall Resolution | 0.25 mm |
| Accuracy | ±4 % or ±1 tip (0.2–50.0 mm/hr) |
| Wind Speed Range | 0–50 m/s |
| Accuracy | ±0.5 m/s |
| Wind Direction Range | 0–360° |
| Accuracy | ±5° |
| Onboard Memory | 30,000 records |
| Power | 7 Ah rechargeable battery + 10 W solar panel |
| Input Channels | 8 differential analog inputs |
| ETP Calculation | FAO-56 Penman-Monteith supported in firmware |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-7500RS |
| CO₂ Range | 0–3000 µmol/mol |
| H₂O Range | 0–60 mmol/mol |
| Accuracy (CO₂/H₂O) | <1% |
| Zero Drift (CO₂) | ±0.1 µmol/mol/°C (typ.), ±0.3 µmol/mol/°C (max.) |
| Zero Drift (H₂O) | ±0.03 mmol/mol/°C (typ.), ±0.05 mmol/mol/°C (max.) |
| RMS Noise @5 Hz (CO₂) | 0.08 µmol/mol |
| RMS Noise @5 Hz (H₂O) | 0.0034 mmol/mol |
| Gain Drift (CO₂) | ±0.02% /°C (typ.) |
| Gain Drift (H₂O) | ±0.15% /°C (typ.) |
| Cross-Sensitivity (CO₂ to H₂O) | ±2.0×10⁻⁵ mol CO₂/mol H₂O (typ.) |
| Cross-Sensitivity (H₂O to CO₂) | ±0.02 mol H₂O/mol CO₂ (typ.) |
| Sampling Rate | 150 Hz |
| Bandwidth Options | 5, 10, or 20 Hz |
| Detector | Thermoelectrically Cooled PbSe |
| Optical Path Length | 12.5 cm |
| Air Temperature Sensor | 10 kΩ thermistor (–40 to 70 °C |
| Pressure Sensor | 20–110 kPa (±0.4 kPa accuracy) |
| Operating Temp | –25 to 50 °C (extendable to –40 °C) |
| IP Rating | IP65 |
| Power | 10.5–30 VDC |
| Power Consumption | 4 W (typ.), ≤8 W (full range) |
| Probe Dimensions | Ø6.5 × 30 cm |
| Probe Weight | 0.67 kg (1.3 kg with base) |
| DSI Box Dimensions | 13.24 × 14.64 × 6.24 cm (H×W×D) |
| DSI Box Weight | 0.93 kg |
| Data Interface | Ethernet |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | Biomet |
| Instrument Type | Integrated Eddy Covariance-Compatible Biometeorological Sensor System |
| Compliance | Designed for ASTM D7289, ISO 16485, and FLUXNET-compatible data acquisition frameworks |
| Data Synchronization | Time-synchronized with LI-COR gas analyzers (e.g., LI-7200/7810) and ultrasonic anemometers (e.g., LI-7500A/RS) via DAqM module |
| Software Integration | Fully compatible with SmartFlux® and EddyPro® v8.2+ for flux partitioning, gap-filling, and uncertainty propagation |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ZL6 |
| Instrument Type | Compact Wireless Weather Station |
| Power | Integrated Solar Panel + Rechargeable NiMH Battery |
| Data Connectivity | GSM (2G/3G) to Zentra Cloud |
| Local Storage Capacity | 40,000–80,000+ records |
| Sensor Interfaces | 6 universal analog/digital ports |
| IP Rating | IP67 enclosure |
| Operating Temperature Range | –25°C to 60°C |
| Compliance | FCC Part 15, CE, RoHS |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ZL6 Micro-Meteorological Monitoring System |
| Instrument Type | Portable Weather Station |
| Power | Integrated Solar Panel + NiMH Rechargeable Battery (3+ years life) or AA Alkaline Batteries (3–12 months) |
| Sensor Interfaces | 6 universal analog/digital ports |
| Expandable Sensors | 29 compatible sensor models |
| Data Storage Capacity | 40,000–80,000+ records (configurable) |
| Connectivity | Embedded GSM module (2G/3G fallback), ZENTRA Cloud integration |
| Enclosure | IP68-rated, UV-stabilized, radiation-shielded housing |
| Deployment | Plug-and-play sensor interface, no programming required |
| Compliance | Designed for GLP-aligned environmental field studies |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | EddyPro |
| Type | Eddy Covariance Data Processing Software |
| Compliance | ASTM D618, ISO 14050 (Greenhouse Gas Monitoring Framework), AmeriFlux & GHG-Europe Data Standards |
| Software Architecture | Windows-based desktop application (Local Edition) and embedded real-time firmware (Field Edition for SmartFlux® 2) |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-7200RS |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy with Thermopile-Cooled PbSe Detectors |
| CO₂ Range | 0–3000 µmol/mol |
| H₂O Range | 0–60 mmol/mol |
| Accuracy | <1% for CO₂, <2% for H₂O |
| Zero Drift (CO₂) | ±0.1 µmol/mol/°C (typ.), ±0.3 µmol/mol/°C (max.) |
| Zero Drift (H₂O) | ±0.03 mmol/mol/°C (typ.), ±0.05 mmol/mol/°C (max.) |
| RMS Noise @5 Hz | 0.08 µmol/mol (CO₂), 0.0034 mmol/mol (H₂O) |
| Bandwidth Options | 5, 10, or 20 Hz |
| Operating Temperature | −25 to +50 °C (extended: −40 to +50 °C) |
| Power | 10.5–30 VDC |
| Data Storage | 16 GB industrial-grade USB flash drive |
| Communication | Ethernet, SDM (>50 Hz), RS-232 (115.2 kbps, ≤20 Hz), 6 DACs (0–5 V, 300 Hz) |
| Analog Inputs | 4 differential, bipolar ±5 V, 300 Hz |
| Detector | Thermoelectrically cooled PbSe photodetector |
| Probe Dimensions | Ø7.5 cm × 31 cm |
| Weight | 1.8 kg |
| Interface Unit (LI-7550) | 35 × 30 × 15 cm |
| Flow Module (7200-101) | 15 LPM, 35 × 30 × 15 cm, 6.15 kg, <16 W |
| Heated/Anti-Condensation Inlet Tube | 71.1 cm length, ID 5.33 mm, OD 6.35 mm, −40 to +50 °C, 0.1–6 W |
| Insulated Inlet Tube | up to 1 m, same ID/OD |
| Auxiliary Sensor (7550-101) | 11.5 × 6.5 × 4.2 cm, 0.39 kg |
| Compliance | Designed for GLP/GMP-aligned eddy covariance deployments |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model Series | LI-COR Radiation Sensor Series |
| Instrument Type | Pyranometer / PAR Quantum Sensor / Illuminance Sensor / Underwater PAR Sensor |
| Compliance | ISO 9070, ASTM E892, WMO Guide to Meteorological Instruments and Methods of Observation |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 41 |
| Instrument Type | All-in-One Environmental Weather Station |
| Communication Protocol | SDI-12 |
| Power Supply | 3.6–15.0 VDC |
| Operating Temperature | −50 to +60 °C |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Dimensions | Ø10.0 cm × 28 cm |
| Compliance | CE-marked per ISO/IEC 17050:2010 |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | InteliMet Advantage |
| Sensor Compatibility | GMX500/GMX600 Integrated Meteorological Sensors |
| Power Supply | 10 W Solar Panel with Battery Backup |
| Communication Options | Wired USB/RS-485 or Optional 2G/3G DTU/VPN Cellular Module |
| Environmental Rating | IP66 |
| EMC Compliance | BS EN 61326:2013, FCC CFR 47 Part 15.109 |
| Operating Temperature Range | -40 °C to +70 °C |
| Wind Speed Range | 0.1–60 m/s (±3% @ 0–40 m/s |
| Wind Direction Range | 0–359° (±3° @ 0–40 m/s |
| Atmospheric Pressure Range | 300–1100 hPa (±0.5 hPa @ 25 °C) |
| Air Temperature Range | -40–70 °C (±0.3 °C @ 20 °C) |
| Relative Humidity Range | 0–100 %RH (±2 %RH @ 10–90 %RH, 20 °C) |
| Dew Point Accuracy | ±0.3 °C @ 20 °C |
| Rainfall Measurement (InteliMet Advantage 5) | Tipping Bucket (UV-stabilized ABS |
| Rainfall Measurement (InteliMet Advantage 6) | Optical Sensor (0–150 mm/hr |
| Solar Radiation Spectral Range | 380–1120 nm (±5% absolute accuracy) |
| Data Processing | ETP calculation per Lascano & Van Bavel (ASA, 2006) |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-7500DS |
| Power Consumption | 4 W (typical), up to 8 W (operational range) |
| CO₂ Measurement Range | 0–3000 µmol/mol |
| H₂O Measurement Range | 0–60 mmol/mol |
| Accuracy | <1% for both CO₂ and H₂O |
| Zero Drift (CO₂) | ±0.1 µmol/mol/°C (typ.), ±0.3 µmol/mol/°C (max.) |
| Zero Drift (H₂O) | ±0.03 mmol/mol/°C (typ.), ±0.05 mmol/mol/°C (max.) |
| RMS Noise @5 Hz (CO₂) | 0.08 µmol/mol |
| RMS Noise @5 Hz (H₂O) | 0.0034 mmol/mol |
| Bandwidth Options | 5, 10, or 20 Hz |
| Sampling Frequency | 150 Hz |
| Detector | Thermoelectrically Cooled PbSe |
| Optical Path Length | 12.5 cm |
| Data Interface | Ethernet |
| Operating Temperature | −25 to +50 °C (extendable to −40 to +50 °C) |
| IP Rating | IP65 |
| Air Temperature Sensor | 10 kΩ thermistor (−40 to +70 °C, ±0.25 °C accuracy) |
| Pressure Sensor | 20–110 kPa (±0.4 kPa accuracy) |
| Probe Dimensions | Ø6.5 × 30 cm |
| Weight | 0.67 kg (probe only), 1.3 kg (with base) |
| DSI Box Dimensions | 13.24 × 14.64 × 6.24 cm (H×W×D) |
| Weight | 0.93 kg |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-7700-EC |
| Instrument Type | Eddy Covariance Flux Measurement System |
| Gas Species | CH₄, CO₂, H₂O |
| Measurement Principle | Open-Path Infrared Absorption Spectroscopy (CH₄), Dual-Wavelength Near-Infrared Absorption (CO₂/H₂O) |
| Data Output Rate | ≥10 Hz |
| Power Consumption | <12 W (typical system configuration) |
| Operating Temperature Range | −25 to +45 °C |
| Enclosure Rating | IP65 |
| Compliance | Designed for GLP/GMP-aligned environmental monitoring workflows |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | SMARTFlux |
| Instrument Type | Eddy Covariance Flux Processing Module |
| Compatibility | LI-7500DS, LI-7200RS gas analyzers |
| Clock Synchronization | GPS + IEEE 1588 Precision Time Protocol (PTP) |
| Data Processing | Onboard EddyPro® software v8.2+ |
| Power Output | 24 VDC for 3D sonic anemometers |
| Interface | Digital SDI-12 & RS-485 support for sonic anemometers |
| Enclosure Rating | IP65-rated housing optional |
| Remote Monitoring | Integrated FluxSuite® web interface with email alerting |
| Brand | Dynamax |
|---|---|
| Origin | USA |
| Model | Dynamet |
| Sensor Core | Gill MaxiMet™ 500 (Dynamet 2 & 5) / MaxiMet™ 600 (Dynamet 6) |
| Wind Measurement | Ultrasonic |
| Data Capacity | 100,000 records |
| ETP Calculation | Penman–Van Bavel (PENV) algorithm |
| Communication | Optional 2G/3G DTU or VPN-based cellular transmission |
| Compliance | ASTM D5098, ISO 17025-aligned sensor validation protocols, WMO Guide to Instruments and Methods of Observation (CIMO) reference-class deployment |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ATMOS 41W |
| Instrument Type | Portable All-in-One Weather Station |
| Certifications | ISO 9001:2015, CE (EMC per ISO/IEC 17050:2010) |
| Power | 6× AA Alkaline or NiMH batteries (solar-rechargeable option available) |
| Communication | LTE-M/NB-IoT & 3G cellular (global carrier support), Bluetooth 5.2 BLE, integrated 56-channel GPS/QZSS |
| Data Storage | 8 MB non-volatile flash memory (≥100,000 records) |
| Operating Temperature | –40 °C to +60 °C (RH & barometric sensors functional at –40 °C |
| extended air temperature range | –63 °C to +60 °C) |
| Dimensions | 16.5 cm (W) × 31.8 cm (H) |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | GHG-RS2 (with SmartFlux® and LI-7500DS/LI-7700) |
| Instrument Type | Eddy Covariance Flux System for Greenhouse Gases |
| Power Consumption | <12 W (system-wide, solar-compatible) |
| Data Output Frequency | Up to 40 Hz |
| Compliance | ASTM D6348, ISO 14064-3, US EPA GHG Reporting Program (Subpart H), FLUXNET Best Practices |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluxSuite |
| Instrument Type | Eddy Covariance Network Data Management Platform |
| Deployment | Web-Based SaaS Architecture |
| Compliance Framework | Supports GLP/GMP-aligned audit trails, ISO/IEC 17025 data integrity principles, and FDA 21 CFR Part 11–compatible user authentication (role-based access control) |
Show next