BrandVELP
OriginItaly
ModelUDK 159
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Detection Range≥ 0.1 mg N
Distillation Time0–99 min
Repeatability≤ 1 %
Sample Weight Capacity10 g
Nitrogen Recovery Rate≥ 99.5 %
Power Consumption2200 W
Dimensions (L×W×H)416 mm × 385 mm × 780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 129
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Determination Range0.1–200 mg
Distillation Time3–5 min per sample
Repeatability±0.5%
Sample Weight Capacity≤5 g
Nitrogen Recovery Rate≥99.5%
Power Consumption2100 W
Dimensions (W×D×H)385×416×780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 169 & AutoKJEL
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Detection Range≥0.1 mg N
Distillation Time1–99 min
Repeatability≤1%
Sample Weight Capacity10 g
Nitrogen Recovery Rate>99.5%
Power Consumption2200 W
Dimensions (W×D×H)385 mm × 416 mm × 780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelNDA 701/702
PrincipleDumas Combustion Method
Detection LimitNDA 701: 0.003 mg N (He)
NDA 7020.001 mg N (He) or 0.01 mg N (Ar)
Analysis Time3–4 min per sample
Repeatability (RSD)<0.5% using EDTA standard (9.57% N)
Sample Weight1 g
Recovery Rate>99.5%
Power Consumption1400 W
Dimensions (W×D×H)655 × 510 × 410 mm
Weight54 kg
Carrier GasHe (≥99.999%) or Ar (≥99.999%)
Oxygen SupplyO₂ (≥99.999%, 2 bar)
Combustion Temperature1030 °C
DetectorAuto-calibrating Thermal Conductivity Detector (TCD)
ThroughputUp to 117 samples (4 × 30-position auto-samplers)
ComplianceASTM D515, ISO 13878, AOAC 992.15, EN ISO 16634-1/-2, USP <285>, FDA 21 CFR Part 11 ready (with Ermes software license)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 139
Instrument TypeKjeldahl Nitrogen Determinator
Measurement Range0.01–100 mg N
Distillation Time4 min (for 100 mL sample)
Repeatability≤1%
Sample Mass Requirement≥0.1 g N
Recovery Rate≥99.5%
Power Consumption2100 W
Dimensions (W×D×H)385 × 416 × 780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 149
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Determination Range0.1–200 mg
Distillation Time3–4 min/sample
Repeatability±0.5%
Sample Weight Capacity≤5 g
Nitrogen Recovery Rate≥99%
Power Consumption2100 W
Dimensions (W×D×H)380 × 416 × 780 mm