BrandVELP
OriginItaly
ModelUDK 159
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Detection Range≥ 0.1 mg N
Distillation Time0–99 min
Repeatability≤ 1 %
Sample Weight Capacity10 g
Nitrogen Recovery Rate≥ 99.5 %
Power Consumption2200 W
Dimensions (L×W×H)416 mm × 385 mm × 780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 129
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Determination Range0.1–200 mg
Distillation Time3–5 min per sample
Repeatability±0.5%
Sample Weight Capacity≤5 g
Nitrogen Recovery Rate≥99.5%
Power Consumption2100 W
Dimensions (W×D×H)385×416×780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelEMA 502 CHNS-O
Measurement PrincipleHigh-Temperature Combustion (CHNS) and Pyrolysis (O) with Gas Chromatography–Thermal Conductivity Detection (GC-TCD)
Sample ThroughputUp to 117 samples per run
Analysis Time≥12 min (CHNS), ≥6 min (O)
Detection MethodTCD (no reference gas required)
Sample FormSolid, semi-solid, liquid
Max Sample Mass100 mg (C-dependent)
Calibration Range (He carrier)C 0.001–20 mg, H 0.001–5 mg, N 0.001–20 mg, S 0.01–6 mg, O 0.005–6 mg
Precision (RSD)≤0.2% (sulfanilic acid)
Operating Temperatures1030 °C (CHNS combustion), 1060 °C (O pyrolysis)
Carrier GasesHelium or Argon (Ar for CHN only)
ComplianceAOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA, FDA 21 CFR Part 11 (optional)
SoftwareEMASoft™ with LIMS export, Ermes Cloud integration
ConnectivityUSB, RS232, Wi-Fi/LAN
Power570 W
Dimensions (W×H×D)500 × 510 × 410 mm (680 mm H with autosampler)
Weight45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 169 & AutoKJEL
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Detection Range≥0.1 mg N
Distillation Time1–99 min
Repeatability≤1%
Sample Weight Capacity10 g
Nitrogen Recovery Rate>99.5%
Power Consumption2200 W
Dimensions (W×D×H)385 mm × 416 mm × 780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelNDA 701/702
PrincipleDumas Combustion Method
Detection LimitNDA 701: 0.003 mg N (He)
NDA 7020.001 mg N (He) or 0.01 mg N (Ar)
Analysis Time3–4 min per sample
Repeatability (RSD)<0.5% using EDTA standard (9.57% N)
Sample Weight1 g
Recovery Rate>99.5%
Power Consumption1400 W
Dimensions (W×D×H)655 × 510 × 410 mm
Weight54 kg
Carrier GasHe (≥99.999%) or Ar (≥99.999%)
Oxygen SupplyO₂ (≥99.999%, 2 bar)
Combustion Temperature1030 °C
DetectorAuto-calibrating Thermal Conductivity Detector (TCD)
ThroughputUp to 117 samples (4 × 30-position auto-samplers)
ComplianceASTM D515, ISO 13878, AOAC 992.15, EN ISO 16634-1/-2, USP <285>, FDA 21 CFR Part 11 ready (with Ermes software license)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 139
Instrument TypeKjeldahl Nitrogen Determinator
Measurement Range0.01–100 mg N
Distillation Time4 min (for 100 mL sample)
Repeatability≤1%
Sample Mass Requirement≥0.1 g N
Recovery Rate≥99.5%
Power Consumption2100 W
Dimensions (W×D×H)385 × 416 × 780 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelCN 802
Analysis MethodHigh-Temperature Combustion (1030 °C)
Detection PrincipleTCD for N, NDIR for C
Analysis Time3–4 min per sample
Sample WeightUp to 1 g
Detection Limits0.001 mg N (He), 0.01 mg N (Ar), 0.01 mg C
Repeatability (RSD)≤0.5% (100 mg EDTA standard)
Recovery>99.5%
Carrier GasHelium or Argon (99.999% purity, 2 bar)
Oxygen Purity99.999%, 2 bar
Power1400 W, 230 V / 50–60 Hz
Dimensions (W×H×D)655×510×410 mm (655×690×410 mm with autosampler)
Weight54 kg
ComplianceAOAC, AOCS, AACC, ISO, EN, CEN, EPA, IFFO
ConnectivityUSB, RS232, Wi-Fi/Ethernet to VELP Ermes Cloud Platform
SoftwareCN802 Control & Analysis Suite with GLP-compliant audit trail, real-time graphing, automated C/N ratio calculation, and report generation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelSMS
Dimensions300 × 500 × 190 mm
Weight3.5 kg
ConstructionEpoxy-coated stainless steel
Absorption StagesThree-stage (condensation → alkaline neutralization → activated carbon adsorption)
Pump TypeRecirculating water-based absorption pump (JP series)
Vacuum ControlAdjustable
Optional AccessoriesReplacement activated carbon packs (A00001164), activated carbon filter cartridge (A00001165), IQ/OQ validation documentation (A00000252)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVELP
OriginItaly
ModelUDK 149
Instrument TypeKjeldahl Nitrogen Determinator
Nitrogen Determination Range0.1–200 mg
Distillation Time3–4 min/sample
Repeatability±0.5%
Sample Weight Capacity≤5 g
Nitrogen Recovery Rate≥99%
Power Consumption2100 W
Dimensions (W×D×H)380 × 416 × 780 mm