Empowering Scientific Discovery

Beijing Ligtai Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP21
Spectral Range285–2800 nm
Sensitivity7–14 µV/W/m²
Response Time5 s
Zero Offset A< 7 W/m²
Zero Offset B< 2 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 10 W/m²
Temperature Dependence of Sensitivity (−20 °C to +50 °C)< 1 %
Operating Temperature Range−40 °C to +80 °C
Maximum Solar Irradiance4000 W/m²
Field of View180°
Output Signal0–20 mV (passive, no power required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP22
Spectral Range210–3600 nm
Response Time (63%)< 0.5 s
Response Time (95%)< 0.2 s
Zero Offset A< 3 W/m²
Zero Offset B< 1 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 5 W/m²
Temperature Dependence of Sensitivity (−20 °C to +50 °C)< 0.3 %
Analog Output (-V)0–1 V
Analog Output (-A)4–20 mA
Digital Output2-wire RS-485
Supply Voltage5–30 VDC
Integrated Desiccant Lifetime≥10 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP10
Spectral Range285–2800 nm
Sensitivity7–14 µV/W/m²
Response Time< 5 s
Zero Offset A< 7 W/m²
Zero Offset B< 2 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 10 W/m²
Temperature Dependence of Sensitivity (−10 °C to +40 °C)< 1 %
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance4000 W/m²
Field of View180°
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: Kipp & Zonen
OriginNetherlands
ModelCMP22
Spectral Range200–3600 nm
Sensitivity7–14 µV/W/m²
Response Time5 s
Zero Offset A< 3 W/m²
Zero Offset B< 1 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 5 W/m²
Temperature Dependence of Sensitivity (−20 °C to +50 °C)< 0.5 %
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance4000 W/m²
Field of View180°
Output Signal0–20 mV (passive, no power required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP12 Pyranometer with Albedo Measurement Kit
ClassificationISO 9060:2018 Class A (Secondary Standard)
Spectral Range285–3000 nm
Response Time (95%)< 1.5 s
Zero Offset (Thermal, 5 K/h)±1 W/m²
Non-linearity< ±0.2 % (0–2000 W/m²)
Tilt Error< ±1 % (0–90°, 1000 W/m²)
Operating Temperature−40 °C to +80 °C
Output SignalAnalog (mV) and Digital (RS-485 / Modbus RTU)
HeatingIntegrated dome heater (12–30 VDC, max 2.5 W)
ComplianceISO 9060:2018 Class A, IEC 61724-1:2021, WMO Guide to Instruments (2022)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelLAS MkII ET
Measurement PrincipleOptical Scintillometry (Large-Aperture Scintillometer)
Core OutputsLatent Heat Flux (LvE), Evapotranspiration (ET), Sensible Heat Flux (H), Path-Averaged Turbulent Fluxes
Data LoggerCOMBILOG (12 VDC, IP65 Stainless Steel Enclosure with Overvoltage Protection)
Radiation SensorNR Lite2 Net Radiometer
Meteorological SensorsDual-Height Air Temperature, Dual-Depth Soil Temperature, Anemometer & Wind Vane, Barometric Pressure Sensor
Mounting Mast4 m Telescopic Guyed Mast with Lightning Rod, Ground Plate, and Sensor Mounting Hardware
SoftwareEVATION® (Real-Time Monitoring, Post-Processing, CSV/NetCDF Export, Multi-Source Data Integration)
ComplianceDesigned for Long-Term Field Deployment per IEC 60529 (IP65), ASTM E1371 (Scintillometer Performance), ISO 20607 (Micrometeorological Flux Measurements), GLP-Ready Data Logging Architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCUV5
Spectral Range280–400 nm
Sensitivity300–500 µV/(W/m²)
Temperature Response< −0.3 °C
Response Time< 1 s
Non-linearity Error< 1 %
Max Solar Irradiance400 W/m²
Operating Temperature−40 to +80 °C
Directional Error (up to 80°, 1000 W/m² beam)< 5 W/m²
Field of View180°
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelNR Lite2
Spectral Range200–100,000 nm
Sensitivity10 µV/W/m²
Response Time< 20 s
Operating Temperature Range-30 °C to +70 °C
ComplianceCE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCM4
Spectral Range300–2800 nm
Sensitivity4–10 µV/W/m²
Response Time< 8 s
Zero-Offset A< 4 W/m²
Zero-Offset B< 15 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 20 W/m²
Temperature Dependence of Sensitivity (-20 °C to +150 °C, over any 50 °C interval)< 3 %
Operating Temperature Range-40 °C to +150 °C
Maximum Irradiance4000 W/m²
Field of View180°
Integrated Pt-100 Temperature SensorYes
Internal Class I Temperature CompensationYes
High-Temperature Signal Cable Length10 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSP Lite2
Spectral Range400–1100 nm
Sensitivity60–100 µV/W·m⁻²
Response Time (95%)< 500 ns
Directional Error (up to 80°, 1000 W/m² beam)< 10 W/m²
Temperature Response< −0.15 %/°C
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance2000 W/m²
Field of View180°
OutputAnalog voltage (mV), proportional to irradiance
Calibration CertificateTraceable to WRR (World Radiometric Reference)
CableIntegrated high-quality yellow cable (5 m standard)
MountingIntegrated leveling bubble and adjustment screws
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCA2
Spectral Range0.3–3 µm (with quartz window) / 0.2–50 µm (bare detector)
Sensitivity7–20 µV/W/m²
Impedance20–200 Ω
Output Range0–30 mV
Maximum Irradiance2000 W/m²
Response Time (63%)< 6 s
Response Time (95%)< 18 s
Operating Temperature−40 °C to +80 °C
Relative Humidity0–100 % non-condensing
Power Supply12 VDC
Mounting Rod170 mm × 10 mm diameter
Field of View (90% energy acceptance)20°
Housing MaterialBrass with conical reflector and removable quartz window
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP3
Spectral Range300–2800 nm
Output Signal0–55 mV (passive, no power required)
Sensitivity10 µV/W/m² (typical), 5–20 µV/W/m² (range)
Response Time (95%)<18 s
Zero Offset A (thermal)<15 W/m²
Zero Offset B (nighttime cooling)<5 W/m²
Directional Error (up to 80° zenith, 1000 W/m² beam)<20 W/m²
Temperature Dependence of Sensitivity (−10 °C to +40 °C)<4 %
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance2000 W/m²
Field of View180° (2π steradian, hemispherical)
Calibration ComplianceISO 9060:2018 Secondary Standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCMP6
Spectral Range285–2800 nm
Sensitivity5–20 µV/W/m²
Response Time18 s
Zero Offset A< 10 W/m²
Zero Offset B< 4 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 20 W/m²
Temperature Dependence of Sensitivity (−10 °C to +40 °C)< 2 %
Operating Temperature Range−40 °C to +80 °C
Maximum Irradiance2000 W/m²
Field of View180°
Output Signal0–20 mV (passive, no power required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSOLYS2
Tracking Accuracy< 0.1° (passive) / < 0.02° (active with optional sun sensor)
Payload Capacity20 kg
Power Supply18–30 VDC or 90–264 VAC (50/60 Hz)
Operating Temperature−20 to +50 °C (DC) / −40 to +50 °C (AC)
Enclosure MaterialCast aluminum with textured finish
MountingIntegrated tripod base with leveling feet, azimuth adjustment, and bubble level
Communication InterfaceEthernet/Web interface
Drive MechanismInverted-tooth belt drive
Power Consumption21 W (normal), 13 W (night), 100 W (with heater enabled, AC only)
Dimensions (tracker)50 × 34 × 38 cm
Weight (tracker)23 kg
Weight (tripod)5 kg
GPS IntegrationYes, auto-configures latitude, longitude, and UTC time
SoftwareOpen-source firmware
ComplianceBSRN-compliant, designed for ISO 9072-1, ASTM G167, and IEC 61724-1 solar monitoring applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelMETEON 2.0
Storage Capacity3500 samples
Input Channels5 smart + 1 analog radiation sensors + 1 PV panel temperature sensor + 1 S0 kWh pulse input
Power SupplyInternal AA batteries (6)
Environmental RatingWeather-resistant for outdoor deployment
CommunicationUSB, Bluetooth (METEON 2.0)
CompatibilityModbus RTU, analog voltage/current (4–20 mA, 0–1 V, 0–5 V, 0–10 V)
Mounting AccessoriesCVF4 ventilator, CMF1/CMF4 mounts, CMB1 universal mast bracket, CLF4 leveling fixture, AMPBOX signal conditioner, CM121B/C shading ring, anti-glare hood kit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCGR4 / SGR4
Spectral Range (CGR4)4500–42000 nm
Spectral Range (SGR4)4400–50000 nm
Sensitivity5–15 µV/W/m²
Response Time18 s
Window Heating Offset (CGR4)< 4 W/m²
Zero Offset B< 2 W/m²
Temperature Dependence of Sensitivity (−20 to +50 °C)< 1 %
Operating Temperature Range−40 to +80 °C
Net Irradiance Range−250 to +250 W/m²
Field of View180°
Non-linearity Error< 1 %
Analog Output (SGR4)4–20 mA / 0–1 V (mV/W·m²)
Digital Output (SGR4)2-wire RS-485 Modbus®
Power Supply (SGR4)5–30 VDC
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelRT1
Sensor TypeDual-channel digital pyranometer + backsheet temperature probe
MountingCorner-mount compatible with standard PV modules
Calibration Stability±2% uncertainty maintained for 5 years without recalibration
OutputRS-485 (Modbus RTU) or optional analog 4–20 mA
IP RatingIP67
Operating Temperature−40 °C to +80 °C
Dimensions120 × 120 × 45 mm (L × W × H)
Weight320 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP6
Spectral Range300–2800 nm
Response Time (63%)< 1.5 s
Response Time (95%)< 12 s
Zero Offset A< 10 W/m²
Zero Offset B< 4 W/m²
Directional Error (up to 80°, 1000 W/m² beam)±15 W/m²
Temperature Dependence of Sensitivity (−10 °C to +40 °C)< 2 %
Analog Output (-V version)0–1 V
Analog Output (-A version)4–20 mA
Digital Output2-wire RS-485 Modbus® RTU
Operating Voltage5–30 VDC
Integrated Desiccant Lifetime≥10 years
ComplianceISO 9060:2018 Secondary Standard (Class A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP10
Spectral Range285–2800 nm
Response Time (63%)< 0.7 s
Response Time (95%)< 2 s
Zero Offset A< 7 W/m²
Zero Offset B< 2 W/m²
Directional Error (up to 80°, 1000 W/m² beam)< 10 W/m²
Temperature Dependence of Sensitivity (−40 °C to +70 °C)< 0.3 %/°C
Analog Output (-V version)0–1 V
Analog Output (-A version)4–20 mA
Digital Output2-wire RS-485 Modbus®
Operating Voltage5–30 VDC
Integrated Desiccant Cartridge Lifetime≥10 years (sealed operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP3
Spectral Range300–2800 nm
Response Time (63%)< 1.5 s
Response Time (95%)< 12 s
Zero Offset A< 15 W/m²
Zero Offset B< 5 W/m²
Directional Error (up to 80°, 1000 W/m² beam)20 W/m²
Temperature Dependence of Sensitivity (-20 °C to +50 °C)< 2 %
Analog Output (-V version)0–1 V
Analog Output (-A version)4–20 mA
Digital Output2-wire RS-485 Modbus® RTU
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelSMP12
Spectral Range (50% points)285–2750 nm
Response Time (63%)< 0.15 s
Response Time (95%)< 0.5 s
Zero-Offset (thermal offset, full range)< 3 W/m²
Directional Response (1000 W/m² beam irradiance, up to 80° zenith angle)< 10 W/m²
Temperature Dependence of Sensitivity (−10 °C to +40 °C)< 1 %
Temperature Dependence of Sensitivity (−40 °C to +70 °C)< 2 %
Output Interface2-wire RS-485 Modbus® RTU
Supply Voltage10–30 VDC
Surge ProtectionLevel 2 on power input, Level 3 on RS-485 lines
Internal Desiccant Lifetime≥10 years (sealed enclosure)
Integrated Tilt Sensor & Humidity MonitorYes
Calibration Coefficient Stored in MemoryYes
Digital Irradiance OutputDirect in W/m²
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCHP1 / SHP1
Spectral Range200–4000 nm
Sensitivity7–14 µV/W/m²
Response Time (63%)< 5 s (CHP1), < 0.7 s (SHP1)
Response Time (95%)< 2 s (SHP1)
Zero Offset (5 K/h temp. change)< 1 W/m²
Temperature Dependence of Sensitivity< 0.5 % (-20 to +50 °C for CHP1
Field of View5 ± 0.2°
Operating Temperature-40 to +80 °C
Non-linearity Error< 0.2 %
Maximum Irradiance4000 W/m²
ISO 90602018 Classification: Secondary Standard, Spectral Responsivity Class B
Output OptionsCHP1 — 10 kΩ thermistor + Pt-100
Power Supply5–30 VDC (SHP1), polarity-reversal protected
Internal HeatingLow-power, non-interfering with detector thermal stability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelLAS MkII
Aperture10 cm (100–1,000 m path) / 15 cm (250–4,500 m path)
Wavelength850 nm
Scintillation Bandwidth10⁻¹⁷–10⁻¹² m⁻²/³
Power Supply12 VDC, 6 W (up to 54 W with heater enabled)
Dimensions400 × 300 × 240 mm (L×H×D)
Weight8.5 kg
Internal ProcessingCn², sensible heat flux (H), and derived turbulence parameters
Data LoggingOnboard non-volatile memory for multi-month storage
InterfaceRS-232/422 digital, 0–2 V analog output
SoftwareEVATION® (real-time monitoring, post-processing, calibration support)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKipp & Zonen
OriginNetherlands
ModelCSD3
Spectral Range400–1100 nm
Operating Temperature−40 to +70 °C
Sunshine Signal Output1 ± 0.1 V (for direct irradiance > 120 W/m²)
Accuracy>90% (monthly sunshine hours)
Accuracy>90% (clear-sky direct signal)
Analog Output1 mV/(W/m²)
Long-term Drift<2 %/year
Temperature Response<0.1 °C
Response Time<1 ms
Power Supply12 VDC
Built-in HeaterYes
Desiccant IndicatorIntegrated humidity indicator
Cable ConnectorWaterproof IP68-rated mating connector
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare