- All
- Favorite
- Popular
- Most rated
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-190R |
| Measurement Range | 0 to >10,000 μmol·m⁻²·s⁻¹ |
| Spectral Range | 400–700 nm |
| Calibration Uncertainty | ±5% |
| Sensitivity | 5–10 μA per 1000 μmol·m⁻²·s⁻¹ |
| Linearity Error | ≤1% up to 10,000 μmol·m⁻²·s⁻¹ |
| Response Time | <1 μs |
| Temperature Dependence | <0.15%/°C |
| Cosine Response Error | <±1% at 82° zenith angle |
| Operating Environment | −40 to +65°C, 0–100% RH (non-condensing) |
| Detector | Blue-enhanced silicon photovoltaic cell |
| Housing | Anodized aluminum with acrylic diffuser and stainless-steel mounting hardware |
| Dimensions | 2.36 cm Ø × 3.63 cm H |
| Weight | Sensor head: 24 g |
| 2 m cable with base | 60 g |
| Cable Options | 2 m, 5 m, 15 m, 50 m |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK 159 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥ 0.1 mg N |
| Distillation Time | 0–99 min |
| Repeatability | ≤ 1 % |
| Sample Weight Capacity | 10 g |
| Nitrogen Recovery Rate | ≥ 99.5 % |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 416 mm × 385 mm × 780 mm |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK 129 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Determination Range | 0.1–200 mg |
| Distillation Time | 3–5 min per sample |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤5 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2100 W |
| Dimensions (W×D×H) | 385×416×780 mm |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-191R |
| Measurement Range | 0–5000 μmol·s⁻¹·m⁻² (PPFD) |
| Spectral Range | 400–700 nm |
| Calibration Uncertainty | ±10% (NIST-traceable) |
| Sensitivity | 7 μA per 1000 μmol·s⁻¹·m⁻² (typ.) |
| Linearity Error | ≤1% up to 10,000 μmol·s⁻¹·m⁻² |
| Response Time | 10 μs |
| Temperature Dependence | ≤±0.15%/°C |
| Cosine Correction | Acrylic diffuser |
| Azimuthal Error | <±2% at 45° elevation over 360° |
| Spatial Uniformity | ±7% across 1 m length (tested under 2.54 cm incandescent source) |
| Active Area | 1 m × 12.7 mm |
| Operating Environment | −40 to +65 °C, 0–95% RH (non-condensing) |
| Detector | Blue-enhanced silicon photovoltaic cell |
| Housing | Anodized aluminum with acrylic diffuser and stainless steel fasteners |
| Dimensions | 121.3 × 2.54 × 2.54 cm (L×W×D) |
| Weight | 1.4 kg |
| Cable Length | Standard 2 m (5 m optional) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKS20 Pore Water Sampler System |
| Vacuum Controllers | VS-Pro, VacuPorter, VPS-2 |
| Sampling Principle | Suction-based ceramic cup extraction under controlled negative pressure |
| Ceramic Cup Material | Sintered aluminum oxide |
| Cup Dimensions | Ø2 cm × 6 cm |
| Dead Volume | Minimal |
| pH Range | 4–9 |
| Bubble Point | –100 kPa |
| Sampling Rate (Free Water, –50 kPa) | ~5 mL / 10 min |
| Sampling Rate (Sandy Loam, –50 kPa) | ~5 mL / h |
| Vacuum Range (VS-Pro) | 0 to –85 kPa |
| Vacuum Accuracy (VS-Pro) | ±0.05 kPa |
| Power Supply (VS-Pro) | 10.5–15 VDC |
| Current Draw (VS-Pro, Operating) | ~15–16 mA |
| Memory Capacity (VS-Pro) | 5,000 readings |
| Enclosure Rating (VS-Pro) | IP66 |
| Operating Temperature (VS-Pro) | –10 °C to 45 °C |
| VacuPorter Max Vacuum | –85 kPa @ 1 bar |
| VacuPorter Flow Rate | 10 L/min |
| VacuPorter Battery Life | 7 h |
| VPS-2 Max Vacuum | –85 kPa @ 1 bar |
| VPS-2 Displacement | 0.41 L/stroke |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | EMA 502 CHNS-O |
| Measurement Principle | High-Temperature Combustion (CHNS) and Pyrolysis (O) with Gas Chromatography–Thermal Conductivity Detection (GC-TCD) |
| Sample Throughput | Up to 117 samples per run |
| Analysis Time | ≥12 min (CHNS), ≥6 min (O) |
| Detection Method | TCD (no reference gas required) |
| Sample Form | Solid, semi-solid, liquid |
| Max Sample Mass | 100 mg (C-dependent) |
| Calibration Range (He carrier) | C 0.001–20 mg, H 0.001–5 mg, N 0.001–20 mg, S 0.01–6 mg, O 0.005–6 mg |
| Precision (RSD) | ≤0.2% (sulfanilic acid) |
| Operating Temperatures | 1030 °C (CHNS combustion), 1060 °C (O pyrolysis) |
| Carrier Gases | Helium or Argon (Ar for CHN only) |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA, FDA 21 CFR Part 11 (optional) |
| Software | EMASoft™ with LIMS export, Ermes Cloud integration |
| Connectivity | USB, RS232, Wi-Fi/LAN |
| Power | 570 W |
| Dimensions (W×H×D) | 500 × 510 × 410 mm (680 mm H with autosampler) |
| Weight | 45 kg |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-210R |
| Spectral Range | 450–650 nm |
| Output Unit | lux / klux |
| Calibration Uncertainty | ±5% (absolute) |
| Sensitivity | 30 µA per 100 klux (typical) |
| Linearity | ≤1% (up to 100 klux) |
| Response Time | <1 µs |
| Temperature Dependence | ±0.15%/°C |
| Cosine Correction Accuracy | ±1% up to 82° incidence angle |
| Azimuthal Error | <±1% over 360° at 45° elevation |
| Tilt Independence | No orientation-dependent bias |
| Operating Environment | −40 to +65°C, 0–100% RH (non-condensing) |
| Detector | Blue-enhanced silicon photovoltaic cell |
| Housing | Anodized aluminum with acrylic diffuser and stainless steel mounting hardware |
| Dimensions | 2.36 cm Ø × 3.63 cm H |
| Head Mass | 24 g |
| Cable Options | 2 m, 5 m, 15 m, or 50 m |
| Compatible Loggers | LI-1500, LI-250A, 2420 Amplifier, mV Adapter 2003S, Leveling Base 2001S/2003S, Protective Hood |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-7825 |
| Instrument Type | Stable Gas Isotope Ratio Analyzer |
| CO₂ Measurement Range | 50–2000 ppm |
| CO₂ δ¹³C Precision | <0.5 ‰ (1-s avg), <0.04 ‰ (5-min avg) @ 400 ppm |
| CO₂ δ¹⁸O Precision | <0.1 ‰ (5-min avg) @ 400 ppm |
| CO₂ δ¹⁷O Precision | <0.4 ‰ (5-min avg) @ 400 ppm |
| NH₃ Measurement Range | 0–30,000 ppm |
| NH₃ Precision | 2 ppb (1-s avg) @ 300 ppb |
| H₂O Range | 0–60,000 ppm |
| Measurement Technique | Optical Feedback–Cavity Enhanced Absorption Spectroscopy (OF-CEAS) |
| Measurement Frequency | 1 Hz |
| Cavity Volume | 6.41 cm³ |
| Sample Flow Rate | 250 sccm (70 sccm with low-flow accessory) |
| Operating Temperature | −25 °C to +45 °C |
| Operating Humidity | 0–85 % RH (non-condensing, no direct sunlight) |
| Power Consumption | 22 W @ 25 °C |
| Weight | 10.5 kg (with battery) |
| Dimensions (L×H×W) | 51 × 33 × 18 cm |
| Connectivity | Ethernet & Wi-Fi (2.4 GHz, 802.11 a/b/g/n/ac) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK 169 & AutoKJEL |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 1–99 min |
| Repeatability | ≤1% |
| Sample Weight Capacity | 10 g |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (W×D×H) | 385 mm × 416 mm × 780 mm |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA 701/702 |
| Principle | Dumas Combustion Method |
| Detection Limit | NDA 701: 0.003 mg N (He) |
| NDA 702 | 0.001 mg N (He) or 0.01 mg N (Ar) |
| Analysis Time | 3–4 min per sample |
| Repeatability (RSD) | <0.5% using EDTA standard (9.57% N) |
| Sample Weight | 1 g |
| Recovery Rate | >99.5% |
| Power Consumption | 1400 W |
| Dimensions (W×D×H) | 655 × 510 × 410 mm |
| Weight | 54 kg |
| Carrier Gas | He (≥99.999%) or Ar (≥99.999%) |
| Oxygen Supply | O₂ (≥99.999%, 2 bar) |
| Combustion Temperature | 1030 °C |
| Detector | Auto-calibrating Thermal Conductivity Detector (TCD) |
| Throughput | Up to 117 samples (4 × 30-position auto-samplers) |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, EN ISO 16634-1/-2, USP <285>, FDA 21 CFR Part 11 ready (with Ermes software license) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK 139 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Measurement Range | 0.01–100 mg N |
| Distillation Time | 4 min (for 100 mL sample) |
| Repeatability | ≤1% |
| Sample Mass Requirement | ≥0.1 g N |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2100 W |
| Dimensions (W×D×H) | 385 × 416 × 780 mm |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-192 |
| Measurement Range | 400–700 nm |
| Calibration Uncertainty | ±5% (in air) |
| Sensitivity | ~4 µA per 1000 µmol·s⁻¹·m⁻² (underwater) |
| Linearity Error | ≤1% up to 10,000 µmol·s⁻¹·m⁻² |
| Response Time | 10 µs |
| Temperature Dependence | ≤±0.15%/°C |
| Cosine Correction | Optimized for both air and underwater use |
| Azimuthal Error | <±1% at 45° elevation over full 360° |
| Operating Temperature | −40 to +65 °C |
| Pressure Rating | 5500 kPa (equivalent to 560 m depth) |
| Detector | Blue-enhanced, high-stability silicon photovoltaic cell |
| Housing | Corrosion-resistant metal, submersible in freshwater and seawater |
| Dimensions | 3.18 cm Ø × 4.62 cm H |
| Weight | 227 g |
| Cable Options | LI-COR 2222UWB underwater cable (3, 10, 30, 50, or 100 m) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RM.YOUNG 81000RE |
| Pricing | Available Upon Request |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-180 |
| Spectral Range | 380–780 nm |
| Wavelength Resolution | 1 nm (FWHM ≈ 12 nm) |
| Measurement Parameters | PPFD (1–3,000 µmol·m⁻²·s⁻¹), Irradiance (0.5–1,000 W·m⁻²), Illuminance (70–150,000 lx) |
| Detector | CMOS linear image sensor with cosine-corrected optical input |
| Display | 3.5″ 320×420 touchscreen LCD |
| Data Storage | 8 GB SD card (up to 68,000 files) |
| Battery Life | 5 h continuous operation (2500 mAh Li-ion) |
| Accuracy | PPFD ±5%, Illuminance ±5%, Chromaticity (x,y) ±0.0025, CCT ±2%, CRI (Ra) ±1.5% |
| Compliance | JIS C 1609-1:2006 Class AA, DIN 5032-7 Class B |
| Interface | Mini USB 2.0, Wi-Fi SD card, microSD (up to 32 GB) |
| Output Formats | .txt, .jpg |
| Operating Temperature | 0–35 °C |
| Dimensions | 200 × 77 × 26 mm |
| Weight | 0.28 kg |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN 802 |
| Analysis Method | High-Temperature Combustion (1030 °C) |
| Detection Principle | TCD for N, NDIR for C |
| Analysis Time | 3–4 min per sample |
| Sample Weight | Up to 1 g |
| Detection Limits | 0.001 mg N (He), 0.01 mg N (Ar), 0.01 mg C |
| Repeatability (RSD) | ≤0.5% (100 mg EDTA standard) |
| Recovery | >99.5% |
| Carrier Gas | Helium or Argon (99.999% purity, 2 bar) |
| Oxygen Purity | 99.999%, 2 bar |
| Power | 1400 W, 230 V / 50–60 Hz |
| Dimensions (W×H×D) | 655×510×410 mm (655×690×410 mm with autosampler) |
| Weight | 54 kg |
| Compliance | AOAC, AOCS, AACC, ISO, EN, CEN, EPA, IFFO |
| Connectivity | USB, RS232, Wi-Fi/Ethernet to VELP Ermes Cloud Platform |
| Software | CN802 Control & Analysis Suite with GLP-compliant audit trail, real-time graphing, automated C/N ratio calculation, and report generation |
| Origin | USA |
|---|---|
| Manufacturer | METEK GmbH (Germany), Distributed in North America |
| Instrument Type | Imported High-Precision Turbulence-Grade 3D Ultrasonic Anemometer |
| Model | uSonic-3 Cage MP / uSonic-3 Class A MP |
| Sampling Rate | Up to 30 Hz per transducer pair (90 Hz total radial data rate) |
| Wind Speed Range | ±40 m/s |
| Operating Temperature | −40 °C to +60 °C |
| Relative Humidity | 5–100 % RH |
| Wind Accuracy | ±0.5–1 % RMS @ 5 m/s (horizontal, 0°–20° sector) |
| Vertical Velocity Resolution | 0.006 m/s |
| Temperature Resolution | 0.01 K |
| Output Data | 9 radial wind components, 9 sonic temperature values, Cartesian (u, v, w), scalar wind speed & direction, turbulence statistics (with optional module) |
| Communication | RS422, RS485 (300–115.2 kbaud), 10/100 Mbit Ethernet (ASCII protocol, NMEA-compliant framing, checksum support) |
| Power | 10–36 VDC, 2.5 W (heating optional: 10–24 VDC, ≤100 W) |
| Mounting Options | Cage-mount (Cage MP) or Class A meteorological mast mount (Class A MP) |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-193 Spherical Underwater PAR Sensor |
| Measurement Depth | Up to 350 m |
| Spectral Range | 400–700 nm |
| Calibration Uncertainty | ±5% |
| Sensitivity | 7 µA per 1000 µmol·s⁻¹·m⁻² (typ.) |
| Linearity | ±1% deviation up to 10,000 µmol·s⁻¹·m⁻² |
| Long-term Stability | <±2% per year |
| Response Time | 10 µs |
| Temperature Dependence | ≤±0.15%/°C |
| Angular Response Error | <±4% up to ±90° from vertical axis |
| Azimuthal Uniformity | <±3% over full 360° at 90° from vertical |
| Operating Temperature | −40 to +65 °C |
| Pressure Rating | 3400 kPa (equivalent to 350 m seawater depth) |
| Sensor Sphere Diameter | 6.1 cm |
| Base Diameter | 3.18 cm |
| Total Height | 10.7 cm |
| Mass | 142 g |
| Cable Options | Standard 3 m |
| optional lengths | 10, 30, 50, or 100 m (LI-2222UWB submersible cable) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SMS |
| Dimensions | 300 × 500 × 190 mm |
| Weight | 3.5 kg |
| Construction | Epoxy-coated stainless steel |
| Absorption Stages | Three-stage (condensation → alkaline neutralization → activated carbon adsorption) |
| Pump Type | Recirculating water-based absorption pump (JP series) |
| Vacuum Control | Adjustable |
| Optional Accessories | Replacement activated carbon packs (A00001164), activated carbon filter cartridge (A00001165), IQ/OQ validation documentation (A00000252) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm (over full operating temperature range) |
| Detector | Photomultiplier Tube (PMT) |
| Optical Design | Dual Monochromator |
| Power Supply | 230 VAC or 115 VAC |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather housing) |
| Measured Parameters | Total Ozone Column, SO₂ Column, Spectral UV Irradiance (UVA, UVB, UVE), UV Index (UVI) |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ES-2 |
| Measurement Parameter | Single (Electrical Conductivity) |
| Form Factor | Pen-style |
| Deployment Environment | In-pipe, in-tank, and pore-water applications |
| EC Range | 0–120 dS/m |
| TDS Range | Derived from EC (default 0.5–0.7 conversion factor) |
| Resistivity Range | 0.0083–1000 kΩ·cm (calculated inverse) |
| Salinity Range | 0–60 ppt (based on PSS-78 standard) |
| Temperature Range | –40 to +60 °C |
| Accuracy | EC: ±0.01 dS/m or ±10% (whichever is greater) |
| Temp | ±1 °C |
| Resolution | EC: 0.001 dS/m |
| Temp | 0.1 °C |
| Output Protocol | SDI-12 or DDI serial |
| Compatible Data Loggers | METER ZL6 series or any SDI-12–compliant logger with 3.6–15 VDC excitation |
| Dimensions | 10.9 cm (L) × 2.4 cm (W) |
| Cable | 5 m standard (custom up to 75 m) |
| Connector | 3.5 mm stereo jack or tinned leads |
| Power Supply | 3.6–15 VDC |
| Current Draw | 20–28 mA (active), 0.03 mA (standby) |
| Startup Time | 100–250 ms (SDI-12 dependent) |
| Measurement Duration | 25–50 ms |
| Compliance | ISO 9001:2015 certified manufacturing |
| CE marked per EM directive EN ISO/IEC 17050 | 2010 |
| Mechanical Interface | 1-inch NPT threaded body with optional T-fitting for pipe mounting |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-8250 Multi-Channel Automated Soil Greenhouse Gas Flux Measurement System |
| Dimensions | 38.5 cm L × 52 cm W × 18.5 cm H |
| Weight | 7.7 kg |
| Ingress Protection | IP55 |
| Operating Temperature | –20 to 45 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Data Storage | 8 GB internal |
| GPS Accuracy | 2.5 m CEP |
| Maximum Chamber Radius from Unit | 15.0 m (one tube per chamber) |
| Maximum Chamber Diameter Coverage | 30.0 m |
| Pump Flow Rate (chamber-to-unit) | ~2–3 L/min (diaphragm type) |
| Barometric Pressure Sensor Range | 20–110 kPa |
| Accuracy | ±0.4 kPa (50–110 kPa) |
| Resolution | 0.006 kPa |
| Power Input | 10–30 VDC |
| Typical Power Consumption | 4.8 W (standby), 15.6 W (sampling/moving), 18.2 W (peak) |
| Communication | 3× sealed RJ-45 Ethernet, Wi-Fi (2.4 GHz, 802.11 a/b/g/n/ac), USB-A (1 sealed for LI-870, 2 standard), RS-422 output (24 VDC, 115.2 kbps, 1.8 A max/port) |
| Chamber Compatibility | SDI-12–enabled long-term chambers (e.g., 8200-104 / 8200-104C) |
| chamber volume | 3955 cm³ |
| soil measurement area | 317.8 cm² |
| Environmental Sensor Support | Air temperature (±0.3 °C), PAR/light (0–100 µA input, ±0.37% of reading + 8 nA), soil temperature & moisture (via SDI-12) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | UDK 149 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Determination Range | 0.1–200 mg |
| Distillation Time | 3–4 min/sample |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤5 g |
| Nitrogen Recovery Rate | ≥99% |
| Power Consumption | 2100 W |
| Dimensions (W×D×H) | 380 × 416 × 780 mm |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. |
| Model | TEROS 10 |
| Measurement Principle | 70 MHz Frequency Domain Reflectometry (FDR) |
| Output | Analog Voltage (1,000–2,500 mV) |
| VWC Range | 0–64% (soil), 0–70% (non-soil media) |
| Resolution | 0.001 m³/m³ |
| Accuracy | ±0.03 m³/m³ (±3.0% VWC) in mineral soils with EC < 8 dS/m using generic calibration |
| Dielectric Constant Range | 1–80 |
| Accuracy of εₐ | ±1 εₐ (1–40), ±15% of reading (40–80) |
| Operating Temperature | −40 to +60 °C |
| Probe Length | 5.4 cm |
| Housing Dimensions | 5.1 × 2.4 × 7.5 cm (L×W×H) |
| Cable Length | Standard 5 m (custom up to 40 m) |
| Connector | 3.5 mm TRS jack or bare leads |
| Excitation Voltage | 3.0–15.0 VDC |
| Measurement Duration | 10–25 ms |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), EN 61326-1:2013, EN 55022/CISPR 22 |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | TEROS 11 |
| Measurement Principle | 70 MHz Capacitive Dielectric Sensing |
| Output Protocol | SDI-12 / DDI Serial |
| Compliance | ISO 9001:2015, EN 61326-1:2013, EN 55022/CISPR 22, CE Marked per 2014/30/EU & 2011/65/EU |
| Sensor Dimensions | 9.4 × 2.4 × 7.5 cm (L×W×H) |
| Probe Length | 5.5 cm |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Operating Temperature | −40 to +60 °C |
| VWC Range (mineral soil) | 0.00–0.70 m³/m³ |
| VWC Accuracy (generic mineral soil cal) | ±0.03 m³/m³ (EC < 8 dS/m) |
| Temp Accuracy | ±1.0 °C (−40 to 0 °C), ±0.5 °C (0 to 60 °C) |
| Temp Resolution | 0.1 °C |
| VWC Resolution | 0.001 m³/m³ |
| Dielectric Range | 1–80 (εₐ) |
| Frequency | 70 MHz |
| Power Supply | 4.0–15.0 VDC |
| Sleep Current | ~0.03 mA |
| Active Current (25 ms) | 3.0–16.0 mA |
| Interface | 3.5 mm TRS or bare-wire termination |
Show next