Empowering Scientific Discovery

Beijing Lijia United Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell
OriginUSA
ModelEC150
Measurement PrincipleOpen-path infrared absorption (CO₂/H₂O) + ultrasonic anemometry (3D wind, sonic temperature)
Output FrequencyUp to 60 Hz
Bandwidth20 Hz
Power ConsumptionLow-power design suitable for solar-powered operation
Environmental RatingOutdoor-rated, rain-resistant housing with hydrophobic mesh and angled optical windows
CalibrationFactory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges
CompatibilityNative integration with Campbell Scientific dataloggers (CR6, CR1000X, etc.) for configuration, zero/span adjustment, diagnostics, and real-time data streaming
Diagnostic CapabilitiesComprehensive internal diagnostics including signal strength, window contamination index, path alignment status, and transducer health monitoring
ComplianceDesigned to meet field requirements for FLUXNET, AmeriFlux, ICOS, and other long-term eddy covariance networks adhering to AmeriFlux/ICOS Best Practices and ISO 17025 traceable calibration protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
OriginUSA
ModelCS320
Sensor TypeThermopile-based Total Solar Radiation Sensor
Calibration Uncertainty±5%
Measurement Range0–2000 W/m²
Repeatability<1%
Long-term Drift<2% per year
Non-linearity<1%
Spectral Range385–2105 nm
Field of View180° (hemispherical)
Response Time2 s
Temperature Dependence<5% over −15 to +45 °C
Operating Temperature−50 to +50 °C
Heating Power0.2 W
Supply Voltage6–24 VDC
Current Consumption5 mA (during measurement)
Output ProtocolSDI-12 digital interface
Sensor Diameter34.3 mm
Height39.6 mm
Mass64.9 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
OriginUSA
ModelCSAT3
Measurement PrincipleUltrasonic Time-of-Flight (TOF) in Three Orthogonal Axes
Vertical Path Length10 cm
Output FrequencyUp to 50 Hz
Output OptionsAnalog (±5 V) and Digital (SDM, RS-232)
Operating Temperature Range–30°C to +50°C
Ingress ProtectionIP66-rated enclosure
ComplianceDesigned for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols
Integrated ClockInternal temperature-compensated crystal oscillator (TCXO), ±1 ppm stability over operating range
SynchronizationSDM-compatible for precise multi-sensor timing alignment