| [Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 200 |
| Product Type | Discrete Flow Analyzer |
| Measurement Speed | 200 samples/hr |
| Sample Capacity | 5 racks × 126 positions |
| Reaction Temperature | 37.2 °C ± 0.1 °C |
| Optical Range | 420–880 nm |
| Absorbance Linearity | 0.001–2.500 AUFS |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 300 µL |
| Pipetting Range | 3–450 µL |
| Dilution Factor | Up to 100× |
| Reagent Positions | 16 (10 refrigerated + 6 ambient) |
| Standard Positions | 10 |
| Diluent Positions | 2 |
| Filter Wheel | 9 optical filters + 1 blank filter |
| Reaction Cuvettes | 60-position rotating disc, semi-reusable, auto-cleaned and QC-verified |
| Compliance | ASTM, ISO, AOAC, US EPA Method 353.2 (NO₃⁻/NO₂⁻), AFNOR, COFRAC, BATF, USEPA] |
| [Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Smartchem 300 |
| Pricing | Available Upon Request |
| Analysis Types | End-point, Kinetic, Differential, Dual-wavelength, Fixed-time |
| Reagent Positions | Up to 72 positions with refrigeration (4 movable racks × 16 slots + 8 fixed slots |
| Sample Positions | 4 universal sample carousels (15 positions each for cups or tubes Ø10–16 mm × 40–100 mm H) |
| Throughput | Up to 450 samples/h (with ISE module), 300 samples/h (photometric only) |
| Photometer | Dual-channel, direct-read, 9-position auto-select narrow-band interference filters (340–880 nm), 6 V/10 W halogen lamp, 6 mm pathlength, linear range 0.001–4.200 Abs, resolution 0.0001 Abs |
| Minimum Reaction Volume | 200 µL |
| Sample/Reagent Dispensing | Capacitive microdispenser, 3.0 µL–330 µL (1 µL increment), 37 °C reagent preheating, integrated probe washing, on-board dilution capability |
| Reaction Cuvettes | 80 reusable quartz/glass cuvettes across 4 independent rotating carousels (20 per carousel), automated cleaning with selectable acidic/alkaline/neutral wash solutions, temperature control at 37 °C ± 0.3 °C |
| Nitrate/Nitrite Module | Fully compliant with US EPA Method 353.2 |
| Optional ISE Module | Direct potentiometric measurement of Na⁺, K⁺, Cl⁻, Li⁺ (140 samples/h) |
| Barcode Scanning | Optional reagent and sample tube barcode readers |
| Compliance | ISO, AOAC, BATF, US EPA, AFNOR, COFRAC] |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem 300 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SMARTCHEM 140 |
| Pricing | Available Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smartchem |
| Pricing | Upon Request |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | Smartchem600 |
| Product Type | Discrete Analyzer |
| Wavelength Range | 12 fixed wavelengths from 340 to 880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Path Length | 6 mm or 10 mm |
| Light Source | High-stability LED |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Futura |
| Pricing | Upon Request |
| Brand | AMS |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | FUTURA Segmented Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | 240–720 positions |
| Reagent Positions | 5–30 |
| Flow Cell Path Length | 5–500 mm |
| Light Source | Tungsten-Halogen Lamp |