- All
- Favorite
- Popular
- Most rated
| Brand | Campbell |
|---|---|
| Origin | USA |
| Model | EC150 |
| Measurement Principle | Open-path infrared absorption (CO₂/H₂O) + ultrasonic anemometry (3D wind, sonic temperature) |
| Output Frequency | Up to 60 Hz |
| Bandwidth | 20 Hz |
| Power Consumption | Low-power design suitable for solar-powered operation |
| Environmental Rating | Outdoor-rated, rain-resistant housing with hydrophobic mesh and angled optical windows |
| Calibration | Factory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges |
| Compatibility | Native integration with Campbell Scientific dataloggers (CR6, CR1000X, etc.) for configuration, zero/span adjustment, diagnostics, and real-time data streaming |
| Diagnostic Capabilities | Comprehensive internal diagnostics including signal strength, window contamination index, path alignment status, and transducer health monitoring |
| Compliance | Designed to meet field requirements for FLUXNET, AmeriFlux, ICOS, and other long-term eddy covariance networks adhering to AmeriFlux/ICOS Best Practices and ISO 17025 traceable calibration protocols |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | X-LAS MkII / 160 GHz Microwave Scintillometer Integrated System |
| Path Length | 500 m – 10 km |
| Operating Frequency | 160.8 GHz (λ = 1.86 mm) |
| Transmit Power | >25 mW (with 50 dB attenuator) |
| Detection Bandwidth | 10 kHz |
| Power Supply | 12 VDC, max 50 W per unit (Rx: 20 W typ, Tx: 15 W typ) |
| Receiver Aperture | 300 mm |
| Dimensions (Rx) | 482.5 × 360 × 363 mm, 12 kg |
| Dimensions (Tx) | 482.5 × 360 × 363 mm, 10 kg |
| Data Output | Fiber-optic interface (to fiber-to-LAN converter), GPS-synchronized timestamping, VGA/USB×2/sub-D service port |
| Software | Integrated scintillation data acquisition, synchronization, and eddy-covariance–compatible flux computation |
| Brand | Rinntech |
|---|---|
| Origin | Germany |
| Model | LIGNOSTATION |
| Radiation Source | High-Frequency Electromagnetic Sensor (Non-Ionizing) |
| Max Sample Length | 500 mm |
| Spatial Resolution | ≤ 20 µm |
| Imaging Modality | Dual-Mode (Electromagnetic Density Scanning + Optical Micro-Photography) |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible workflow support |
| Preprocessing Integration | Integrated surface trimming and polishing capability |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | SoilVUE10 |
| Measurement Principle | Time-Domain Reflectometry (TDR) |
| Output Protocol | SDI-12 v1.4 |
| Depth Options | 0.5 m (6 depth layers) or 1.0 m (9 depth layers) |
| Diameter | 5.2 cm (body), 5.8 cm (with threads) |
| Length | 0.55 m (0.5 m version) / 1.05 m (1.0 m version) |
| Weight | 1.9 kg / 3.6 kg |
| Operating Temperature | −30 °C to +40 °C |
| Volumetric Water Content Accuracy | ±1.5% (for most mineral soils) |
| Electrical Conductivity Range | 0–10 dS/m |
| Relative Permittivity Range | 1–80 |
| Relative Permittivity Accuracy | ±1 unit |
| Temperature Accuracy | ±0.15 °C |
| Power | ~64 mA dynamic / ~2.5 mA quiescent @ 12 VDC |
| IP Rating | IP67 (M12 connector) |
| Compliance | SDI-12 v1.4, RoHS, CE |
| Brand | YSI |
|---|---|
| Origin | USA |
| Housing Rating | NEMA 6P / IP68 |
| Construction Materials | 316 Stainless Steel or Titanium Alloy |
| Memory Capacity | 2 MB or 4 MB |
| Data Storage Capacity | Up to 600,000 records (water level, temperature, timestamp) |
| Water Level Range | up to 210 m |
| Accuracy | ±0.05% of full scale (for water levels > 3 m) |
| Pressure Reference Options | Ventilated (gauge) or Non-ventilated (absolute) with optional integrated barometer |
| Battery Life | Up to 3 years (field-replaceable) |
| Sampling Modes | Linear, Linear-Averaged, Event-Triggered, Logarithmic |
| Operating Temperature Range | –20 °C to +50 °C |
| External Diameter | 1.9 cm |
| Firmware Upgrade | Field-upgradable via USB or serial interface |
| Software | YSI DataScout (Windows-based, supports ASTM D4044, ISO 14001-aligned data handling, FDA 21 CFR Part 11-compliant audit trail in licensed version) |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CS320 |
| Sensor Type | Thermopile-based Total Solar Radiation Sensor |
| Calibration Uncertainty | ±5% |
| Measurement Range | 0–2000 W/m² |
| Repeatability | <1% |
| Long-term Drift | <2% per year |
| Non-linearity | <1% |
| Spectral Range | 385–2105 nm |
| Field of View | 180° (hemispherical) |
| Response Time | 2 s |
| Temperature Dependence | <5% over −15 to +45 °C |
| Operating Temperature | −50 to +50 °C |
| Heating Power | 0.2 W |
| Supply Voltage | 6–24 VDC |
| Current Consumption | 5 mA (during measurement) |
| Output Protocol | SDI-12 digital interface |
| Sensor Diameter | 34.3 mm |
| Height | 39.6 mm |
| Mass | 64.9 g |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CSD3 |
| Spectral Range | 400–1100 nm |
| Operating Temperature | -40 to +70 °C |
| Sunshine Signal Output | 1 ± 0.1 V (for direct irradiance > 120 W/m²) |
| Accuracy | >90% (monthly sunshine hours) |
| Accuracy | >90% (clear-sky direct signal) |
| Analog Output | 1 mV/(W/m²) |
| Long-term Drift | <2 %/year |
| Thermal Response | <0.1 °C |
| Response Time | <1 ms |
| Power Supply | 12 VDC |
| Integrated Heater | Yes |
| Desiccant Indicator | Visual humidity indicator |
| Connector | Waterproof M12 plug/socket |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | O2S-F |
| Pricing | Available Upon Request |
| Diffusion-Type (D) | Height 1.375", Diameter 1.375", Mesh Size 125 |
| Flow-Through Type (F) | Length 3.5 cm, Diameter 3.5 cm, Tubing Port 1/8" NPT |
| Output (D/F) | ~50 mV at 20.95% O₂ (D), ~12 mV at 20.95% O₂ (F) |
| Lifetime | >10 years continuous (D), >5 years continuous (F) |
| Response Time (t₉₀) | 60 s (D), 12 s (F) |
| Measurement Range | 0–100% O₂ |
| Accuracy Drift | <0.01% O₂/day |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Operating Temperature | 0–50 °C |
| Power Supply | 12 V for heater (TM variant), 5 V excitation for thermistor (TM) |
| Sensor Dimensions | Ø3.15 cm × 6.85 cm |
| Weight | 175 g |
| Standard Cable | 3 m (extendable) |
| Soil-Compatible Variant | O2S-S |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | CNR4 |
| Spectral Range (Shortwave) | 300–2800 nm |
| Spectral Range (Longwave) | 4500–42000 nm |
| Sensitivity | 5–20 µV/W/m² |
| Temperature Dependence of Sensitivity (−10 to +40 °C) | < 4 % |
| Response Time | < 18 s |
| Non-linearity Error | < 1 % |
| Operating Temperature Range | −40 to +80 °C |
| Ventilation Power (Optional CNF4) | 10 W |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CPEC200 |
| Operating Temperature | −30 °C to +50 °C |
| Input Voltage | 10.5–16.0 Vdc |
| Typical Power Consumption | 12 W (max 35 W cold start) |
| System Dimensions | 52.1 × 44.5 × 29.7 cm |
| System Weight | 11.6 kg |
| Pump Module Flow Rate | 3–9 LPM (typ. 7 LPM) |
| Pump Pressure Range | 15–115 kPa |
| Valve Modules | 3-valve (zero, CO₂ span, H₂O span) or 6-valve (zero, four CO₂ spans, one H₂O span) |
| Data Storage | 2 GB CompactFlash card (≥60 days at 10 Hz) |
| Communication Interfaces | Ethernet, RS-232, short-haul modem, cellular, radio, satellite |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ADV |
| Pricing | Upon Request |
| Operating Frequencies | 16 MHz (MicroADV), 10 MHz (ADV), 5 MHz (ADVOcean) |
| Sampling Rates | 0.1–50 Hz (MicroADV), 0.1–25 Hz (ADV & ADVOcean) |
| Sample Volume | 0.09 cm³ (MicroADV), 0.25 cm³ (ADV), 2.0 cm³ (ADVOcean) |
| Transducer-to-Sample Distance | 5 cm (MicroADV & ADV), 18 cm (ADVOcean) |
| Velocity Resolution | 0.01 cm/s |
| Accuracy | ±1% of measured velocity or ±0.25 cm/s, whichever is greater |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | IRGASON |
| Measurement Principle | Simultaneous open-path infrared absorption (CO₂/H₂O) and ultrasonic anemometry (3D wind velocity, sonic temperature) |
| Output Frequency | Up to 60 Hz |
| Bandwidth | 20 Hz |
| Power Consumption | Low-power design compatible with solar power systems |
| Environmental Rating | IP65-rated enclosure |
| Calibration | Factory-calibrated for CO₂, H₂O, air temperature, barometric pressure, and sonic temperature across wide operational ranges |
| Diagnostic Capabilities | Comprehensive real-time diagnostics including signal strength, window contamination status, transducer health, and acoustic path integrity |
| Data Compatibility | Native support for Campbell Scientific CR series dataloggers (e.g., CR6, CR1000X) with full integration of setup, zero/span adjustment, and configuration via direct serial or SDI-12 interface |
| Rain Mitigation | Patented hydrophobic mesh + adaptive ultrasonic signal processing to maintain wind vector accuracy during precipitation |
| Optical Design | Angled optical windows with anti-water-adhesion geometry and tolerance for mild surface contamination |
| Thermal Management | Passive temperature compensation—no active heater required |
| Brand | KIPP ZONEN |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RaZON+ Integrated Solar Monitoring System |
| Pricing | Available Upon Request |
| Tracking Accuracy | 0.2° (Passive) / <0.02° (Active with Optional Sun Sensor) |
| Power Supply | 24 V DC |
| Operating Temperature Range | -20 °C to +50 °C |
| Ingress Protection Rating | IP65 |
| Drive Mechanism | Gear-Driven |
| Communication Interfaces | RS-485 (Modbus® RTU/ASCII), Ethernet (RJ-45), Wi-Fi (Web-Based Interface) |
| Data Processing Interval | 1-minute Averaging |
| Detector Material | Fused Quartz (for Both DNI and DHI Sensors) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SF-3000 |
| Quotation | Upon Request |
| Control Channels | 8 or 16 |
| Operating Temperature (Controller) | −25 to +55 °C |
| Relative Humidity Range | 0–95% RH |
| Communication Interface | RS-232 (26-pin aviation connector) |
| Baud Rate | 9600 bps |
| Sensor Interface | SDI-12 (5-pin aviation connector) |
| SDI-12 Ports | 8 (expandable to 62 sensors) |
| Data Storage | USB 1.1 Full-Speed (USB 2.0 compatible) |
| Power Input | 12 VDC ±10%, ≥3 A |
| Power Output | 12 VDC ±10%, ≤1.1 A per channel |
| Enclosure Dimensions (Controller) | 16.2 × 40.7 × 28.5 cm, 5.9 kg |
| Flux Chamber Dimensions | 24 × 28 × 45 cm, 6.0 kg |
| Chamber Volume | 3100 cm³ |
| Chamber Footprint Area | 314 cm² |
| Chamber Actuation | Pneumatic (external cylinder) |
| Barometric Pressure Range | 15–115 kPa, ±1.5% accuracy |
| Chamber Temperature Range | −20 to +50 °C |
| Temperature Sensor Accuracy | ±0.5 °C |
| Brand | KIPP & ZONEN |
|---|---|
| Origin | Netherlands |
| Model | CMP22 Pyranometer |
| Spectral Range | 200–3600 nm |
| Sensitivity | 7–14 µV/W/m² |
| Response Time (95%) | 5 s |
| Zero-Offset A (thermal, 5 K/h) | < 3 W/m² |
| Zero-Offset B (nighttime, 200 W/m² net IR) | < 1 W/m² |
| Directional Error (up to 80° zenith, 1000 W/m² beam) | < 5 W/m² |
| Temperature Dependence of Sensitivity (−20 °C to +50 °C) | < 0.5 % |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 4000 W/m² |
| Field of View | 180° (2π steradian) |
| Dome Material | High-Purity Fused Quartz |
| Integrated Level | Top-Mounted Bubble Vial |
| Desiccant System | Threaded Desiccant Cartridge with Refill Kit Included |
| Cable | Yellow UV-Stable PVC Cable with IP68 Waterproof Connector (pre-wired lengths optional) |
| Brand | Picarro |
|---|---|
| Origin | USA |
| Model | G5310 |
| Measurement Principle | Cavity Ring-Down Spectroscopy (CRDS) |
| Target Gases | Nitrous Oxide (N₂O), Carbon Monoxide (CO), Water Vapor (H₂O) |
| Detection Limits | <0.2 ppb (N₂O, 5 s), <0.2 ppb (CO, 5 s), <40 ppm (H₂O, 5 s) |
| Accuracy (5 min) | <0.04 ppb (N₂O & CO), <6 ppm (H₂O) |
| Drift (24 h) | <0.1 ppb (N₂O & CO), typical = 0.036–0.046 ppb |
| Measurement Range | 1–1500 ppb (N₂O), 1–1500 ppb (CO), 0–3% (H₂O) |
| Sample Flow Rate | 100 sccm |
| Temperature Control Stability | ±0.005 °C |
| Pressure Control Stability | ±0.0002 atm |
| Operating Ambient | 15–35 °C, <85% RH (non-condensing) |
| Dimensions | 43.2 × 31.7 × 52.1 cm (W×H×D) |
| Weight | 43 kg |
| Power | 100–240 VAC, 47–63 Hz, 200 W (operational) |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SP Lite2 Pyranometer |
| Spectral Range | 400–1100 nm |
| Sensitivity | 60–100 µV/W/m² |
| Response Time (95%) | < 500 ns |
| Directional Error (up to 80°, 1000 W/m² beam) | < 10 W/m² |
| Temperature Response | < −0.15 %/°C |
| Operating Temperature Range | −40 °C to +80 °C |
| Maximum Irradiance | 2000 W/m² |
| Field of View | 180° |
| Output | Analog voltage (mV), calibrated for direct conversion to W/m² |
| Brand | KIPP&ZONEN |
|---|---|
| Origin | Netherlands |
| Model | LAS MkII Large-Aperture Scintillometer |
| Aperture Options | 10 cm (path range: 100 m – 1 km) / 15 cm (path range: 250 m – 4.5 km) |
| Operating Wavelength | 850 nm |
| Scintillation Bandwidth | 10⁻¹⁷ – 10⁻¹² m⁻²/³ |
| Power Supply | 12 VDC, 6 W (max 54 W with heater enabled) |
| Dimensions | 400 × 300 × 240 mm (L×H×D) |
| Weight | 8.5 kg |
| Internal Processing | Cn², sensible heat flux (H), and derived turbulence parameters |
| Data Logging | Onboard non-volatile memory for multi-month storage |
| Interface | RS-232/422 digital, 0–2 V analog output |
| Software | EVATION® (real-time monitoring, post-processing, compliance-ready export) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | 907-0010, 908-0010, 911-0010, 907-0011, 908-0011, 911-0011 |
| Pricing | Upon Request |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AP200 |
| Pricing | Upon Request |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CPEC310 |
| Operating Temperature Range | −30 °C to +50 °C |
| Input Voltage | 10.5–16.0 V DC |
| Typical Power Consumption | 12 W |
| Max Power (Cold Start) | 35 W |
| Sample Cell Volume | 5.9 mL |
| Sample Residence Time | 50 ms @ 7 L/min |
| Frequency Response (−3 dB) | 5.8 Hz (CO₂/H₂O) |
| Cut-off Frequency (System) | 4.3 Hz |
| Pump Flow Rate | 3–9 L/min (Auto-Controlled, Default: 7 L/min) |
| Pressure Sensor Range | 15–115 kPa |
| Enclosure Dimensions (Control Box) | 54 × 44.5 × 29.7 cm |
| Weight (Control Box) | 15.36 kg (16.24 kg w/ CDM-A116) |
| Pump Module Dimensions | 35.6 × 29.2 × 13.5 cm |
| Weight (Pump Module) | 5.4 kg |
| Three-Valve Module Dimensions | 14.0 × 12.7 × 14.0 cm |
| Weight | 1.5 kg |
| Scrubber Module Heater Power | 8 W |
| Molecular Sieve Bead Size | 1.6–2.5 mm |
| Scrubber Cylinder Volume | 480 cm³ |
| Brand | Campbell Scientific |
|---|---|
| Origin | USA |
| Model | CSAT3 |
| Measurement Principle | Ultrasonic Time-of-Flight (TOF) in Three Orthogonal Axes |
| Vertical Path Length | 10 cm |
| Output Frequency | Up to 50 Hz |
| Output Options | Analog (±5 V) and Digital (SDM, RS-232) |
| Operating Temperature Range | –30°C to +50°C |
| Ingress Protection | IP66-rated enclosure |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Integrated Clock | Internal temperature-compensated crystal oscillator (TCXO), ±1 ppm stability over operating range |
| Synchronization | SDM-compatible for precise multi-sensor timing alignment |
| Brand | Palas |
|---|---|
| Origin | Germany |
| Model | Fidas 200 |
| Certification | EN 16450-compliant |
| Measurement Principle | Single-particle optical aerosol spectrometry (OPC) |
| PM Metrics | Simultaneous real-time PM₂.₅ and PM₁₀ mass concentration |
| Particle Count & Size Distribution | 18 size channels from 0.17–19.2 µm |
| Time Resolution | Adjustable from >1 s to 24 h |
| Light Source | High-stability, long-life LED |
| Data Availability | >99% uptime |
| Compliance | EN 15267-3 type approval, EN 16450 reference equivalent |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | Brewer MkIII Spectrophotometer |
| Measurement Principle | Double-monochromator UV spectrophotometry with PMT detection |
| Wavelength Range | 286.5–363 nm |
| Spectral Resolution | 0.6 nm |
| Wavelength Stability | ±0.01 nm over full operating temperature range |
| Power Supply | 230 VAC or 115 VAC / Optional DC input |
| Operating Temperature | −20 °C to +50 °C (−50 °C to +50 °C with optional cold-weather enclosure) |
| Measured Parameters | Total Ozone Column (TOC), SO₂ Column, Spectral UV Irradiance (286.5–363 nm), UVA (315–400 nm), UVB (280–315 nm), UVE (250–260 nm), UV Index (UVI) |
| Compliance | Designed to meet WMO/GAW reference instrument requirements for ground-based UV and ozone monitoring |
| Sample Compatibility | Direct solar irradiance (direct sun, zenith sky, and diffuse sky modes) |
| Software Interface | PC-based control with 24/7 autonomous operation capability, remote telemetry support |
Show next