BrandPicarro
OriginUSA
ModelG2307
PortabilityPortable
Response Time< 5 s
RepeatabilityH₂CO, CH₄, and H₂O
Measurement PrincipleCavity Ring-Down Spectroscopy (CRDS)
Detection Limits (3σ, 300 s)0.18 ppb (H₂CO), 0.3 ppb (CH₄)
Long-Term Drift (24 h, STP)1.5 ppb (H₂CO)
Temperature Control Stability±0.005 °C
Pressure Control Stability±0.0002 atm
Sample Flow Rate~400 sccm at 760 Torr
Operating Temperature Range10–35 °C
Dimensions (Analyzer)43.2 × 17.9 × 44.6 cm
Weight (Analyzer)21.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPicarro
OriginUSA
ModelG4301
PortabilityPortable
Response Time5 s
RepeatabilityCO₂, CH₄, H₂O
Measurement PrincipleCavity Ring-Down Spectroscopy (CRDS)
Power Consumption25 W
Battery LifeUp to 8 h
Dimensions35.6 × 17.7 × 46.4 cm
Weight10.4 kg
Operating Temperature10–45 °C
Relative Humidity<85% non-condensing
Sample Flow Rate~1 SLPM
Detection Limits (3σ, 300 s)CO₂: 0.12 ppm, CH₄: 0.9 ppb, H₂O: N/A
Accuracy (5 s)CO₂: 0.4 ppm + 0.1% of reading, CH₄: 3 ppb + 0.1% of reading, H₂O: 100 ppm + 5% of reading
Drift (24 h)CO₂: 0.5 ppm (typ. 0.18 ppm), CH₄: 1 ppb (typ. 0.56 ppb)
Measurement RangeCO₂: 0–3%, CH₄: 0–800 ppm, H₂O: 0–3% (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPicarro
OriginUSA
ModelG2508
Instrument PrincipleCavity Ring-Down Spectroscopy (CRDS)
TypeBenchtop / Portable Configurable System
Response Time< 8 s (10–90% rise/fall)
RepeatabilityN2O/CH4/CO2/NH3/H2O
Measurement SensitivitySub-ppb for N2O, CH4, CO2, NH3
Operating Environment10–35 °C, <85% RH (non-condensing)
Sample Pressure300–1000 Torr (40–133 kPa)
Sample Flow Rate~230 sccm
Cavity Temperature Stability±0.005 °C
Cavity Pressure Stability±0.0002 atm
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model915-0011
Response Time1 s
RepeatabilityCH₄ < 0.25 ppb (100 s), CO₂ < 40 ppb (100 s), H₂O < 15 ppm (100 s)
Measurement PrincipleCavity Ring-Down Spectroscopy (CRDS)
Form FactorPortable
Power Consumption60 W (DC), 66 W (AC)
Dimensions17.8 cm H × 47 cm W × 35.6 cm D
Weight15 kg
Operating Temperature5–45 °C
Sample Temperature Range−10–50 °C
Relative Humidity0–100% RH (non-condensing)
Detection Limits (1σ, 100 s)CH₄: 0.25 ppb, CO₂: 40 ppb, H₂O: 15 ppm
Full-Scale Linear RangeCH₄: 0.01–100 ppm (extendable to 10% vol), CO₂: 1–20,000 ppm, H₂O: 500–70,000 ppm (0–100% RH)
Data OutputRS-232, Analog, Ethernet, USB
Accuracy<1% uncertainty (uncalibrated, 10–35 °C)
Sampling Rate0.01–1 Hz