Empowering Scientific Discovery

Beijing Lijia United Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAPOGEE
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model Numbers907-0038 (Standard Rackmount), 911-0038 (Enhanced Precision EP), 915-0038 (Ultra-Portable)
Measurement PrincipleOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS)
Detection Limits0.2 ppb (HCl & HF, 1σ, 100 s)
Precision (1σ)2 ppb (5 s), 0.2 ppb (100 s)
Drift (24 h, STP, EP model)≤1 ppb
Measurement Range (full-spec)0.2–2000 ppb
Optional Extended Range0–10 ppm
Response Time (flow-limited)<6 s
Data OutputRS-232, Analog, Ethernet, USB
Power115/230 VAC, 50/60 Hz or 12 VDC
Power Consumption100 W (Standard), 150 W (EP)
Operating Temperature0–45 °C
Sample Temperature Range–10 to +80 °C
Relative Humidity0–100 % RH (non-condensing)
Dimensions & WeightStandard: 22.2 × 48.3 × 61 cm, 29.5 kg
EP35.6 × 48.3 × 61 cm, 40.8 kg
Ultra-Portable17.8 × 47 × 35.6 cm, 19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
ManufacturerLos Gatos Research
TypeOA-ICOS-based Ambient NO₂ Monitor
Models907-0009 (Rack-Mount Standard), 908-0009 (Benchtop Standard), 911-0009 (Enhanced Performance Rack-Mount)
Detection Limit0.05 ppb (1σ, 60 s)
Precision50 ppt (1σ, 1 s)
Response Time (Cavity Flush)10 s (Internal Pump) / 1 s (Optional External Vacuum Pump)
Drift≤50 ppt (24 h, EP model, STP, 15-min avg)
Measurement Range0.01–1000 ppb (full-spec)
Optional Extended Range0–3000 ppb
LinearityFull-scale linear
Zero CalibrationAuto-zero via metal oxide scrubber (no zero gas required)
Sample Temp.0–50 °C
Operating Temp.5–45 °C
Humidity0–100% RH (non-condensing)
Power115/230 VAC, 50/60 Hz, 100 W (Std) / 150 W (EP)
Dimensions & WeightBenchtop Std: 25.4 × 96.5 × 35.6 cm, 27 kg
Rack Std22.2 × 48.3 × 61 cm, 27 kg
Rack EP35.6 × 48.3 × 61 cm, 40 kg
OutputsRS-232, Analog (0–10 V / 4–20 mA), Ethernet, USB
Internal Data StorageLinux-based embedded computer with HDD logging
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model Numbers907-0017 (Standard Rackmount), 911-0017 (Enhanced Precision), 915-0017 (Ultra-Portable)
Detection PrincipleOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS)
Measurement TargetHydrogen Fluoride (HF) and Water Vapor (H₂O)
Detection Limit0.1 ppb (1σ, 100 s)
Precision1 ppb (1σ, 1 s) / 0.1 ppb (1σ, 100 s)
Drift≤0.1 ppb (24 h, EP model, STP, 15-min avg)
Measurement Range0.1–2000 ppb (standard)
Response Time<10 s (with optional external pump)
Data OutputRS-232, Analog, Ethernet, USB
Power115/230 VAC, 50/60 Hz or 12 VDC
Power Consumption100 W (Standard), 150 W (EP), 70 W (Ultra-Portable)
Operating Temperature0–45 °C
Sample Temperature0–50 °C
Relative Humidity0–100% RH (non-condensing)
Dimensions & WeightStandard: 22.2 × 48.3 × 61 cm, 29 kg
EP35.6 × 48.3 × 61 cm, 40 kg
Ultra-Portable17.8 × 47 × 35.6 cm, 19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Models907-0037 (Standard Rackmount), 911-0037 (Enhanced Precision), 915-0037 (Ultra-Portable)
Repeatability (1σ)2 ppb (1 s), 0.2 ppb (100 s)
Max Drift (EP, 15-min avg, STP, 24 h)1 ppb
Measurement Range (full spec compliance)0.2–2000 ppb
Optional Range0–30 ppm
Measurement Rate0.01–1 Hz (flow response <10 s requires optional external pump)
Sample Temp0–50 °C
Operating Temp0–45 °C
Humidity0–100% RH (non-condensing)
OutputsRS-232, Analog, Ethernet, USB
Power115/230 VAC, 50/60 Hz or 12 VDC
Power Consumption100 W (Standard), 150 W (EP), 70 W (Ultra-Portable)
Dimensions & WeightStandard: 22.2 × 48.3 × 61 cm, 29 kg
EP35.6 × 48.3 × 61 cm, 40 kg
Ultra-Portable17.8 × 47 × 35.6 cm, 19 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPicarro
OriginUSA
ModelG2401
Instrument TypePortable
Measured GasesCO, CO₂, CH₄, H₂O
Response Time< 5 s
Measurement Precision (1σ, 5 s)CO < 15 ppb, CO₂ < 50 ppb, CH₄ < 1 ppb, H₂O < 30 ppm
Measurement RangeCO: 0–1000 ppm, CO₂: 0–5 ppm, CH₄: 0–20 ppm, H₂O: 0–7%
Accuracy ComplianceMeets WMO GAW and ICOS atmospheric monitoring requirements for CO, CO₂, and CH₄
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Models908-0016 (Benchtop), 907-0016 (Rackmount Standard), 911-0016 (Rackmount EP), 915-0016 (Ultra-Portable)
Power115/230 VAC, 50/60 Hz, 120 W (Standard) / 150 W (EP)
Dimensions & WeightBenchtop: 25.4 × 96.5 × 35.6 cm, 29.5 kg
Rackmount Standard22.2 × 48.3 × 61 cm, 29.5 kg
Rackmount EP35.6 × 48.3 × 61 cm, 40.5 kg
Ultra-Portable17.8 × 47 × 35.6 cm, 19 kg
Measurement Range (NH₃)1–10,000 ppb (full-spec)
H₂O Range0–60,000 ppm (non-condensing)
Precision (1σ)0.6 ppb (10 s), 0.2 ppb (100 s), 0.12 ppb (300 s)
Max Drift (EP, 24 h, STP)0.2 ppb
Temp. Control Stability (EP)±0.003 °C
Pressure Control Stability (EP)±0.001 torr
Sampling Rate0.01–1 Hz (user-selectable)
Operating Temp.5–45 °C (Standard), 0–45 °C (EP)
Sample Temp.0–50 °C
Humidity0–100% RH (non-condensing)
OutputsRS-232, Analog, Ethernet, USB
Detection PrincipleOff-Axis Integrated Cavity Output Spectroscopy (OA-ICOS)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0