BrandNC Technologies
OriginItaly
ModelECS 8024 Soil-Specific CN Elemental Analyzer
Measurement PrincipleDumas combustion coupled with gas chromatographic separation
DetectionHigh-resolution thermal conductivity detector (TCD)
Sample ThroughputUp to 147 positions (pneumatic/electronic/manual samplers)
Analysis Time~5 min per CN determination
Quantification Range0.002–20 mg C and N per sample
Accuracy<0.2% RSD (relative standard deviation)
Precision<0.1% RSD
Dual-Furnace SystemLeft & right furnaces, up to 1100 °C each
Separation Oven TemperatureUp to 110 °C
Carrier GasHelium
OxidantAutomated oxygen dosing
GC Column3 m packed capillary column
SoftwareEAS Clarity™ with linear/quad/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling
ComplianceDesigned for ASTM D5373, ISO 13878, USP <281>, and EN 15936 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 8040 CHNS-O Organic Elemental Analyzer
Measurement PrincipleDumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD)
Elemental RangeC, H, N, S, O (0.002–20 mg for C/H/N
Accuracy<0.2% (certified reference materials, purity >99.9%)
Precision<0.1% RSD (certified reference materials, purity >99.9%)
Combustion Temperatureup to 1100 °C
Reduction Oven Temperatureup to 110 °C
Carrier GasHelium
Oxygen DeliveryAutomated dosing with electronic flow control
GC Column0.8–4 m capillary or packed GC column (dedicated for CO₂, H₂O, N₂, SO₂ separation)
DetectorHigh-sensitivity, reference-free TCD
Sample ThroughputUp to 147 positions (pneumatic autosampler), 32/50/100 positions (electronic autosampler), manual option available
User InterfaceIntegrated touchscreen display
SoftwareEAS Clarity™ with linear/quadratic/cubic calibration, active recalibration, audit trail, and GLP-compliant data handling
Power ManagementStandby mode for reduced He/O₂ consumption and energy use
ComplianceDesigned to support ASTM D5291, ISO 16968, USP <28>, and FDA 21 CFR Part 11 requirements (when configured with full audit trail and electronic signature modules)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 4024 Classic CHNS-O Elemental Analyzer
Detection PrincipleFlash Combustion coupled with Gas Chromatographic Separation
Elements AnalyzedC, H, N, S, O
Detection Range200 ppm – 100%
Sample Mass0.01–100 mg (matrix-dependent)
Accuracy< 0.2% (vs. certified reference materials)
Precision< 0.1% RSD (vs. certified reference materials)
Combustion Furnace Temperature800–1100 °C
GC Column Temperature Range30–110 °C
TCD Limit of Quantification1–5 µg
Analysis Time15 min (CHNS), 3 min (CN, using 2-m GC column)
Auto-samplersPneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual
SoftwareEAS CLARITY for Windows
Gas RequirementsHe (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free dry compressed air
Dimensions760 × 350 × 700 mm (L×W×H)
Power Supply230 VAC ±10%, 1–10 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 8020 CHNS-O Organic Elemental Analyzer
Measurement PrincipleDumas combustion coupled with gas chromatographic separation and thermal conductivity detection (TCD)
Elemental ModesCHNS, CHN, CN, CNS, O
Sample TypesSolid and liquid
Sample Weight RangeC/H/N/S: 0.002–20 mg
O0.002–2 mg
Analysis TimeCHN: 5 min
CHNS10–25 min
O4 min
Accuracy<0.2% (certified reference materials, purity >99.9%)
Precision (RSD)<0.1%
Dual Combustion FurnacesMax. 1100 °C each
Separation Oven Temp.Up to 110 °C
Carrier GasHelium
Oxygen DeliveryIntegrated mass-flow controlled O₂ dosing
GC Column Length0.8–4 m
DetectorHigh-sensitivity TCD, reference-gas-free operation
AutosamplersPneumatic (147 positions), electronic (32/50/100 positions), manual
SoftwareEAS Clarity v.x.x with linear/quadratic/cubic calibration, active recalibration, audit trail, GLP-compliant data handling
ComplianceDesigned for ISO 17025, ASTM D5291, ASTM D7622, USP <28>, EN 15407, and FDA 21 CFR Part 11-ready configurations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 4010 Classic CHNS-O Elemental Analyzer
Detection PrincipleFlash Combustion coupled with Gas Chromatographic Separation
Elements AnalyzedC, H, N, S, O
Detection Range200 ppm – 100%
Sample Mass0.01–100 mg (matrix-dependent)
Accuracy< 0.2% (vs. certified reference materials)
Precision< 0.1% RSD (vs. certified reference materials)
Column Temperature Control30–110 °C (user-programmable)
Oxidation Reactor Temp800–1100 °C
Reduction Reactor Temp600–1100 °C
Analysis Time~15 min (CHNS), ~3 min (CN only, 2-m column)
DetectorThermal Conductivity Detector (TCD)
LOQ1–5 µg
Auto-samplersPneumatic (up to 147 positions), Electronic (32/50/100 positions), Manual
SoftwareEAS CLARITY v.x.x (Windows OS)
Gas RequirementsHe (99.999%, 3–5 bar), O₂ (99.999%, 3–5 bar), Oil-free Dry Compressed Air
Dimensions760 × 350 × 700 mm (L×W×H)
Power230 VAC ±10%, 1–10 A