Empowering Scientific Discovery

Beijing Lijia United Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
Model600LS
Measurement PrincipleVentilated Piezoresistive Pressure Transduction
Water Level Range0–9 m
Resolution0.001 m
Accuracy±0.003 m (0–3 m), ±0.018 m (3–9 m)
Temperature Range–5 to +60 °C
Temp. Resolution0.01 °C
Temp. Accuracy±0.15 °C
Conductivity Range0–100 mS/cm
Cond. Resolution0.001–0.1 mS/cm (range-dependent)
Cond. Accuracy±0.5% of reading + 0.001 mS/cm
Salinity Range0–70 ppt
Salinity Resolution0.01 ppt
Salinity Accuracy±1.0% of reading or ±0.1 ppt (whichever is greater)
Memory Capacity150,000 readings
Data Logging IntervalUser-programmable
Communication InterfaceSDI-12
Max Operating Depth9 m
Compatible PlatformsYSI 650MDS, YSI 6200 Data Collection System, third-party SDI-12 loggers
Added to wishlistRemoved from wishlist 0
Add to compare
OriginAustralia
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelStarflow
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
OriginUSA
ModelCR3000
Analog Input Channels28 single-ended (14 differential)
Analog Voltage Range±5000 mV
Analog Resolution0.33 µV
A/D Resolution16-bit
Maximum Scan Rate100 Hz
Pulse Count Channels4
Switched Excitation Outputs4 voltage, 3 current
Control Ports3 SDM, 8 I/O
Communication InterfacesCS I/O, RS-232, Ethernet (optional), RF radio (optional), CDMA/GPRS (optional), satellite (optional)
Supported ProtocolsPakBus, Modbus RTU/ASCII/TCP, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTP, NTCIP, SDI-12, SDM
Memory4 MB internal
Power Consumption2 mA (sleep), 3 mA (1 Hz), 10 mA (100 Hz)
Environmental ComplianceCE, EMC, GDT input protection
Real-Time ClockTemperature-compensated, battery-backed
Data Storage FormatTabular (timestamp + record number)
Operating Temperature0–40 °C
Software CompatibilityLoggerNet 3.4/4.0, PC400 1.2, ShortCut 2.2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
OriginUSA
ModelCR6
Processor32-bit ARM Cortex-M4 with hardware floating-point unit (100 MHz)
Internal Memory4 MB RAM, 6 MB flash for OS, 1 MB serial flash for program execution
MicroSD Card SupportUp to 16 GB
Real-Time Clock Accuracy±3 minutes/year (±10 µs with GPS synchronization)
USB InterfaceUSB 2.0 Full-Speed (12 Mbps), host/device capable
Ethernet10/100BASE-T
Communication ProtocolsPakBus, SDI-12, SDM, RS-232, RS-485, CPI (Campbell Peripheral Interface)
U-Port CapabilitiesSimultaneous analog/digital input, static vibration measurement (100 Hz – 6.5 kHz), bridge excitation (±2.5 V or ±2.5 mA), thermistor support (5 kΩ reference), frequency measurement up to 200 kHz
Analog Input12 single-ended or 6 differential channels
ranges±5000 mV, ±1000 mV, ±200 mV
Analog Output12-bit DAC (±2.5 V or ±2.5 mA)
Digital I/O12 configurable ports (3.3 V / 5 V logic)
Power Input12 V DC battery, solar (16–32 V DC), or USB
SW12V outputs2 × 12 V @ 1100 mA (20 °C)
Overvoltage ProtectionAll terminal strips include transient voltage suppression
Operating Temperature−25 °C to +50 °C (extended range options available)
Dimensions20.3 × 10.2 × 6.1 cm
Weight0.42 kg
ComplianceCE, FCC Part 15 Class B, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRinntech
OriginGermany
ModelARBOTOM®
TypePortable Acoustic Impulse Tomography System for In Situ Tree Health Assessment
Sensor Configuration2–24+ Adjustable Multifunctional Piezoelectric Sensors
Data OutputColor-Coded 2D Cross-Sectional & Optional 3D Volumetric Reconstructions
ComplianceDesigned for Field Deployment in Accordance with DIN EN 12512, ISO 12716, and ASTM D6248 (Non-Destructive Evaluation of Wood)
Software PlatformArborScan™ v5.x with Audit Trail, GLP-Compliant Reporting, and FDA 21 CFR Part 11–Ready Configuration Options
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSL-510-SS (Upward), SL-610-SS (Downward)
Sensitivity0.12 mV per W/m²
Calibration Factor8.5 W/m² per mV
Measurement Range−200 to +200 W/m² (net longwave)
Uncertainty±5% (k=2)
Spectral Range5–30 µm
Field of View150° (hemispherical)
Response Time<0.5 s
Zero Offset Drift<5 W/m²
Tilt Error<0.5%
Nonlinearity<1%
Long-Term Drift<2% per year
Repeatability<1%
Temperature Response<5% (−15 to +45 °C)
Thermistor30 kΩ @ 25 °C, ±1 °C accuracy
Thermistor Output0–2500 mV (with 2500 mV excitation)
Heater Power185 mW @ 12 V DC (780 Ω, 15.4 mA)
HousingAnodized aluminum, IP67 (SL-510-SS) / IP68 (SL-610-SS)
Cable ConnectorMarine-grade stainless steel, 30 cm pigtail
DimensionsØ23.5 mm × 27.5 mm height
Mass90 g (SL-510-SS), 100 g (SL-610-SS)
Warranty4 years
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
Model NumbersSP510
Measurement Range0–2000 W/m² (shortwave net radiation)
Spectral Range385–2105 nm (SP510), 295–2685 nm (SP610), 360–1120 nm (silicon photodiode models)
Output Options0–114 mV, 0–300 mV, 0–400 mV, 0–2.5 V, 4–20 mA, 0–5 V, USB, SDI-12
Uncertainty±5%
Cosine Response Error<30 W/m² at 80° zenith angle (SP510)
Response Time≤0.5 s (thermopile), <1 ms (silicon)
Operating Temperature−50 to +80 °C (thermopile), −40 to +70 °C (silicon, submersible to 30 m)
Long-Term Drift<2% per year
IP RatingIP68 (silicon models), IP67 (thermopile models)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSU-100
Spectral Range250–400 nm
Absolute Accuracy±10%
Uniformity±5%
Repeatability±1%
Output Sensitivity0.2 mV per μmol·m⁻²·s⁻¹
Full-Sun Output~35 mV (≈175 μmol·m⁻²·s⁻¹, ≈60 W·m⁻²)
Calibration Factor5.0 μmol·m⁻²·s⁻¹ per mV
Output Range0–60 mV (0–300 μmol·m⁻²·s⁻¹, 0–102 W·m⁻²)
Response Time<1 ms
Long-Term Drift<3% per year
Operating Environment−25 to +55 °C, 0–100% RH
IP RatingIP68 (submersible)
Weight75 g
Standard Cable Length5 m (extendable)
Power SupplySelf-powered (no external power required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandApogee
OriginUSA
ModelSN-500
Measurement Range (Shortwave Up)0–2000 W/m²
Measurement Range (Shortwave Down)0–2000 W/m²
Measurement Range (Longwave Up)−200 to +200 W/m²
Measurement Range (Longwave Down)−200 to +200 W/m²
Spectral Range (Shortwave Up)385–2105 nm
Spectral Range (Shortwave Down)295–2685 nm
Spectral Range (Longwave)5000–30,000 nm
Sensitivity55 µV/(W/m²) (SW↑), 150 µV/(W/m²) (SW↓), 100 µV/(W/m²) (LW↑/LW↓)
Response Time1 s (detector)
Zero Offset (5 K/h)18.2 W/m² (SW↑), 6.67 W/m² (SW↓), 10 W/m² (LW)
Field of View180° (SW↑), 150° (SW↓), 180° (LW↑/LW↓)
OutputFour SDI-12 digital channels (SW↑, SW↓, LW↑, LW↓)
Supply Voltage5–16 V DC (heater rated at 12 V DC)
Power Consumption62 mA / 740 mW @ 12 V DC
Operating Temperature−50 °C to +80 °C
Relative Humidity0–100 % RH
Dimensions116 mm (L) × 45 mm (W) × 66 mm (H)
Weight320 g (including mounting rod and 5-m cable)
Cable5-m, 4-conductor shielded twisted pair with ethylene propylene rubber jacket