| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APOGEE |
| Pricing | Available Upon Request |
| Wavelength Range | 350–1000 nm (PAR-NIR) / 300–850 nm (UV-PAR) |
| Dimensions | 15.5 × 9.5 × 4 cm (PAR-NIR), 15.5 × 11 × 8 cm (UV-PAR) |
| Weight | 500 g (PAR-NIR), 900 g (UV-PAR) |
| Detector | 2048-pixel linear CCD array (14 × 200 µm) |
| Spectral Resolution | 0.5 nm |
| Wavelength Repeatability | < 0.05 nm |
| Thermal Wavelength Drift | < 0.001 nm/°C |
| Integration Time | 4–6500 ms |
| Exposure Time | 4 µs–60 s |
| Dynamic Range | 1–4096 counts (±0.5%) |
| Signal-to-Noise Ratio | 1000:1 |
| Linearity Range | 0–2.1 AU (<0.5% deviation) |
| Power Input | +5 VDC, 220–250 mA |
| Optical Fiber Cable | 2 m, SMA-terminated |
| Cosine Corrector | Integrated, NIST-traceable calibration |
| Origin | Canada |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | TRAC |
| Pricing | Upon Request |
| Key | Origin: USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SQ-500 |
| Pricing | Available Upon Request |
| Spectral Range | 400–700 nm |
| Cosine Response Error | <2% (typical) |
| Temperature Drift | <0.1% per °C |
| Long-Term Drift | ≤1% per year |
| Sensitivity | 0.200 mV per µmol·m⁻²·s⁻¹ |
| Output Range | 0–1000 mV (0–5000 µmol·m⁻²·s⁻¹) |
| Operating Temperature | −40 to +55 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Submersible | Yes (IP68-rated housing) |
| Housing Material | Anodized aluminum body with acrylic diffuser |
| Dimensions | Ø24 mm × H27.5 mm |
| Cable | 3 m shielded, bare-wire termination (custom lengths available on order) |
| Calibration Interval | Recommended every 24 months |
| Warranty | 1 year limited |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Apogee O2S-F / O2S-D |
| Price | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SmartChem 200 |
| Price | €60,000 |
| Power Requirement | 90–250 VAC, 47–63 Hz, 300 W |
| Water Consumption | 2 mL per test |
| Operating Temperature | 18–30 °C |
| Relative Humidity | 20–85 % RH |
| Dimensions (H×W×D) | 42 × 65 × 100 cm |
| Weight | 65 kg |
| Sample Capacity | 126 positions across 5 racks |
| Sample Tube Size | up to 16 mm × 100 mm |
| Minimum Sample Volume | 3.0 µL (1 µL increment) |
| Reagent Volume | 3.0–300 µL (1 µL increment) |
| Dilution Factor | up to 100× |
| Reaction Cuvettes | 60-position rotating reusable disc, temperature-controlled at 37.0 ± 0.1 °C |
| Optical System | Dual-beam photometer with 8 narrow-band interference filters (420–880 nm), 6 V/10 W halogen lamp, 10 mm pathlength, linear range 0.001–2.500 Abs, resolution 0.0001 Abs |
| Throughput | up to 200 tests/hour |
| Detection Principle | Direct spectrophotometric measurement in discrete reaction cuvettes |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 907-0036, 911-0036 |
| Price | Upon Request |